General Characteristics

MONITOR

  • Electrocardiogram Monitor with LCD screen.
  • Electrocardiogram Signal acquired through 3 or 5 leads patient cable or through paddles
  • Leads selection:
    • with 3 leads cable: DI, DII, DIII.
    • with 5 leads cable: DI, DII, DIII, aVR, aVF, aVL and Precordial.
  • ECG waveform Cascade.
  • Digital indication of heart rate.
  • Low battery indicator.
  • Luminous indicator of Battery Charging.
  • Alarms Silence key.
  • Alarms for Heart Rate from 20 [1/min] to 250 [1/min].
  • ECG gain: 1/6, 1/4, 1/2, 1 y 2 [cm/mV].

DEFIBRILLATOR

  • Biphasic waveform.
  • Defibrillator use in three steps:
    1. Turn on and select energy.
    2. Charge.
    3. Trigger energy discharge by means of pushbuttons on the paddles or from keyboard.
  • Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70,100, 150 and 200 [Joules].
  • Visual and audible indication of charging process completed.
  • Stored energy indication on display.
  • Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
  • Charge is cancelled internally when: The key “Disarm” is pressed or when 60s have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF. In these cases the energy is discharged internally without reaching the paddles.
  • Direct or synchronized discharge.
  • Visual and audible indication of synchronized mode.
  • Discharge Capacity: 150 discharges at maximum energy, with fully charged internal battery.
  • Charger time to 200J: Less than 6s.

TEST OF ENERGY DELIVERED

RECORDER (Optional)

  • Direct access key for record command.
  • Automatic recording if occurs an event.
  • High resolution thermal array printer.
  • Recorder speed: 25mm/s.
  • Prints: Date and time, energy in Joules, Electrocardiogram waveform, Gain, Heart Rate, Lead, Sweep Speed, Pletismographics waveform, SpO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
  • Paper: Width: 50mm, Diameter Max: 45mm.

TRANSCUTANEOUS PACEMAKER (optional)

  • External stimulation through electrodes.
  • Frequency: 40bpm to 180bpm (adjustable in steps of 5bpm).
  • Current: 10mA to 200mA (adjustable in steps of 5mA).
  • Mode: Selectable, demand or asynchronous.
  • Pulse width: 20ms ± 5%.
  • Electrodes and elastic band set.

OXYGEN SATURATION (optional)

  • SpO2 measurement:
    • Range: 0% to 100%.
    • Precision:
      • Adult, ±2%, from 70 to 100%.
      • Neonatal, ±3% from 70 to 100%.
      • In Movement, ±3% from 70 to 100%.
  • Resolution: 1%
  • Percentual oxygen saturation alarm:
    • Upper limit: 1 → 100.
    • Lower limit: 0 → 99.
  • Pulse Rate and alarms measurement from 30 [1/min] to 250 [1/min] ±3 [1/min] and ±5 [1/min] with movement.
  • Resolution: 1 [1/min].
  • Pediatric or adult finger sensor.
  • SpO2 Extension cable.

 

THECNICAL SPECIFICATIONS

BASIC ACCESSORIES

  • Power input: 90Vac to 240Vac - 50/60Hz or 12 Vcc.
  • Rechargeable internal battery, NiMH-12 V, 3500 mAh
  • Power requirement: 180W (7W during standby).
  • Charging Time: 200 Joules less than 5 seconds.
  • Size: 295mm (width) x 200mm (height) x 345mm (length).
  • Weight: 6.0 Kg. (Including External paddles, battery and recorder)
  • Quality Standard:
    • CE marking, Dir. 93/42/CEE (certificate).
    • ISO9001 (certified).
    • ISO13485 (certified).
    • Disp. A.N.M.A.T. 3266/2013: B.P.F.
    • Disp. A.N.M.A.T. 2319/02
  • Safety Standard:
    • EN 60601-1 (Eq. IRAM 4220-1 and IEC 601-1).
    • EN-60601-1-2 (EMC)
    • EN 60601-1-6.
    • EN 60601-1-8.
    • EN 60601-2-4.
    • EN 60601-2-27.
    • EN 60601-2-49.
    • ISO 80601-2-61.
  • Authorized by A.N.M.A.T. PM-112515
Accessories Included:
  • External paddles for adults with coil cable.
  • Power cord for external +12Vcc power supply.
  • AC power cord.
  • 3 or 5 leads cable to patient for ECG.
  • Disposable electrodes.
  • User Manual.
  • Connection of internal paddles or to defibrillator patches.

USAGE ENVIRONMENTS

  • Ambulances, intensive care units, coronary units, operation theatres.
  • Easy to carry because of its reduced size and weight.

SPECIFICATIONS SUBJET TO CHANGE WITHOUT PRIOR NOTICE

Monitor defibrillator biphasic.pdf