Aggregate of sidestream capnography module + N2O + anesthetic gases for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of N2 O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

ACCESSORIES
Tubing straight airway adapter for sidestream capnography Feas Electrónica, quantity 2.
2.4 m CO2 samplig lines for sidestream capnography Feas Electrónica, quantity 2.
Water trap for use in sidestream capnography with anesthetic gases, quantity 2.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Battery module for LCD multiparmetric monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

BATTERY
14.4V / 8.8Ah Li-ion battery.
Autonomy: 4 hours.
Battery state indication (empty, full, on charge) on screen.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Agreggate 4 patient module for central monitoring station
This module allows you to expand your central monitoring station. When incorporated it will display 4 more beds in the same central.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Accessory to connect the oxygen inspired fraction (FiO2) sensor to the patient circuit. Exclusive use in Feas Electronica multiparametric monitor.

The T-Adapter is designed to be used in conjunction with the oxygen sensor (ref. 10101) in measurement systems of Inspired oxygen fraction (FiO2).

SPECS
T adapter, technical characteristics 22mm (inner diameter, outlet) x 15mm (inner diameter, T) x 22mm (outer diameter, inlet), HDPE material (High Density Polyethylene).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.