Energy test module for monophasic defibrillator 3850B
ARS 28,635.00 ARS 28,635.00 28635.0 ARS *
* El precio no incluye impuestos
ENERGY VERIFICATION DELIVERED:
The verification or energy test allows to ensure that the equipment is able to deliver energy on pallets or determine if there is a fault. This information is presented on the display of the device and, if it has a recorder (optional), it will record the information of the test result on paper.

If you are interested in buying, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.
Energy test module for biphasic defibrillator 3850B
ARS 28,635.00 ARS 28,635.00 28635.0 ARS *
* El precio no incluye impuestos
ENERGY VERIFICATION DELIVERED:
The verification or energy test allows to ensure that the equipment is able to deliver energy on pallets or determine if there is a fault. This information is presented on the display of the device and, if it has a recorder (optional), it will record the information of the test result on paper.

If you are interested in buying, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.
Adding module for 3850B Defibrillator
ARS 0.00 0.0 ARS *
* El precio no incluye impuestos
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.
Optional that can be added.

RECORDER
- Direct access key for record command.
- Automatic recording if an event occurs.
- High resolution thermal array printer.
- Registration speed: 25 mm/s.
- Prints: date and time, energy in joules, elctrocardiogram waveform, gain, heart rate, lead, sweep speed, plethysmographics waveform, SPO2, pulse rate, Mode: pacemaker rate, pacemaker current.
- Paper: width: 50 mm, maximum diameter: 45 mm.

TRANSCUTANEOUS PACEMAKER
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (adjustable in steps of 5 ppm).
- Current: 10 mA to 200 mA (adjustable in steps of 5 mA).
- Mode: Selectable, demand or asynchronous.
- Pulse width: 20 ms ± 5%.
- Electrodes and velcro belt.

OXYGEN SATURATION
SpO2 measurement:
- Range: 0% to 100%.
- Precision: Adult ±2%, from 70 to 100%. Neonatal ±3% from 70 to 100%. In movement ±3% from 70 to 100%.
- Resolution: 1%.
- Percentual oxygen saturation alarm: Upper limit: 1 to 100 and lower limit: 0 to 99.
- Pulse Rate and alarms measurement from 30 1/min to 250 1/min ±3 1/min and ±5 1/min with movement.
- Resolution: 1 1/min.
- Pediatric or adult finger sensor.