Biphasic 3850B Defibrillator Monitor

  • Country in which it would be used
  • Patient
  • Registrator
  • Pacemaker
  • Oxigen saturation
  • Electrocardiogram cable

344,750.00 344,750.00 344750.0 ARS

0.00

El precio no incluye impuestos

Esta combinación no existe.

ADD to chart

FEATURES
MONITOR
Electrocardiogram monitor with LCD screen.
Electrocardiogram signal acquired through 3 or 5 leads patient cable or through paddles.
Leads selection:
- With 3 leads cable: DI, DII, DIII and PAL.
- With 5 leads cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
ECG Gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
ECG waveform cascade.
Digital indication of heart rate.Low battery indicator.
Luminous Indicator of battery charging.
Alarms silence key.
Alarms for Heart Rate from 20 ppm to 250ppm.

DEFIBRILLATOR
Biphasic waveform.
Defibrillator use in three steps:
1- Turn on and select energy.
2- Load.
3- Trigger energy discharge by means of push buttons on paddles or from the keyboard.
Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules.
Visual and audible indication of charging process completed.
Stored energy indication on display.
Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
Charge is cancelled internally:When the key DISARM is pressed or when 60 seconds have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF.
In these cases the energy is discharged internally without reaching the paddles.
Direct or synchronized discharge.
Visual and audible indication of synchronized mode.
Discharge capacity: 150 discharges at maximum energy, with fully charged internal battery.
Charging time to 200 J, less than 6 seconds.
The equipment has a power test delivered.

RECORDER
Direct access key for record command.
Automatic recording if occurs an event.
High resolution thermal array printer.
Registration speed: 25 mm / s.
Prints: date and time, energy in joules, Elctrocardiogram waveform, Gain, Heart Rate, Lead, Sweep Speed, Plethysmographics waveform, SPO2, Pulse Rate, Mode: Pacemaker Rate, Pacemaker Current.
Paper: Width: 50 mm, Diameter Max: 45 mm.


OXYGEN SATURATION
SPO2 measurement:
- Range: 0 to 100%.
- Precision:
Adult ± 2% from 70% and 100%.
Neonatal: ± 3% from 70% and 100%.
In movement: ± 3% from 70% and 100%.
- Resolution: 1%.
- Percentual oxygen saturation alarm:
Upper limit: 1''100. Lower limit: 0''99.
- Pulse Rate and alarms measurement from 30[1/min] to 250 [1/min] ± 3[1/min] and ± 5 [1/min] with movement.
- Resolution: 1 [1/min].

TECHNICAL SPECIFICATIONS
Power input: 90Vac ~ to 240Vac - 50Hz/60Hz or 12 Vcc.
Rechargeable internal battery, NiMH - 12V, 3500 mAh.
Power requirement: 180 W (7W during standby).
Size: 295mm (width) x 200mm (height) x 345mm (length).
Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
Quality standards:
- CE Marking, Dir. 93/42 / EEC (certificate).
- ISO13485 (certificate).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.
Safety rules:
- EN 60601-1 (Eq IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (EMC).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-15.

INCLUDED ACCESSORIES
External paddles for adults with coil cable.
Power cable for external +12 power supply.
AC Power cord.
3 or 5 leads cable for patient for ECG.Disposable electrodes.
User's manual.

The image is illustrative.


  