LCD multiparametric monitor ECG/RESP/SpO2/1T/2T/NIBP

USD 2,700.00 2700.0 USD

2,700.00 $

Product not available

Add to Cart

FEATURES:
Menu, messages and instructions in English.
Single sweep speeds for circulatory and respiratory system: 12.5, 25 and 50 mm/s.
Visual and audible QRS indicator proceeding from ECG or Oxymeter.
When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
Three alarm levels: physiologicals, technicals and generals.
Upper and lower limits adjustable by the user.
Visual and audible alarm indicators, on screen and on top of the equipment.
Hotkey to activate the silent alarms for 2 minutes.
Alarms Turn Off.
User friendly menu by using the selector knob and hotkeys.
Waveform print-out on standard printer.
Analog outputs for ECG, RESP, IBP and a synchronization pulse.
Video output for slave or remote monitor (optional).
Networking Connection for Centralized Monitoring.
WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
Screen menu: normal, -7 leads of ECG, Tabular trends or graphical trends, frozen and measuring of calipers, large numbers.
CHANNELS
ELECTROCARDIOGRAM
Heart rate: 20 to 300 [1/min].
Gain selection: 1/4, 1/2, 1, 2 and 4 cm/mV, individual or for both channels.
Visual and audible QRS indication.
Automatic selection of 3 or 5 leads patient cable.
3 leads with 3 leads patient cable. Lead selection: DI, DII or DIII.
12 leads with 5 leads patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and V1, V2, V3, V4, V5 or V6.
50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
Heart rate alarms, minimum and maximum: 20 to 300 [1/min] and off.
Lead off detection.
Pacemaker pulse detection.
Pacemaker pulse rejection in counting the heart rate:
Pulse rejected characteristic:
Amplitude: from ±2 mV to ±700 Mv and pulse width: from 0.1 ms to 2.0 ms.
ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Detects and classifies the following arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy, Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
Store up to 32 events and allows review and printing.
Measurement of the S-T segment: both the isoelectric point and the ST point are user adjustable (J-point +60 ms or +80 ms, or any other value in ms, from 1 to 120 ms).
Range: ±2.00 mV.
OXYGEN SATURATION
Plethysmographic waveform with waveform gain adjustment x1/2, x1 and x2 and display of percentual oxygen saturation.
Measurement signal low perfusion and motion.
SPO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
Pulse rate:
Range: 20 to 300 [1/min].
Adult precision: ±3 [1/min].
Neonate precision: ±3 [1/min].
Motion precision: ±5 [1/min].
Resolution: 1 [1/min].
Alarm: 20 to 300 [1/min] and off.
RESPIRATORY WAVEFORM
Impedanciometric method.
Measurement selection: Transabdominal or Transtoraxic.
Respiratory rate: 5 to 170 [1/min].
Apnea Alarm.
Respiratory rate alarm, minimum and maximum: 5 to 170 [1/min] and off.
NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method
Use: ADULT or NEONATE.
Measurement mode: AUTOMATIC or MANUAL.
Measure unit: mmHg.
Resolution:
Pressure: 1 mmHg.
Pulse rate: 1 [1/min].
Transductor accuracy: ±3 mmHg.
Ranges:
PEDIATRIC/ADULT
Pressure: 10 to 255 mmHg - Pulse rate: 40 to 240 [1/min].
NEONATE
Pressure: 5 to 155 mmHg - Pulse rate: 40 to 240 [1/min].
Alarm limits of: Systolic pressure from 20 to 255 mmHg and off.
Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
Protections: Double protection from over-pressure.
Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
Protection for exceeding time of measurement.
TEMPERATURE
Up to 2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
Resolution: 0.1ºC. Accuracy: ±0.2ºC.
Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.
TECHNICHAL SPECIFICATIONS
15” LCD-TFT Color Monitor.
Resolution: 1024x768.
Greater angle of view.
Dimensions: Height: 345mm; Width: 335mm; Depth: 205mm.
Weight: 6Kg.
Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
Power Consumption: 60VA.
Quality Standard: ISO 13485 (Certified), Disp. A.N.M.A.T. 3266/2013: B.P.F. and Disp. A.N.M.A.T. 2319/02 (certified).
Safety Standard: UNE-EN60601-1.(Eq. IRAM 4220-1 and IEC 601-1) Electrical-shock protection: Class I - CF, UNE-EN60601-1-2 (Electromagnetic compatibility), certified. Authorized by A.N.M.A.T.: PM-1125-2.
INCLUDED:
3 or 5 leads patient cable.
Disposable electrodes.
SPO2 sensor.
SPO2 extension cable.
1 cuff for NIBP.
1 silicone hose for NIBP.
Intraesophageal / rectal temperature sensor Feás Electrónica - DB9M / G.
Power cord.
User manual.

The image is illustrative.


12 months warranty.