Patient Monitor, Multiparameter, Comen Model C30
The COMEN C30 Multi-Parameter Patient Monitor is the perfect device to meet all your portable monitoring needs in and out of the hospital. In addition, its hardness and quality allow it to withstand a 1.2 meter drop, making it an excellent portable device that meets the needs of all hospitals. Created for use in adult, pediatric and neonatal patients. It can provide users with all the basic monitoring parameters required by their patients.
Strong, stable, waterproof, dustproof, anti-drop and shockproof.
Small and light, easy to carry.
Suitable for emergency scene, out-of-hospital transport, intra-hospital transport, bedside monitoring in the emergency department

Model C-30
Technical specifications
Security
ISO 13485: 2003 Approved
CE marking according to MDD93 / 42 / EEC

Physical characteristics:
Dimensions: 190mmX81.6mmX107mm
weight: 1.2 kg

Operation Environment
Power: 15Vdc
Power supply: 100-250Vac, 50/60 Hz.
Temperature: 0-40 ° C
Humidity: 15-85%
Battery: Lithium-ion, rechargeable
Plug & play battery, capacity: 2600mA
Maximum of 6.5 hours for charging;
4 hours of continuous work

Specifications
Patient: adult, pediatric, neonate
Display: 4.3 "color TFT touch screen
Resolution: 16:9
2 curves on screen
Sweep speed: 12.5mm / s, 25mm / s, 50mm / s
Indicators:
• Battery indicator light
• Dual indicator alarm light
QRS beep and alarm sound
Key sound
AC input socket
MDR
Trend: 48 hours
Alarm: user adjustable high and low limits
Connection to the monitoring center
DVI connection

Breathing
Impedance method
Rate:
• Adult 0-1OOrpm
• Neonatal 0-150 rpm
• Resolution: ± 1 rpm
Apnea alarm: 10s-40s
Audible and visual alarm
Sweep speed: 12.5.25mm/s
Gain selection: x0.25, x0.5, x1, x2

ECG
Cable: 12-lead CardioTecTM,
3 or 5 snaps (selectable)
12 leads: I, Il, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, -V6
5 wire: RA, LA, RL, LL, V or R, L, N, F, C,
3 wire: RA, LA, LL or R, L, F
Lead Selection: 12 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
5 wire: I, Il, IIl, aVR, aVL, aVF, V
3 wire: I, Il, III
Gain selection: x0.25, x0.5, x1, x2, auto
Adult: 15-300 1 / min
Pediatric / neonate: 15-350 1 / min
Accuracy: ± 1% or ± 1 1 / min (whichever is greater)
Resolution: 1 1 / min
ECG bandwidth:
MON: 0.5-55Hz
DIA: 0.05-150 Hz
OPE: 1-20Hz
ST segment detection: ± 2.0mV (automatic)
Arrhythmia Analysis
Pacemaker pulse detection

Temperature
2 channels
Standard sensor: Cutaneous
Measurement range: 0-50 ° C
Resolution: 0.1 ° C
Accuracy: 0.1 ° C (excludes sensor error)
Channel: T1, T2, TD (temperature difference)

PNI
Measurement method: Automatic oscillometric
Working mode: manual / automatic / continuous
Interval: Adjustable from 1 min to 480 min
Measurement types: systolic, diastolic, mean
Unit of measure: mmHg / KPa, adjustable
Systolic pressure range:
• Adult: 40 to 270 mmHg
• Pediatric: 40 to 200mmHg
• Neonate: 40 to 135 mmHg
Diastolic pressure range:
• Adult: 10 to 215 mmHg
• Pediatric: 10 to 150mmHg
• Neonate: 10 to 100 mmHg
Medium pressure range:
• Adult: 20 to 235 mmHg
• Pediatric: 20 to 165mmHg
• Neonate: 20 to 110 mmHg
Overpressure Protection: Hardware and Software
• Accuracy: less than ± 5mmHg
• Resolution: 1mmHg

Sp02 Comen
Range: 1-100%
Resolution: 1%
Accuracy:
• ± 2% (70-100%, Ped, no movement)
• ± 3% (70-100%, Neo, no movement)
• 0-69% unspecified
Range alarm: 0-100%
Pulse Frequency:
• Range: 20 to 300 ppm
• Resolution: 1 ppm
• Accuracy:
- ± 3ppm (no movement)
- ± 5ppm (movement)
Alarm: 20 to 300 ppm

EtCO2
Sidestream CO2 (SideStream)
Range: 0 to 150 mmHg, 0 to 79%,
• 0 to 20 kPa (at 760 mmHg)
• Accuracy: ± 2mm Hg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Response time: <240 ms (10% to 90%)
Delay time: <2s

C02 COMEN Main Flow
Range: 0 to 150 mm Hg, 0 to 79%,
0 to 20 kPa (at 760 mmHg)

Accuracy: ± 2mmHg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Delay time: <2s

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Handle of pump door, infusion pump Sino MDT Ltd 1500H
Handle of pump door replacement, infusion pump Sino MDT Ltd 1500H.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Power selector switch, wired for Defibrillator 3850B Monophasic
Power selector switch, wired for Defibrillator 3850B Monophasic

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Energy selector key, cabled for defibrillator 3850B biphasic
Energy selector key, cabled for defibrillator 3850B biphasic

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
8F peelable hemostatic introducer, with needle and syringe
8F peelable hemostatic introducer, with needle and syringe

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Spike set for Enteral Nutrition Pump
Spike set for enteral nutrition pumps

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
AC inlet EMI/RFI filter 04SS3A-2SR-Q fused 4A-250VAC RoHS H&L corp-PN: 530040302014100
EMI/RFI filter 04SS3A-2SR-Q, 4A 250VAC-PN: 530040302014100

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermal paper roll holder for ECG Comen, model CM100 or CM300, diameter 14mm and length 88.7mm
Thermal paper roll holder for ECG Comen, model CM100 or CM300, diameter 14mm and length 88.7mm

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disk on module (DOM), 128MB IDE EDC 4000 40 pin vertical
The Innodisk vertical EDC 4000 adapts to any platform with an IDE connector and provides a quick and easy path upgrade. Designed for embedded industrial applications that require a quick boot process, the EDC 4000 efficiently updates the work environment and improves data transfer rates with read and write performances of up to 40MB and 20MB per second, respectively. The vertical EDC 4000 has 128MB capacity and 40-pin vertical connector packages.

The integrated disk card is a replacement for the central monitoring station.

Months Warranty: 3

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Set of 4 limb clamps electrodes, adult for ECG Comen, model CM100 or CM300, 040-000143-00
Set of 4 limb clamps electrodes, adult for ECG Comen, model CM100 or CM300, 040-000143-00

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Rotary opto encoder 16 position (trim knob) 61C Series
16-position rotary optical encoder or rotary knob for menu access on monitors Mod. Multipar from Feas Electrónica.
High reliability, with push button for Enter key or data confirmation16-position rotary optical encoder or rotary knob for menu access on monitors Mod. Multipar from Feas Electrónica.
High reliability, with push button for Enter key or data confirmation


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Cable to patient with Din 3.0mm for electrocardiograph (ECG) brand (Dong Jiang), model 11B
PRODUCT DESCRIPTION
Cable to patient with Din 3.0mm for electrocardiograph brand (Dong Jiang) model 11B
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / 10 Lead Cable / ECG Cable / EKG Cable

FREQUENT QUESTIONS
What places do you ship to? We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Analog interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamics Polygraph / SpO2 / PNI
Analog interconnection cable between CPU and Electrophysiology and Hemodynamics Polygraph preamplifier / SpO2 / PNI
The length of the cable is adaptable to the installation, with lengths of 5, 8, 9 and 10 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer adapter cable (DB9/G) to BD transducer
Pressure transducer adapter cable (DB9/G) to BD transducer

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (33-47cm), reusable, large adult, 1 via, Feas Electrónica
One-way reusable Handle/Cuff for non-invasive blood pressurre measurement.
Size: 35,5 to 46 cm in circunference.
With hose connector included.
For adult patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
KNF Pump model NMP05L 6V DC SF948
Replacement suction pump for CO2 Modules, in multiparameter monitors. Exclusive use in Feas Electronic´s multiparameter monitor, with Optional CO2 Side Stream, brand Feas Electronica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Syringe infusion pump model SN-50C66T: one channel, standard support, with weight mode
Syringe infusion pump model SN-50C66T is a constant volume, channel and speed controlled infusion pump. It is characterized by high precision, stable flow rate and low dosage.

It is used particularly for the infusion of sodium nitroprusside, dopamine, propofol and antibiotics for acute and serious illnesses. The pump has multiple types of alarm functions to ensure a safe and reliable infusion process.

This product is used to clinically control the flow and velocity of fluids (drugs, nutrients, and blood) infused into the patient's body for safer use.

GENERAL CHARACTERISTICS
* The equipment can store customized syringe information from 33 different manufacturers, Weigao and 32 other manufacturers, configurable by the user.
* SN-50C66T pump can use sterile and disposable syringes of 5ml, 10ml, 20ml, 30ml or 50ml. Automatically recognizes the syringe in place.
* The equipment can store up to 2000 historical infusion records, which include the following information: injection mode, injection rate, alarm information, total volume injected, threshold value of the occlusion pressure limit of the path, limiting quantity, number of syringe and information of the operation.
* It has the following alarm functions:
Incorrect position of the syringe.
Residual limit.
Occlusion.
End of injection.
No operation.
From empty syringe.
Flow limit exceeded.
Plunger decoupled.
Power cord disconnected.
Discharged battery.
Dead battery.
System error.
* Battery operating time: starting from a full charge, the battery can support 6 hours of operation on one channel at a rate of 5 ml / h.
* Allows operation and battery charging from the car's 12Vdc connector.
* Intended User: Adult, Pediatric, Neonatal

TECHNICAL SPECIFICATIONS
* Dimensions:
306mm x 140mm x 146mm (Length x Width x Height)
* Weight: 2.25kg (includes support).
* Electrical feeding:
AC input: 100V to 240V, 50/60 Hz.
DC input: 12Vdc.
Battery voltage: 12Vdc.
Nominal power: 40 VA.

CERTIFICATES:
* Quality standards:
ISO13485
Disp. A.N.M.A.T. 3266/2013: B.P.F.
Disp. A.N.M.A.T. 2319/02
* Safety rules:
UNE-EN 60601-1. (Eq. IRAM 4220-1 and IEC 601-1), Class I - Prot. Desc. Elect .: CF
UNE-EN 60601-1-2 (Electromagnetic Compatibility).
Authorized by the A.N.M.A.T .: PM 1125-18.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.