Neonatal oximeter sensor DB9M/G Feas Electrónica 3026
Neonatal oximeter sensor DB9M/G Feas Electronica 3026.

This sensor is used in oximetry monitoring systems to non-invasively determine Percent Oxygen Saturation (SpO2), pulse rate, and pulse plethysmographic waves.
Its use is indicated for patients of less than 3kg.

It has a length of 40 cm.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermoformed, mechanized and milled plastic paddle holder for Defibrillator 3850B
Thermoformed, mechanized and milled plastic paddle holder for 3850B Defibrillator.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Biphasic for simulation, Feas Electrónica
Simulation defibrillator. DOES NOT DISCHARGE ENERGY.

CHARACTERISTICS MONITOR
- Electrocardiogram monitor with LCD screen.
- Electrocardiogram signal acquired by cable to patient or by paddles.
- Derivations:
- With 3-pin cable: DI, DII, DIII and PAL.
- With 5-pin cable : DI, DII, DIII, aVR, aVF, aVL, Precordial and PAL.
- Cascade electrocardiogram.
- Digital indication of heart rate.
- Low battery indicator.
- Battery charge indicator light.
- Alarm silence key.
- Heart rate alarms from 20 [1/min] to 250 [1/min].
- ECG gain: 1/6, 1/4,1/2, 1 and 2 [cm/mV].

DEFIBRILLATOR
- Use of the defibrillator in three steps:
1. Power on and power selection.
2. Charge.
3. Energy release by means of pushbuttons on paddles or from the keyboard.
- Step load selection key: 2, 3, 5, 7, 10, 20, 50,100, 200, 300 and 360 [Joules].
- Audible and visual indication of end of charge.
- Indication on display of stored energy.
- Energy Trigger by simultaneously pressing both paddle pushbuttons or the “SHOCK” key.
- Internal charge cancellation:
Occurs when the "CANCEL CHARGE" key is pressed or when 60 seconds elapse from the end of the energy charge or when the energy selector key is turned to the "MONITOR" or "OFF" position.
- It does not perform downloads but can, for the simulation, be configured as free or synchronized.
- Audible and visual indication of synchronous mode.

RECORDER
- Direct registration key.
- Automatic registration before an event.
- High resolution thermal recorder.
- Registration speed: 25 mm/s.
- Prints: Date and time, energy in Joules, Electrocardiogram curve, Gain, Heart rate, Lead, Sweep Speed, Plethysmographic curve, SpO2, Pulse Rate, Mode, Pace Rate, Pace Current.
- Paper: Width of 50 mm, Maximun diameter of 45 mm.

TRANSCUTANEOUS PACEMAKER
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (Selectable in steps of 5 ppm).
- Current: 10 mA to 200 mA. (Selectable in 5 mA steps).
- Mode: Selectable, on demand of fixed.
- Pulse width: 20 ms ± 5%.

OXYGEN SATURATION (SpO2)
- SpO2 measurement:
- Range 0% a 100%.
- Accuracy:
Adult ±2% between 70% and 100%.
Neonatal ±3% between 70% and 100%.
Moving ±3% between 70% and 100%.
- Resolution: 1%.
- Percentage oxygen saturation alarm:
Upper limit: from 1 to 100.
Lower limit: from 0 to 99.
- Measurement of pulse rate and alarms from 30 to 250 [1/min] ±3 [1/min] and ±5 [1/min] in Movement.
- Resolution: 1 [1/min].

TECHNICAL SPECIFICATIONS
- Supply voltage: 90 Vca a 240 Vca - 50 Hz/60 Hz, or 12 Vcc.
- Internal rechargeable NiMh battery - 12 V, 3500 mAh.
- Consumption: 10 W.
- Size: 295mm (width) x 200mm (height) x 345mm (depth).
- Weight: 5 Kg (Including external paddles, battery and recorder).

ACCESSORIES INCLUDED
- 1 Set of external padles for adults with spiral cable.
- 1 Power cable for external +12 Vdc input.
- 1 Power line cable.
- 1 Patient cable with 3 clips or 5clips for ECG.
- 10 disposable electrodes.
- 1 User Manual.
- 1 Set of electrodes and 1 elastic belt.
- 1 roll of 50 mm paper.
- 1 Oximetry clamp sensor, adult or pediatric.
- 1 Oximetry sensor extension.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - Defibrillator 3850B
RENT
Includes equipment rental. For different rental periods, please consult.

Feas Electronica Model 3850B Biphasic is an external defibrillator monitor with a rectilinear biphasic waveform of up to 200J, selectable in steps, which allows defibrillation in asynchronous or synchronized mode with the R wave of the patient's ECG for the application of synchronized cardioversion.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow monitoring of heart rate, SpO2 value and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, it can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and optionally the plethysmographic curve, manually when the operator decides or automatically during charging.

FEATURES

MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired through 3 or 5 leads patient cable or through paddles.
• Leads selection:
- With 3 lead cable: DI, DII, DIII and PAL.
- With 5 lead cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
• ECG Gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
• ECG waveform cascade.
• Digital indication of heart rate.
• Low battery indicator.
• Luminous Indicator of battery charging.
• Alarms silence key.
• Alarms for Heart Rate from 20 ppm to 250ppm.

DEFIBRILLATOR
• Biphasic waveform.
• Defibrillator use in three steps:
1- Turn on and select energy.
2- Load.
3- Trigger energy discharge by means of push buttons on paddles or from the keyboard.
• Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules.
• Visual and audible indication of charging process completed.
• Stored energy indication on display.
• Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
• Charge is cancelled internally: When the key DISARM is pressed or when 60 seconds have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF.
In these cases the energy is discharged internally without reaching the paddles.
• Direct or synchronized discharge.
• Visual and audible indication of synchronized mode.
• Discharge capacity: 150 discharges at maximum energy, with fully charged internal battery.
• Charging time to 200 J, less than 6 seconds.
• The equipment has a power test delivered.

RECORDER (OPTIONAL)
• Direct access key for record command.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal array printer.
• Registration speed: 25 mm / s.
• Prints: date and time, energy in joules, Elctrocardiogram waveform, Gain, Heart Rate, Lead, Sweep Speed, Plethysmographics waveform, SPO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: Width: 50 mm and Diameter Max: 45 mm.
Accessory Included:
50 millimeter roll of paper.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SPO2 measurement:
• Range: 0 to 100%.
• Precision:
Adult ± 2% from 70% and 100%.
Neonatal: ± 3% from 70% and 100%.
In movement: ± 3% from 70% and 100%.
• Resolution: 1%.
• Percentual oxygen saturation alarm:
Upper limit: 1 to100.
Lower limit: 0 to 99.
• Pulse Rate and alarms measurement from 30[1/min] to 250 [1/min] ± 3[1/min] and ± 5 [1/min] with movement.
• Resolution: 1 [1/min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm (selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA (selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

TECHNICAL SPECIFICATIONS
• Power input: 90Vac ~ to 240Vac - 50Hz/60Hz or 12 Vcc.
• Rechargeable internal battery, NiMH - 12V, 3500 mAh.
• Power requirement: 180 W (7W during standby).
• Size: 295mm (width) x 200mm (height) x 345mm (length).
• Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
• Quality standards:
- CE Marking, Dir. 93/42 / EEC (certificate).
- ISO13485 (certificate).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.
• Safety rules:
- EN 60601-1 (Eq IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (EMC).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-15.

INCLUDED ACCESSORIES
External paddles for adults and pediatric with coil cable.
Power cable for external +12 power supply.
AC Power cord.
3 or 5 wire cable for patient for ECG.
Disposable electrodes.
User's manual.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of pacemaker module for Desfibrillator 3850B
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

TRANSCUTANEOUS PACEMAKER
- Pacemaker electrode output: Type CF.
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (adjustable in steps of 5 ppm).
- Current: 10 mA to 200 mA (adjustable in steps of 5 mA).
- Mode: Selectable, demand or asynchronous.
- Pulse width: 20 ms ± 5%.
- Frequency Accuracy: Within ±5% of displayed value.
-Pacemaker current accuracy: From 10mA to 45mA is ±5mA.
From 50 mA to 200mA is 10%
-Refractory period: 340 ms for frequencies less than or equal to 80 ppm, 240 ms for frequencies greater than 80 ppm.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Recorder module for Desfibrillator 3850B
RECORDER
- Registration hotkey.
- High resolution thermal array printer.
-Resolution
Y axis: 8 points per mm.
X axis: 16 points per mm.
- Paper: width: 50 mm, maximum diameter: 45 mm.
-Printing width: 48 mm.
- Registration speed: 25 mm/s.
- Records the type of patient, the date, the time and in real time, 1 or 2 curves: electrocardiogram and percentage oxygen saturation or cascade electrocardiogram.
-A 50mm x 25m roll of thermal paper is delivered for the UC50 recorder


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of blood oxygen saturation module for Desfibrillator 3850B
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
- SpO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
- Pulse rate:
Range: 20 to 300 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

ACCESSORIES
SpO2 sensor, quantity 1.
SpO2 extension cable, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.