Lingual oximeter sensor DB9F for veterinary use Feas Electrónica
Lingual sensor, reusable clip type, for the non-invasive measurement of blood oxygen saturation of veterinary patients. It allows to visualize the oxygen saturation (SpO2), the pulse frequency and the plestographic curve. Exclusive use in Feas Electronica multi-parameter monitor , under supervision of trained staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A

This oximetry sensor is used for adult patients (weighing more than 30 kg) to measure arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Oxygen sensor for FiO2, Feas Electrónica
Sensor used for the measurement of Fraction inspired by oxygen, this measurement is carried out by an electrochemical cell which useful life is of 2 years from the moment of its opening.

The Feas Electrónica O2 sensor is designed as an oxygen sensing element of the Multipar LCD and PM9000 Feas Electrónica Patient Monitor models and measures the oxygen concentration in gas mixtures breathed by the patient.
Use is limited to system monitoring and should be used only by qualified personnel.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mainstream Capnography sensor, Feas Electrónica
The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injection temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adapter clips for veterinary multiparametric monitor patient cable
Adapter clips for veterinary multiparametric monitor patient cable

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PS2 Mouse for Feas Electrónica equipment
Mouse for Feas Electrónica equipment

The mouse should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405, Polygraph for Hemodynamics studies model 1405 and Model 5032C Monitoring Center. The user is responsible for ensuring compatibility between the mouse and the computer.

Cable length: 1.5 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, Modular, Comen, Model C90 + C30
COMEN C90 is a device designed to meet the most advanced needs for room monitoring, intermediate care, intensive care, among others. Created to be used in adult, pediatric and neonatal patients. Able to improve in its benefits, according to the needs of the user and the complexity of its clinical unit. This is due to the use of modules for the different extended functions that are required by clinicians.
Features
• It has a C30 multiparameter module, removable and usable as transfer equipment.
• Large high resolution touch screen
• For highly complex monitoring

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used on animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 12,1", Comen, with Batery Li ion include, Touch screen, light, model C80
MULTIPARAMETER MONITOR C80

C80 provides the clinician with advanced functionality and monitoring options to meet the demands of a wide range of care in any hospital setting.
It has a color screen with TFT technology of 10.4" inclined to facilitate observation.
Easy menu use via rotary knob and touch screen.
In addition, it has reserved expansion ports such as for SD card, USB port and network.

Adult, Pediatric, Neonatal Use

ELECTROCARDIOGRAM(ECG)
Heart rate:
•Adult: 15-300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Accuracy: ±1% o ±1 [1/min], whichever is greater.
Resolution: ±1 [1/min]
Gain selection: 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 40mm/mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12 lead ECG input mode.
Selection of leads:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF y V
3. DI, DII, DIII, aVR, aVL, aVF y V1 a V6
Frequency response:
•Monitoring mode: 0.5-40Hz.
•Deagnostic mode: 0.05-130Hz.
•Surgery modality: 1-20Hz.
•ST Mode: 0.05-40hZ.
Heart rate alarms:
•Adult: 15 - 300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ±2mV~±700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia type: PVC, Asystoloe, VTac, Tachycardia, Ventricular tachycardia, Supraventricular tachycardia, VR, Bigeminia, Trigeminia, R on T, Bradycardia, Ventricular bradycardia, missed beats, Atrial fibrillation, Ventricular fibrillation, Non-captured pacemaker (NCP), Non-captured pacemaker (PNP).
ST segment analysis:
Range: -2mV to +2mV
Accuracy: Measurement tolerance within (-0.8 mV)-(+0.8 mV) is ±0.02 mV or ±10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curse, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
Comen SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, the tolerance is ±2% (without movement).
Neonatal Accuracy: within 70% -100%, the tolerance is ±3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE RATE
Comen SpO2:
Range: 20 - 254 [1/min]
Resolution: 1[1/min]
Accuracy: ±2 [1/min]
Alarm: 20 a 350 [1/min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Within 7 [1/min] – 150 [1/min], the measurement error is ±2 rpm or ±2%, whichever is greater.
The tolerance is not defined by other ranges.
Alarm Limit Specification:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscillometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Measurement unit: mmHg
Nominal Monitoring Range:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Alarm Limit Specifications:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric Range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Precision:
The mean error should be less than 5mmHg
The standard deviation should be less than 8mmHg.
Manual or automatic start of measurement at programmable intervals of 1/ 2/ 2.5/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 180/ 240/ 480/ 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
•Adult: When the cuff pressure exceeds 297 mmHg ±3mmHg, the control valve will relieve the pressure.
•Child: When the cuff pressure exceeds 240 mmHg ±3 mmHg, the control valve will relieve the pressure.
•Neonate: When the cuff pressure exceeds 147 mmHg ±3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement Method: direct.
A temperature channel.
Temperature Ranges
Range: 0 - 50° C
Accuracy: ±0.1°C (Exclusive of probe tolerance)
Resolution: 0.1°C
Maximum and minimum temperature alarms:
Range: 0 - 50° C


TECHNICAL SPECIFICATIONS

12.1" color touch screen with TFT technology Resolution: 800 X 600
Inclined screen to facilitate observation.
Dimensions: 344 mm x 291 mm x 165 mm
Weight 3.9 Kg. with battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 – 240 Vac, 50/60 Hz.
C80: Standard: Li-Ion 11.8V/2200mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60VA
Reserved expansion ports such as SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 10,4", Comen, With Batery Li ion include, Touch screen, Light, model C50
C50 PATIENT MONITOR

C50 provides the physician with advanced functionalities and monitoring options in order to meet the demands of a wide range of care in any hospital environment.
It has a 10.4 "" color screen with TFT technology included to facilitate observation.
Easy use of the menu via rotary knob and touch screen.
In addition, it has reserved expansion ports for SD card, USB port and network.

Use Adult, Pediatric, Neonatal

ELECTROCARDIOGRAM (ECG)
Heart rate:
• Adult: 15-300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Accuracy: ± 1% or ± 1 [1 / min], whichever is greater.
Resolution: ± 1 [1 / min]
Gain selection: 1.25mm / mV, 2.5mm / mV, 5.0mm / mV, 10mm / mV, 40mm / mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12-lead ECG input mode.
Lead selection:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF and V
3. DI, DII, DIII, aVR, aVL, aVF and V1 to V6
Frequency response:
• Monitoring mode: 0.5-40Hz.
• Diagnostic mode: 0.05-130Hz.
• Surgery mode: 1-20Hz.
• ST mode: 0.05-40hZ.
Heart rate alarms:
• Adult: 15 - 300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ± 2mV ~ ± 700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia Type: PVC, Asystole, VTac, Tachycardia, Ventricular Tachycardia, Supraventricular Tachycardia, VR, Bigemine, Trigemine, R over T, Bradycardia, Ventricular Bradycardia, Missed Beats, Atrial Fibrillation, Ventricular Fibrillation, Pacemaker Not Captured (PNC) Pacemaker does not dial (PNP).
ST segment analysis:
Range: -2mV to + 2mV
Accuracy: Measurement tolerance within (-0.8 mV) - (+ 0.8 mV) is ± 0.02 mV or ± 10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curve, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
COMEN SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, tolerance is ± 2% (no movement).
Neonatal Accuracy: Within 70% -100%, tolerance is ± 3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE FREQUENCY
COMEN SpO2:
Range: 20 - 254 [1 / min]
Resolution: 1 [1 / min]
Accuracy: ± 2 [1 / min]
Alarm: 20 to 350 [1 / min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child/neonate: 0 to 150 [1 / min]
Within 7 [1 / min] - 150 [1 / min], the measurement error is ± 2 rpm or ± 2%, whichever is greater.
Tolerance is not defined by other ranges.
Alarm limit specifications:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child / neonate: 0 to 150 [1 / min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscilometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Unit of measure: mmHg
Nominal monitoring range:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Medium: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40 - 200 mmHg,
Diastolic: 10 - 150 mmHg,
Medium: 20 - 165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Medium: 20 - 110 mmHg
Alarm limit specifications:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Media: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40-200 mmHg,
Diastolic: 10 - 150 mmHg,
Media: 20-165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Media: 20 - 110 mmHg
Precision:
The mean error must be less than 5 mmHg
The standard deviation must be less than 8 mmHg.
Manual or automatic start of measurement at programmable intervals of 1/2 / 2.5 / 3/4/5/10/15/30/60/90/120/180/240/480 / 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
• Adult: When the cuff pressure exceeds 297 mmHg ± 3mmHg, the control valve will relieve the pressure.
• Child: When the cuff pressure exceeds 240 mmHg ± 3 mmHg, the control valve will relieve the pressure.
• Neonate: When the cuff pressure exceeds 147 mmHg ± 3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement method: direct.
A temperature channel.
Temperature ranges
Range: 0 - 50 ° C
Accuracy: ± 0.1 ° C (probe tolerance only)
Resolution: 0.1 ° C
Maximum and minimum temperature alarms:
Range: 0 - 50 ° C

TECHNICAL SPECIFICATIONS
10.4 "color touch screen with TFT technology Resolution: 800 X 600
Tilted screen for easy observation.
Dimensions: 291.7mm x 250mm x 146.5mm
Weight 3.3 Kg. With battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 - 240 Vac, 50/60 Hz.
C50: Standard: Li-Ion 11.8 V / 2200 mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60 VA

Reserved expansion ports for SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used in animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Bracket for Feas Electrónica LCD multiparametric monitor
Bracket to securely hold the Feas Electronica multiparameter monitor. Allows the equipment to be rotated horizontally to both sides. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Articulated wall bracket for Feas Electrónica LCD multiparametric monitor
Articulated bracket to securely sustain a Feas Electronica multiparametric monitor. It has several degrees of freedom, since it allows the equipment to be rotated in a horizontal direction, on both sides and inclined anteriorly and posteriorly. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Silicone hose for NIBP, 3m length
Silicone hose to be connected at one end of the cuff used for non-invasive pressure measurement and at the other end to be connected to the multiparametric monitor. Its length is 3 meters, making it easy to carry out the measurement remotely to the equipment.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient line of 2,4 m for sidestream Capnography, Feas Electrónica
Disposable accessory to connect the 'T' type nozzle (which joins the respirator and the patient) to the monitoring system. Its extension is 2,4 meters. The use is exclusive for each patient, in Feas Electronica multiparametric monitor.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Feas Electrónica Sidestream CO2 Filter Kit
Composed by:
1 humidity filter for sidestream capnography, Feas Electrónica
and two 13mm filters for sidestream capnography, Feas Electrónica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Filters kit of 13mm for sidestream capnography Feas Electrónica
Pair of filters to be used in sidestream capnography of Feas Electronica multiparametric monitors. The filters prevent the entry of particles to the components of the measurement system.
13 mm filter.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Installation and start-up of the Monitoring Center
It consists of carrying out the installation of the monitoring center and the connection with the Feas Electronica brand patient monitors.
Solenoid valve, Koge KSV05B
Solenoid valve, Koge KSV05B

Maximum current: <60 mA
Escape velocity: <6 seconds
Tightness: 3.0 mmHg / min
Maximum pressure: 300mmHg
Applications: blood pressure monitor, etc.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable electrodes x 10 units
Disposable electrodes x 10 units
For patient cable.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Calibration and Certificates of Equipment Calibration
This service includes the calibration of the equipment sent and the certification that the equipment is calibrated according to calibrated simulators and analyzers, both traceable to international standards.
If the equipment is not in conditions to be certified, we cannot issue the corresponding certificate. In that case the necessary repair of the equipment will be quoted to ensure the correct operation of the equipment, so it can be certified. Only if it is approved and a correct operation is achieved, certification will be carried out.