Installation and start-up of the Monitoring Center
It consists of carrying out the installation of the monitoring center and the connection with the Feas Electronica brand patient monitors.
Interconnection cable between Multipar and installation of Central Monitoring Station (DB9F-DB9F)
Cable to connect the multiparameter monitor to a wall connector of the installation of a Monitoring Central. They have a length of 1.5m and at both ends it has 1 female DB9 connector.
For use in multi-parameter monitors of Feas Electrónica brand, exclusively.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Intraesophageal/rectal temperature sensor DB9M/G Feas Electrónica
Feas Electrónica Intraesophageal/rectal temperature sensor DB9M/G

The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
KNF Pump model NMP05L 6V DC SF948
Replacement suction pump for CO2 Modules, in multiparameter monitors. Exclusive use in Feas Electronic´s multiparameter monitor, with Optional CO2 Side Stream, brand Feas Electronica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Lingual oximeter sensor DB9F for veterinary use Feas Electrónica
Lingual sensor, reusable clip type, for the non-invasive measurement of blood oxygen saturation of veterinary patients. It allows to visualize the oxygen saturation (SpO2), the pulse frequency and the plestographic curve. Exclusive use in Feas Electronica multi-parameter monitor , under supervision of trained staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mainstream Capnography sensor, Feas Electrónica
The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injection temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monitoring central station model 5032C Feas Electrónica
The Monitoring central station model 5032C Feas Electronica is a centralized patient monitoring system, composed of a Central Processing Unit (CPU) with CENTRALC software, a color LCD monitor, a keyboard, a mouse, a printer and the necessary wiring for the communication with bedside devices. The Monitoring Central allows monitoring from 4 to 16 patients, through the connection with bedside monitors. Monitors supported include, but are not limited to, the following devices: LCD Multipair Patient Monitor, Defibrillator Monitor 3850B, and FEAS ELECTRONICA Vital Signs Monitors. The connection between the Bedside Monitor and the Monitoring Center allows communication which can be: Analog, Digital and Full Digital.

- Provides simultaneous monitoring of electrocardiogram with indication of heart rate, respiratory curve with indication of respiratory rate and invasive pressure curve, with indication of systolic, diastolic and mean pressure values of up to 16 different patients.
- Ideal for use in intensive care and coronary units.
- Observation of Waveforms: electrocardiogram, invasive blood pressure and respiratory.
- Digital communicaton with bedside feas ELECTRONICA monitors, for the reception of values of: ECG, Respiratory, SpO2, Pulse Rate, EtCO2, Invasive Blood Pressure, Temperature, Non-Invasive Blood Pressure, Fico, and Respiratory Rate.
- Selection of ECG and RESPIRATORY curve gains.
- Auto scale invasive pressure curve.
- Curve sweep speed selection.
- Audible and visual alarms by maximum and minimum, configurable for all the parameters; with volume control.
- Enter text on screen (Patient Case History).
- Freeze waveform of selected patient.
- Observe previous events.
- Trend graphs. Graphic or tabular trend of the last 72 hours, displayed on 1, 4, 8, 12, 24, 48 and 72 hours.
- High resolution printing of: saved waveforms and values for heart rate, systolic, diastolic and mean pressures, respiratory rate and trends for all the parameters.

TECHNICAL SPECIFICATIONS

Analogic Input Signals:
- ECG: 1V/mV.
- PRESSURES: 1V/100 mmHg.
- RESPIRATORY: 1V/3 Ohm.

Digital connection to bedside monitors:
- Display: Color SVGA Monitor Dimensions: 19" (Optional large size).
- CPU: Industrial PC Motherboard. Storage Solid State Disk.
- Output for connecting additional remote monitors.
- Printer: Laser black and white.
- AC Voltge input: 90V-/240V. ~ Frequency 50Hz/60Hz.

ACCESSORIES INCLUDED
- Keyboard, mouse and pad.
- Power cords for CPU, monitor and printer.
- User manual.

AREAS OF USE:
Intensive and intermediate care units, coronary care units, operating rooms, rehabilitation centers, others.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - LCD Multiparameter Patient Monitor ECG/RESP/SPO2/PNI
Includes equipment rental. For different rental periods, please consult

Feas Electrónica MULTIPAR LCD Patient Monitor is designed for monitoring the vital signs of patients in Intensive Therapies, Coronary Units, Operating Rooms, Emergency Rooms, and in a wide variety of clinical-hospital environments, where several vital signs need to be monitored of a patient simultaneously.

GENERAL CHARACTERISTICS
FUNCTIONS:
• Menu, messages and instructions in English.
• Single sweep speeds for circulatory and respiratory system: 12.5, 25 and 50 mm/s.
• Visual and audible QRS indicator proceeding from ECG or Oxymeter.
• When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
• Three alarm levels: physiologicals, technicals and generals.
• Upper and lower limits adjustable by the user.
• Visual and audible alarm indicators, on screen and on top of the equipment.
• Hotkey to activate the silent alarms for 2 minutes.
• Alarms Turn Off.
• User friendly menu by using the selector knob and hotkeys.
• Waveform print-out on standard printer.
• Analog outputs for ECG, RESP, IBP and a synchronization pulse.
• Networking Connection for Centralized Monitoring.
• WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
• Screen menu: normal, 7 leads of ECG, Tabular trends or graphical trends, frozen and measuring of calipers, large numbers.

BASIC CHANNELS
ELECTROCARDIOGRAM
• Heart rate: 20 to 300 1/min.
• Gain selection: 1/4, 1/2, 1, 2 and 4 cm/mV, individual or for both channels.
Visual and audible QRS indication.
Automatic selection of 3 or 5 leads patient cable.
• 3 leads with 3 wire patient cable. Lead selection: DI, DII or DIII.
12 leads with 5 wire patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and C1, C2, C3, C4, C5 or C6.
50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
• Heart rate alarms, minimum and maximum: 20 to 300 1/min and off.
Lead off detection.
Pacemaker pulse detection.
• Pacemaker pulse rejection in counting the heart rate:
•Pulse rejected characteristic:
- Amplitude: from ±2 mV to ±700 mV
- pulse width: from 0.1 ms to 2.0 ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
• Detects and classifies the following arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy, Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
• Store up to 32 events and allows review and printing.
• Measurement of the S-T segment: both the isoelectric point and the ST point are user adjustable (J-point +60 ms or +80 ms, or any other value in ms, from 1 to 120 ms).
• Range: ±2.00 mV.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
• SpO2:
- Range: 35% to 100%
- Precision:
±2% from 80% to 100%.
±3% from 70% to 79%.
- Resolution: 1%.
- Alarm: 0% to 100% and off.
- Initial alarm: 85%.
• Pulse rate:
- Range: 25 to 250 1/min.
- Precision: ±2 1/min.
- Resolution: 1 1/min.
- Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

Accessories included:
Finger pulse oximeter sensor.

RESPIRATORY WAVEFORM
Impedanciometric method.
• Measurement selection: Transabdominal or Transtoraxic.
• Respiratory rate: 5 to 170 1/min.
Apnea Alarm.
• Respiratory rate alarm, minimum and maximum: 5 to 170 1/min and off.

NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method.
• Use: ADULT or NEONATE.
• Measurement mode: AUTOMATIC or MANUAL.
• Measure unit: mmHg.
• Resolution:
- Pressure: 1 mmHg.
- Pulse rate: 1 1/min.
• Transductor accuracy: ±3 mmHg.
• Ranges:
- PEDIATRIC/ADULT
Systolic pressure: 25 to 265 mmHg.
Diastolic pressure: 12 to 220 mmHg.
Mean pressure: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.
- NEONATE
Systolic pressure: 25 to 135 mmHg.
Diastolic pressure: 12 to 110 mmHg.
Mean pressure: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.
• Alarm limits of:
- Systolic pressure from 20 to 255 mmHg and off.
- Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
• Protections:Double protection from over-pressure.
- Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
- Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
- Protection for exceeding time of measurement.

Accessories included:
Cuff for Non Invasive Blood Pressure.
Hose for Non Invasive Blood Pressure.


INVASIVE BLOOD PRESSURE (IBP) (OPTIONAL)
1 or 2 channels of invasive blood pressure, according to customer's choice.
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
• Range: -30 to 300 mmHg.
• Mode selection for Pressure Ranges: Automatic or Manual.
• Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
• Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
• Measure unit: mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

TEMPERATURE (OPTIONAL)
2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
• Resolution: 0.1ºC.
• Accuracy: ±0.2ºC.
• Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

Accessories included:
Feas Electrónica temperature sensor - DB9M / G.
Derivation box for Temperature 1 and Temperature 2 parameters, DB9M connector (for two Temperature channels).

CARDIAC OUTPUT (OPTIONAL)
• Entry of patient parameters: Weight, height.
• Selection of:
- Injection volume: 3, 5 and 10 ml.
- Catheter Constant K or Computing Constant (CC)
- Measurement of the temperature in blood and injected.
• Calculation of:
- Body surface.
- CO: Volume in liters / min.
- SV: Stroke volume.
- CI: Cardiac index.
- SI: Systolic index.
Waveform graph for blood temperature as a function of time.
Manual or automatic start of the measurement when injecting.

Accessories included:
Catheter adapter cable for cardiac output - DB9M/G
Derivation box for parameters Temperature 1 and Cardiac Output with DB9.
Derivative box for parameters Temperature 1, Temperature 2 and Cardiac Output with DB9.

SIDESTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 170 1 / min.
• Accuracy:
- CO2, ± 2 mmHg for CO2 <5%.
- <10% of reading for CO2> 5%.
• Resolution:
- CO2, 1 mmHg.
- Respiratory Rate, 1 1 / min.
• Alarm:
- FiCO2, EtCO2, minimum and maximum, 0 to 100 mmHg and off.
- Minimum and maximum Respiratory Rate, 0 to 170 1 / min and off.
Calibration: 2 zero points (ambient air) and gain (5% or 10%).
Compensation for temperature and atmospheric pressure, O2 and N2O.

Accessories included:
Type "T" nozzle for Feás Electrónica lateral flow capnography.
2.4 m patient line for Feás Electrónica lateral flow capnography
Moisture filter for lateral flow capnography, Feas Electrónica

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1/min.
• Accuracy: CO2, ±3%ABS.
• Resolution: CO2, 1 mmHg.
- Respiratory Rate, 1 1/min.
• Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
• Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
• Measurement of N2 O: from 0% to 100%.
•Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate:
- 70 to 120 ml/min for neonatal patients.
- 120 to 250 ml/min for adult patients.

Accessories included:
"T" type nozzle for sidestream Capnography, Feas Electrónica.
2,4 m patient line for sidestream Capnography, Feas Electrónica
Water trap for use in lateral flow capnography and anesthetic gases.

MAINSTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1 / min.
• Accuracy: ± 2 mmHg between 0 and 40 mmHg and ± 5% of reading 41 and 70 mmHg.
• Resolution: 1 mmHg.
• Calibration: only zero (ambient air).
Compensation for temperature and atmospheric pressure, O2 and N2O.
Warm-up time <15s, to start measuring, within 2 minutes and obtain measurement values according to specifications.
• Waveform response time: less than 60 ms.

Accessories included:
Mainstream Capnography sensor, Feas Electrónica
Nozzle for mainstream Capnography sensor

FiO2 (OPTIONAL)
Fraction of inspired Oxygen: from 0% to 100%.
Polarographic cell measurement principle.
Alarms minimum and maximum: 0% to 100% and off.

Accessories included:
Derivative box for pressure 1, pressure 2 and / or FiO2 parameters with DB9M.
FiO2 Sensor, Feas Electrónica.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Spiral cable of Oxygen Sensor for FiO2, Feas Electrónica.

ANY OTHER OPTIONAL CHANNEL SPECIFIED CAN BE ADDED IN THE FUTURE.

TECHNICHAL SPECIFICATIONS
15” LCD-TFT Color Monitor
• Resolution: 1024x768.
Wide angle of visibility.
• Dimensions:
- Height: 345mm; Width: 335mm; Depth: 205mm.
• Weight: 6Kg.
• Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
• Power Consumption: 85VA.

CERTIFICATIONS
• Quality Standard (Certificates):
- ISO 13485.
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.

• Safety Standard (Certificates):
- UNE-EN60601-1.(Eq. IRAM 4220-1 and IEC 601-1).
- Electrical-shock protection: Class I – CF.
- UNE-EN60601-1-2 (Electromagnetic compatibility).
Authorized by A.N.M.A.T.: PM 1125-2.

ACCESSORIES
Included:3 or 5 leads patient cable.
Disposable electrodes.
SpO2 sensor.
SpO2 extension cable.
Cuff for NIBP.
Silicone hose for NIBP.
Temperature sensor Feas Electrónica - DB9M/G.
Derivation box for parameters of Temperature 1 and Temperature 2, DB9M connector.
FiO2 Sensor Feas Electrónica.
T Adapter for FiO2 sensor Feas Electrónica.
Spiral cable for FiO2 sensor Feas Electrónica.
Power cord.
User manual.
The image is illustrative.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Nellcor Doc-10 SpO2 Extension Cable
Nellcor Doc-10 SpO2 Extension Cable

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Neonatal oximeter sensor DB9M/G Feas Electrónica 3026
Neonatal oximeter sensor DB9M/G Feas Electronica 3026.

This sensor is used in oximetry monitoring systems to non-invasively determine Percent Oxygen Saturation (SpO2), pulse rate, and pulse plethysmographic waves.
Its use is indicated for patients of less than 3kg.

It has a length of 40 cm.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Neonatal water trap for sidestream capnography and anesthetic gases, Feas Electrónica
Disposable accessory, which prevents moisture from entering the equipment and connects the patient circuit line to the monitoring system. It can be reused as long as it is disinfected. It is implemented in adult and pediatric patients in a Feas Electrónica multiparameter monitor, under the supervision of trained health care staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (10-19cm), reusable, neonatal, 1-tube, Feas Electrónica
One-way cuff, with hose connector included, reusable, for non-invasive blood pressure measurement.

Size: 10 to 19 cm in circumference. Neonatal patient.
Suitable for human and animal patient.
Warranty: 3 months.

This bracelet is suitable for different brands of equipment and different equipment (multiparameter monitors, defibrillators, blood pressure monitors). What you have to take into account is the connevtor that is at the end of the hose, which must be the same to be able to connect to the equipment. If the connector is not the same, then you can save the connector from the cuff it will replace the connector on the cuff that came with your purchase.

Synonymous names: Armband/ Cuff/ Chambers for non-invasive pressure

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (12-30cm), reusable, small adult, 1-tube, Feas Electrónica
One-way reusable handle/ cuff for non-invasive blood pressure measurement.
Size: 23 to 33 cm in circumference.
With hose connector included
For adult patient

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (18-26cm), reusable, pediatric, 1-tube, Feas Electrónica
One-way resusable cuff for non-invasive blood pressure measurement.
Size: 18 to 26 cm arm circumference.
With hose connector included.
For a small pediatric patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (18-26cm), reusable, pediatric, 1-tube, Feas Electrónica
One-way resusable cuff for non-invasive blood pressure measurement.
Size: 18 to 26 cm arm circumference.
With hose connector included.
For a small pediatric patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (20,5-28cm), reusable, small adult, 1-tube, Feas Electrónica
One-way reusable cuff for non-invasive blood pressure measurement.
Size: 20,5 to 28 cm of arm circumference.
With hose connector included.
For small adult.
Suitable for human and animal patient.

This cuff is suitable for different brands of equipment and different equipment (patient monitors, defibrillators, blood pressure monitors). What must be taken into account is the connector at the end of the hose, which must be the same in order to connect to the equipment. If the connector is not the same, then you can save the connector on the cuff you will be replacing and use it to replace the connector on the cuff that will deliver with your purchase.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (27-36.5cm), reusable, adult, 1-tube, Feas Electrónica
One-way reusable handle/ cuff for non-invasive blood pressure measurement.
Size: 27.5 to 36.5 cm in circumference.
With hose connector included
For adult patient

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (33-47cm), reusable, large adult, 1 via, Feas Electrónica
One-way reusable Handle/Cuff for non-invasive blood pressurre measurement.
Size: 35,5 to 46 cm in circunference.
With hose connector included.
For adult patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (46-66cm), reusable, adult thigh, 1-tube, Feas Electrónica
Single tube reusable cuff for non-invasive blood pressure measurement.
Size: 46 to 66 cm arm circumference.
With hose connector included.
For adult patient and animal.
Suitable for human and animal patient.
Warranty: 3 months.
This bracelet is suitable for different brands of equipment and different equipment (multi-parameter patient monitors, defibrillators, blood pressure monitors). What must be taken into account is the connector at the end of the hose, which must be the same in order to connect to the equipment. If the connector is not the same, then you can save the connector from the bracelet that you will be replacing and use to replace the connector as the bracelet that was delivered with your purchase.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.