Neonatal water trap for sidestream capnography and anesthetic gases, Feas Electrónica
Disposable accessory, which prevents moisture from entering the equipment and connects the patient circuit line to the monitoring system. It can be reused as long as it is disinfected. It is implemented in adult and pediatric patients in a Feas Electrónica multiparameter monitor, under the supervision of trained health care staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Neonatal oximeter sensor DB9M/G Feas Electrónica 3026
Neonatal oximeter sensor DB9M/G Feas Electronica 3026.

This sensor is used in oximetry monitoring systems to non-invasively determine Percent Oxygen Saturation (SpO2), pulse rate, and pulse plethysmographic waves.
Its use is indicated for patients of less than 3kg.

It has a length of 40 cm.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Nellcor Doc-10 SpO2 Extension Cable
Nellcor Doc-10 SpO2 Extension Cable

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mainstream Capnography sensor, Feas Electrónica
The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injection temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Lingual oximeter sensor DB9F for veterinary use Feas Electrónica
Lingual sensor, reusable clip type, for the non-invasive measurement of blood oxygen saturation of veterinary patients. It allows to visualize the oxygen saturation (SpO2), the pulse frequency and the plestographic curve. Exclusive use in Feas Electronica multi-parameter monitor , under supervision of trained staff.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Intraesophageal/rectal temperature sensor DB9M/G Feas Electrónica
Feas Electrónica Intraesophageal/rectal temperature sensor DB9M/G

The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between Multipar and installation of Central Monitoring Station (DB9F-DB9F)
Cable to connect the multiparameter monitor to a wall connector of the installation of a Monitoring Central. They have a length of 1.5m and at both ends it has 1 female DB9 connector.
For use in multi-parameter monitors of Feas Electrónica brand, exclusively.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Filters kit of 13mm for sidestream capnography Feas Electrónica
Pair of filters to be used in sidestream capnography of Feas Electronica multiparametric monitors. The filters prevent the entry of particles to the components of the measurement system.
13 mm filter.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Feas Electrónica Sidestream CO2 Filter Kit
Composed by:
1 humidity filter for sidestream capnography, Feas Electrónica
and two 13mm filters for sidestream capnography, Feas Electrónica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
External battery power cord 12Vdc for vehicle
External battery power cord 12Vdc for vehicle

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable electrodes x 10 units
Disposable electrodes x 10 units
For patient cable.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Accessory to connect the oxygen inspired fraction (FiO2) sensor to the patient circuit. Exclusive use in Feas Electronica multiparametric monitor.

The T-Adapter is designed to be used in conjunction with the oxygen sensor (ref. 10101) in measurement systems of Inspired oxygen fraction (FiO2).

SPECS
T adapter, technical characteristics 22mm (inner diameter, outlet) x 15mm (inner diameter, T) x 22mm (outer diameter, inlet), HDPE material (High Density Polyethylene).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Temperature 1, Temperature 2 and Cardiac Output, DB9M connector
Parameter derivation box that allows the connection of two temperature sensors, both cutaneous and esophageal -rectal, and the catheter adapter cable for cardiac output measurement at the same time on the monitor. Exclusive use in Feas Electrónica multiparametric monitoring, under the supervision of personnel trained in health care.

The Derivation Boxes are designed to adapt the FEAS ELECTRÓNICA temperature sensors ref .: 1580, 1586, 1587 and 5871; and the catheter adapter cable ref .: 1581 to the Multipar LCD and PM9000 model monitors from Feas ELECTRÓNICA.

Protection against liquidos: IPX1
Length cable: 0,6 meters

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Temperature 1 and Cardiac Output, DB9M connector
Parameter derivation box that allows the connection of the esophageal-rectal temperature sensor and the catheter adapter cable for cardiac output measurement at the same time on the monitor. Exclusive use in Feas Electrónica multiparametric monitor, under the supervision of personnel trained in health care.

The Derivation Boxes are designed to adapt the FEAS ELECTRÓNICA temperature sensors ref .: 1580, 1586, 1587 and 5871; and the catheter adapter cable ref .: 1581 to the Multipar LCD and PM9000 model monitors from Feas ELECTRÓNICA.

Protection against liquidos: IPX1
Length cable: 0,6 meters

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Pressure 1, Pressure 2 and/or FiO2, DB9M connector
Parameter branch box that allows the connection of two invasive blood pressure transducer adapter cables and the interconnection cable with the fractional inspired oxygen (FiO2) measurement sensor at the same time on the monitor. Exclusive use in Feas Electrónica patient monitor, under supervision of trained health care personnel.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Pressure 1 and Pressure 2, DB9M connector
Caja derivadora de parámetros que permite la conexión de dos transductores de presión invasiva, al mismo tiempo, en el monitor multiparamétrico. Uso exclusivo en monitor multiparamétrico Feas Electrónica, bajo supervisión de personal capacitado en el cuidado de la salud.
Cutaneous temperature sensor for Adult/Pediatric/Neonate Feas Electrónica DB9M/G
Feas Electrónica adult cutaneous temperature sensor DB9M/G

The skin temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in Direct mode.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.80m.
Protection against ingress of liquids: IPX1

The temperature sensors must only work with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraphs and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Color video extension cable, 15m, injected

Video extension cable injected.

Length: 15 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Catheter adapter cable for cardiac output - DB9M/G
Catheter adapter cable for cardiac output - DB9M/G

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.