PS2 Mouse for Feas Electrónica equipment
Mouse for Feas Electrónica equipment

The mouse should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405, Polygraph for Hemodynamics studies model 1405 and Model 5032C Monitoring Center. The user is responsible for ensuring compatibility between the mouse and the computer.

Cable length: 1.5 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PS2 Keyboard for Model 1405 Electrophysiology Polygraph
The keyboard should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405.

The keyboard is used to operate the menu, which allows you to select sweep speed, ECG gains, pressure range, enter cardiac output measurement, freeze curves, perform caliper measurements, print curves, etc.

Use the keyboard to enter text and numbers. You can also activate some functions and start programs using key combinations and the numeric keypad. It also has hotkeys or quick access keys to optimize the user interface.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Oximeter sensor, reusable "Y" DB9M/G 3043 Feas Electrónica
Feas Electrónica reusable "Y" oximeter sensor DB9M/G 3043

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (6-13cm), reusable, small neonatal, 1-tube, Feas Electrónica
One-tube resusable cuff for non-invasive blood pressure measurement.

Size: 6 to 11 cm of arm circumference.
With hose connector included.
For pediatric or neonatal patient.

This cuff is suitable for different brands of equipment and different equipment (multi-parameter monitors, defibrillators, blood pressure monitors). What must be taken into account is the connector at the end of the hose, which must be the same in order to connect to the equipment. If the connector is not the same, then you can save the connector from the cuff that you will be replacing and use to replace the connector as the cuff that was delivered with your purchase.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (46-66cm), reusable, adult thigh, 1-tube, Feas Electrónica
Single tube reusable cuff for non-invasive blood pressure measurement.
Size: 46 to 66 cm arm circumference.
With hose connector included.
For adult patient and animal.
Suitable for human and animal patient.
Warranty: 3 months.
This bracelet is suitable for different brands of equipment and different equipment (multi-parameter patient monitors, defibrillators, blood pressure monitors). What must be taken into account is the connector at the end of the hose, which must be the same in order to connect to the equipment. If the connector is not the same, then you can save the connector from the bracelet that you will be replacing and use to replace the connector as the bracelet that was delivered with your purchase.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (27-36.5cm), reusable, adult, 1-tube, Feas Electrónica
One-way reusable handle/ cuff for non-invasive blood pressure measurement.
Size: 27.5 to 36.5 cm in circumference.
With hose connector included
For adult patient

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (18-26cm), reusable, pediatric, 1-tube, Feas Electrónica
One-way resusable cuff for non-invasive blood pressure measurement.
Size: 18 to 26 cm arm circumference.
With hose connector included.
For a small pediatric patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (18-26cm), reusable, pediatric, 1-tube, Feas Electrónica
One-way resusable cuff for non-invasive blood pressure measurement.
Size: 18 to 26 cm arm circumference.
With hose connector included.
For a small pediatric patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (12-30cm), reusable, small adult, 1-tube, Feas Electrónica
One-way reusable handle/ cuff for non-invasive blood pressure measurement.
Size: 23 to 33 cm in circumference.
With hose connector included
For adult patient

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff (10-19cm), reusable, neonatal, 1-tube, Feas Electrónica
One-way cuff, with hose connector included, reusable, for non-invasive blood pressure measurement.

Size: 10 to 19 cm in circumference. Neonatal patient.
Suitable for human and animal patient.
Warranty: 3 months.

This bracelet is suitable for different brands of equipment and different equipment (multiparameter monitors, defibrillators, blood pressure monitors). What you have to take into account is the connevtor that is at the end of the hose, which must be the same to be able to connect to the equipment. If the connector is not the same, then you can save the connector from the cuff it will replace the connector on the cuff that came with your purchase.

Synonymous names: Armband/ Cuff/ Chambers for non-invasive pressure

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mounting for side bar of hemodynamic bed for Polygraph preamplifier
Iron structure, which allows to maintain and move the preamplifier of hemodynamic studies through the procedure table. Use in Feas Electronica brand hemodynamic and electrophysiology polygraphs exclusively.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - Hemodynamic polygraph
RENT
Includes equipment rental. For different rental periods, please consult.

The Polygraph is a system for conducting electrophysiology and hemodynamic studies.

The system is intended to be used in the acquisition, processing and recording of physiological signals. This includes surface electrocardiography (ECG) and intracavitary (IECG, for Electrophysiology only), heart rate, pulse oximetry (optional), invasive and non-invasive pressure (optional), cardiac output and hemodynamic calculations, now the last two for Hemodynamics only.

It is made up of a central data processing unit (CPU), a preamplifier, a color monitor, a laser printer, a keyboard, a mouse and a recording pedal. For Electrophysiology (if applicable), the Polygraph catheter extension box is added.

FEATURES

Hemodynamics
- 2 simultaneous ECG leads on screen, selectable from 12 leads using 10 electrode wires.
- Up to 4 Invasive Pressures.
- Automatic calculation of the fractional flow reserve (FFR) in real time, without the need for an independent (external) FFR analyzer. The FFR allows determining the hemodynamic severity of vascular lesions.
- Numerical and graphic display of the FFR value.
- Study storage.
- Cardiac output by thermodilution. Calculation of BSA, CO, CI, SV, SI.
- Selection of Catheter Constant K.
- Selection of the injection volume.
- Entry of patient data (height and weight).
- Measurement of the temperature of the blood and the injected.
- Curve of blood temperature variation.
- Messages on screen.
- Recording of studies, stores curves and calculations.
- Measurement of body or injection temperature (during cardiac output).
- Allows you to freeze curves and measure times and amplitudes using calipers.
- Printing of frozen curves or recorded studies.
• HEMODYNAMIC CALCULATIONS:
- Aortic valve area.
- Pulmonary valve area.
- Calculation of pulmonary and systemic vascular resistance.

ELECTROPHYSIOLOGY (OPTIONAL)
- 18 simultaneous endocavitational channels.
- Calipers on Screen: allow you to measure time between events of interest.
- 12 simultaneous surface ECG leads.
- Up to 4 Invasive Pressures.
- Tabular presentation of P.N.I.
- Split Screen: allows you to have a frozen reference image in one window, and in the other view the monitoring in real time.
- Quick access to the curve configuration window, where you can make a continuous selection of position, amplitude, filter selection and customize colors and labels of curves.
- Synchronized triggering of the curve sweep (trigger).
- Recording Studies on a hard disk, to be transported to other computers or personal computers using a pen drive.
- One SpO2 channel.
- Study printing with selection of color and line width.
- Catheters connection box and Cardiac Stimulator
- Review of recorded studies, with the possibility of modifying the gain, position, color and limits (of amplitude) of the curves.
- Quick access keys.

Pulse Oximetry (OPTIONAL)
- Plethysmographic curve, visualization of the oxygen saturation percentage.
- Low perfusion and movement signal measurement.
• SpO2:
- Range from 0% to 100%.
- Adult Accuracy: 2% from 70% to 100%.
- Neonatal Accuracy: 3% from 70% to 100%.
- Accuracy in motion: 3% from 70% to 100%.
- Resolution: 1%.
• Pulse Rate:
- Range from 20 [1 / min] to 300 [1 / min].
- Adult Accuracy: ± 3 [1 / min].
- Neonatal precision: ± 3 [1 / min].
- Accuracy in movement: ± 5 [1 / min].
- Resolution: 1 [1 / min].

Non-Invasive Pressure (OPTIONAL)
- Start of measurement manually or automatically at programmable intervals from 2 minutes to 90 minutes.
- Selection of Adult or Neonatal patient.
- Visualization of the last 1440 measurements.
- Printing of measurements in tabular form.
- Includes cuff.

TECHNICAL SPECIFICATIONS
• Screen: LCD monitor 19 ”
- Dimensions: 19 ”(larger size; optional)
- Resolution: 1024 x 768 dots
•CPU:
- Industrial PC motherboard.
- 160 Gb hard disk.
- Output to connect an additional remote monitor.
• Printing machine:
- Laser Technology.
- Resolution 1200 dpi.
• Power supply:
- 110V ~ / 220V ~.
- Frequency 50/60 Hz.

• Quality Standard:
- ISO9001 (certified).
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F. (certificate).
- Disp. A.N.M.A.T. 2319/02 (certified).

• Safety Standard:
- UNE-EN60601-1 (Eq. IRAM 4220-1 and IEC 60601-1) Class I.
- Protection against electric shock: CF.
- Authorized by the A.N.M.A.T. PM 1125-23.

ACCESSORIES INCLUDED
- Preamplifier for Hemodynamic Studies.
- Interconnection cable from CPU to Preamplifier.
- Monitor, keyboard and mouse.
- Cable "Y" Minidin-M to 2 Minidin-F.
- Printing machine.
- Recording pedal with cable.
- CPU, monitor and printer power cables.
- Data cable to printer.
- Ground cable for interconnection between CPU and Preamplifier.
- Metal support for Preamplifier.
- Catheter extension box.
- Interconnection cable for catheter extension box.
- Mini equipment holder.
- TMM Bracket Mounting Clamp for TBC.
- Support plate for 4 transducers.
- Power strip with 5 shots.
- Disposable electrodes.
- 4 disposable pressure transducers.
- 4 interconnection cables from Preamplifier to disposable pressure transducers.
- Parameter derivation box for invasive pressure
- Injection temperature sensor.
- Patient cable with 3, 5 or 10 wires.
- Cardiac output catheter adapter cable.
- Oximeter sensor.
- Oximeter extension cable.
- Reus Adult Cuff.
- Silicone hose for PNI, 3m.
- Digital adapter for pressure guides (FFR).
- Volcano Pressure Guide Adapter Cable (FFR).
- Transport trolley (optional).
- User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - Electrophysiology Polygraph
RENT
Includes equipment rental. For different rental periods, please consult.

The Polygraph is a system for conducting electrophysiology and hemodynamic studies.

The system is intended to be used in the acquisition, processing and recording of physiological signals. This includes surface electrocardiography (ECG) and intracavitary (IECG, for Electrophysiology only), heart rate, pulse oximetry (optional), invasive and non-invasive pressure (optional), cardiac output and hemodynamic calculations, now the last two for Hemodynamics only.

It is made up of a central data processing unit (CPU), a preamplifier, a color monitor, a laser printer, a keyboard, a mouse and a recording pedal. For Electrophysiology (if applicable), the Polygraph catheter extension box is added.

FEATURES

Hemodynamics
- 2 simultaneous ECG leads on screen, selectable from 12 leads using 10 electrode wires.
- Up to 4 Invasive Pressures.
- Automatic calculation of the fractional flow reserve (FFR) in real time, without the need for an independent (external) FFR analyzer. The FFR allows determining the hemodynamic severity of vascular lesions.
- Numerical and graphic display of the FFR value.
- Study storage.
- Cardiac output by thermodilution. Calculation of BSA, CO, CI, SV, SI.
- Selection of Catheter Constant K.
- Selection of the injection volume.
- Entry of patient data (height and weight).
- Measurement of the temperature of the blood and the injected.
- Curve of blood temperature variation.
- Messages on screen.
- Recording of studies, stores curves and calculations.
- Measurement of body or injection temperature (during cardiac output).
- Allows you to freeze curves and measure times and amplitudes using calipers.
- Printing of frozen curves or recorded studies.
• HEMODYNAMIC CALCULATIONS:
- Aortic valve area.
- Pulmonary valve area.
- Calculation of pulmonary and systemic vascular resistance.

ELECTROPHYSIOLOGY (OPTIONAL)
- 18 simultaneous endocavitational channels.
- Calipers on Screen: allow you to measure time between events of interest.
- 12 simultaneous surface ECG leads.
- Up to 4 Invasive Pressures.
- Tabular presentation of P.N.I.
- Split Screen: allows you to have a frozen reference image in one window, and in the other view the monitoring in real time.
- Quick access to the curve configuration window, where you can make a continuous selection of position, amplitude, filter selection and customize colors and labels of curves.
- Synchronized triggering of the curve sweep (trigger).
- Recording Studies on a hard disk, to be transported to other computers or personal computers using a pen drive.
- One SpO2 channel.
- Study printing with selection of color and line width.
- Catheters connection box and Cardiac Stimulator
- Review of recorded studies, with the possibility of modifying the gain, position, color and limits (of amplitude) of the curves.
- Quick access keys.

Pulse Oximetry (OPTIONAL)
- Plethysmographic curve, visualization of the oxygen saturation percentage.
- Low perfusion and movement signal measurement.
• SpO2:
- Range from 0% to 100%.
- Adult Accuracy: 2% from 70% to 100%.
- Neonatal Accuracy: 3% from 70% to 100%.
- Accuracy in motion: 3% from 70% to 100%.
- Resolution: 1%.
• Pulse Rate:
- Range from 20 [1 / min] to 300 [1 / min].
- Adult Accuracy: ± 3 [1 / min].
- Neonatal precision: ± 3 [1 / min].
- Accuracy in movement: ± 5 [1 / min].
- Resolution: 1 [1 / min].

Non-Invasive Pressure (OPTIONAL)
- Start of measurement manually or automatically at programmable intervals from 2 minutes to 90 minutes.
- Selection of Adult or Neonatal patient.
- Visualization of the last 1440 measurements.
- Printing of measurements in tabular form.
- Includes cuff.

TECHNICAL SPECIFICATIONS
• Screen: LCD monitor 19 ”
- Dimensions: 19 ”(larger size; optional)
- Resolution: 1024 x 768 dots
•CPU:
- Industrial PC motherboard.
- 160 Gb hard disk.
- Output to connect an additional remote monitor.
• Printing machine:
- Laser Technology.
- Resolution 1200 dpi.
• Power supply:
- 110V ~ / 220V ~.
- Frequency 50/60 Hz.

• Quality Standard:
- ISO9001 (certified).
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F. (certificate).
- Disp. A.N.M.A.T. 2319/02 (certified).

• Safety Standard:
- UNE-EN60601-1 (Eq. IRAM 4220-1 and IEC 60601-1) Class I.
- Protection against electric shock: CF.
- Authorized by the A.N.M.A.T. PM 1125-23.

ACCESSORIES INCLUDED
- Preamplifier for Hemodynamic Studies.
- Interconnection cable from CPU to Preamplifier.
- Monitor, keyboard and mouse.
- Cable "Y" Minidin-M to 2 Minidin-F.
- Printing machine.
- Recording pedal with cable.
- CPU, monitor and printer power cables.
- Data cable to printer.
- Ground cable for interconnection between CPU and Preamplifier.
- Metal support for Preamplifier.
- Catheter extension box.
- Interconnection cable for catheter extension box.
- Mini equipment holder.
- TMM Bracket Mounting Clamp for TBC.
- Support plate for 4 transducers.
- Power strip with 5 shots.
- Disposable electrodes.
- 4 disposable pressure transducers.
- 4 interconnection cables from Preamplifier to disposable pressure transducers.
- Parameter derivation box for invasive pressure
- Injection temperature sensor.
- Patient cable with 3, 5 or 10 wires.
- Cardiac output catheter adapter cable.
- Oximeter sensor.
- Oximeter extension cable.
- Reus Adult Cuff.
- Silicone hose for PNI, 3m.
- Digital adapter for pressure guides (FFR).
- Volcano Pressure Guide Adapter Cable (FFR).
- Transport trolley (optional).
- User manual.

OTHER NAME FOR THE PRODUCT:
Polígrafo/ EPlab Electrophysiology Monitoring and Recording System/ Cathlab Hemodynamic Monitoring and Recording System/ Polígrafo de EP

FREQUENT QUESTION:
Can i add other parameters or optional modules to it in the future?
Yes, you can

IMPORTANT:
The equipment must return in good condition or with wear and tear according to the normal use of the equipment. For the realization of this service, the delivery of a check or promissory note for the value of the equipment will be requested as a guanrantee or ask for some other way of guaranteeing


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Intraesophageal/rectal temperature sensor DB9M/G Feas Electrónica
Feas Electrónica Intraesophageal/rectal temperature sensor DB9M/G

The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between signal retriever and Polygraph CPU REV. 0-0
Interconnection cable between signal retriever and Polygraph CPU

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between catheter extension box and Polygraph preamp
Interconnection cable between hemodynamic studies preamplifier and catheter extension box. They have variable lengths according to the installation of the equipment, use in hemodynamic polygraphs and electrophysiology of Feas Electronica brand exclusively.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between catheter extender and polygraph preamplifier (2,5 m)
Interconnection cable between catheter extender and polygraph preamplifier

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamic cath lab / SpO2 / NIBP

Interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamic System with Optionals: / SpO2 / PNI for digital system
Connects the Polygraph Main Unit with the signal preamplifier box, which contains the connectors for the patient cables and sensors.
It is a cable, by default, 5m long, but you can request longer lengths by contacting our Customer Service for advice.
For exclusive use in Electrophysiology and Hemodynamic systems Mod. 1405, Feas Electrónica brand, for digital communication

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Installation and start up of Polygraph
PROPOSAL 1
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table in the hemodynamic room or on the track of the same.
Cost:
- Chageable: if the technician must go to the institution to perform the installation
- Free of charge: if telephone or videoconference support is provided from the factory.

PROPOSAL 2
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table inside the Hemodynamics room or on the track of the same.
• repeater monitor hung on existing monitor stand.
Cost:
- Chargeable: if the technician must go to the institution to perform the installation
- Free of charge: if the installation is attended by telephone or videoconference.

PROPOSAL 3
Arrangement of the elements:
• CPU, printer and monitor in bunker,
• wireless mouse and keyboard on the table in the catheterization room or in the bunker,
• Preamplifier under the table inside the hemodynamic room or on the track of the same,
• repeater monitor hung on existing monitor support with connection to bunker.
Cost: with charge, the technician will travel to the institution to carry out the installation.
Electrophysiology and hemodynamic polygraph system mod. 1405 Feas Electrónica
The Polygraph is a system for conducting electrophysiology and hemodynamic studies.

The system is intended to be used in the acquisition, processing and recording of physiological signals. This includes surface electrocardiography (ECG) and intracavitary (IECG, for Electrophysiology only), heart rate, pulse oximetry (optional), invasive and non-invasive pressure (optional), cardiac output and hemodynamic calculations, now the last two for Hemodynamics only.

It is made up of a central data processing unit (CPU), a preamplifier, a color monitor, a laser printer, a keyboard, a mouse and a recording pedal. For Electrophysiology (if applicable), the Polygraph catheter extension box is added.

FEATURES

Hemodynamics
- 2 simultaneous ECG leads on screen, selectable from 12 leads using 10 electrode wires.
- Up to 4 Invasive Pressures.
- Automatic calculation of the fractional flow reserve (FFR) in real time, without the need for an independent (external) FFR analyzer. The FFR allows determining the hemodynamic severity of vascular lesions.
- Numerical and graphic display of the FFR value.
- Study storage.
- Cardiac output by thermodilution. Calculation of BSA, CO, CI, SV, SI.
- Selection of Catheter Constant K.
- Selection of the injection volume.
- Entry of patient data (height and weight).
- Measurement of the temperature of the blood and the injected.
- Curve of blood temperature variation.
- Messages on screen.
- Recording of studies, stores curves and calculations.
- Measurement of body or injection temperature (during cardiac output).
- Allows you to freeze curves and measure times and amplitudes using calipers.
- Printing of frozen curves or recorded studies.
• HEMODYNAMIC CALCULATIONS:
- Aortic valve area.
- Pulmonary valve area.
- Calculation of pulmonary and systemic vascular resistance.

ELECTROPHYSIOLOGY (OPTIONAL)
- 18 simultaneous endocavitational channels.
- Calipers on Screen: allow you to measure time between events of interest.
- 12 simultaneous surface ECG leads.
- Up to 4 Invasive Pressures.
- Tabular presentation of P.N.I.
- Split Screen: allows you to have a frozen reference image in one window, and in the other view the monitoring in real time.
- Quick access to the curve configuration window, where you can make a continuous selection of position, amplitude, filter selection and customize colors and labels of curves.
- Synchronized triggering of the curve sweep (trigger).
- Recording Studies on a hard disk, to be transported to other computers or personal computers using a pen drive.
- One SpO2 channel.
- Study printing with selection of color and line width.
- Catheters connection box and Cardiac Stimulator
- Review of recorded studies, with the possibility of modifying the gain, position, color and limits (of amplitude) of the curves.
- Quick access keys.

Pulse Oximetry (OPTIONAL)
- Plethysmographic curve, visualization of the oxygen saturation percentage.
- Low perfusion and movement signal measurement.
• SpO2:
- Range from 0% to 100%.
- Adult Accuracy: 2% from 70% to 100%.
- Neonatal Accuracy: 3% from 70% to 100%.
- Accuracy in motion: 3% from 70% to 100%.
- Resolution: 1%.
• Pulse Rate:
- Range from 20 [1 / min] to 300 [1 / min].
- Adult Accuracy: ± 3 [1 / min].
- Neonatal precision: ± 3 [1 / min].
- Accuracy in movement: ± 5 [1 / min].
- Resolution: 1 [1 / min].

Non-Invasive Pressure (OPTIONAL)
- Start of measurement manually or automatically at programmable intervals from 2 minutes to 90 minutes.
- Selection of Adult or Neonatal patient.
- Visualization of the last 1440 measurements.
- Printing of measurements in tabular form.
- Includes cuff.

TECHNICAL SPECIFICATIONS
• Screen: LCD monitor 19 ”
- Dimensions: 19 ”(larger size; optional)
- Resolution: 1024 x 768 dots
•CPU:
- Industrial PC motherboard.
- 160 Gb hard disk.
- Output to connect an additional remote monitor.
• Printing machine:
- Laser Technology.
- Resolution 1200 dpi.
• Power supply:
- 110V ~ / 220V ~.
- Frequency 50/60 Hz.

• Quality Standard:
- ISO9001 (certified).
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F. (certificate).
- Disp. A.N.M.A.T. 2319/02 (certified).

• Safety Standard:
- UNE-EN60601-1 (Eq. IRAM 4220-1 and IEC 60601-1) Class I.
- Protection against electric shock: CF.
- Authorized by the A.N.M.A.T. PM 1125-23.

ACCESSORIES INCLUDED
- Preamplifier for Hemodynamic Studies.
- Interconnection cable from CPU to Preamplifier.
- Monitor, keyboard and mouse.
- Cable "Y" Minidin-M to 2 Minidin-F.
- Printing machine.
- Recording pedal with cable.
- CPU, monitor and printer power cables.
- Data cable to printer.
- Ground cable for interconnection between CPU and Preamplifier.
- Metal support for Preamplifier.
- Catheter extension box.
- Interconnection cable for catheter extension box.
- Mini equipment holder.
- TMM Bracket Mounting Clamp for TBC.
- Support plate for 4 transducers.
- Power strip with 5 shots.
- Disposable electrodes.
- 4 disposable pressure transducers.
- 4 interconnection cables from Preamplifier to disposable pressure transducers.
- Parameter derivation box for invasive pressure
- Injection temperature sensor.
- Patient cable with 3, 5 or 10 wires.
- Cardiac output catheter adapter cable.
- Oximeter sensor.
- Oximeter extension cable.
- Reus Adult Cuff.
- Silicone hose for PNI, 3m.
- Digital adapter for pressure guides (FFR).
- Volcano Pressure Guide Adapter Cable (FFR).
- Transport trolley (optional).
- User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.