Interconnection cable between CPU and preamplifier of Polygraph of Electrophysiology and Hemodynamic/ SpO2 / PNI
Interconnection cable between CPU and preamplifier of Polygraph of Electrophysiology and Hemodynamics

It allows you to connect the Polygraph Main Unit with the signal preamplifier box, which contains the connectors for the patient cables and sensors.
It is a cable, by default, 5m long, but you can request longer lengths by contacting our Customer Service for advice.

Available lengths: 5, 8, 9 and 10 meters.
For exclusive use in Electrophysiology and Hemodynamic polygraphs Mod. 1405, Feas Electrónica for digital communication

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
AC inlet EMI/RFI filter 04SS3A-2SR-Q fused 4A-250VAC RoHS H&L corp-PN: 530040302014100
EMI/RFI filter 04SS3A-2SR-Q, 4A 250VAC-PN: 530040302014100

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adapater for pressure guides (FFR) for polygraph Feas Electrónica
The use of RADI or Volcano pressure guides is suggested. If you have another brand of guide, consult our after-sales service.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 2.5 meters.
Protection against liquids: IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Electrophisiology module for polygraph
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

ELECTROPHYSIOLOGY
- 18 simultaneous channels of intracavitary ECG.
- Calipers on screen for measurement of time between events.
- 12 leads simultaneous surface electrocardiogram
- Up to four channels of invasive blood pressure (2+2 optionals)
- Tabular displaying of Non Invasive Blood Pressure measures.
-Split screen mode
- Allows using one half of the screen for frozen images as a reference, while the other half of the screen continues monitoring in real time.
- Shortcut for curves Configuration allows to:
- Continuous waveform positioning, gain and Clipping.
- Customized label and color for waveforms.
- Triggered sweep display mode
- Storing the patient case studies into a hard disk for transporting to other equipment or to personal computers using a pen drive.
- A Chanel of Spo2.
- Print out of the patient case studies with selection of color and width trace.
- Conection box for Catheters and Cardiac stimulator.
- Recall of recorded diagnosting data in order to perform its revision, with the possibility of modifying gain, position, color and waveform limits (amplitude).
- Shortcut keys.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Non invasive blood pressure module for polygraph
The following module allows to perform Non-Invasive pressure and obtain the measurement of systolic, mean and diastolic pressure.

NON-INVASIVE BLOOD PRESSURE

Display on the screen of the Systolic, Mean and Diastolic Pressure and Pulse Frequency values.
Type of Patient: ADULT OR NEONATAL.
Start mode of the measurement: AUTOMATIC or MANUAL.
Measurement period in automatic mode: 2 min, 3 min, 4 min, 5 min, 10 min, 15 min, 30 min, 60 min and 90min.
Measurement method: Oscilometric.

Resolution of the parameters
Pressure: 1mmHg.
Frecuency to pulse 1 [1 / min].
Transducer accuracy: ± 3mmHg.
Maximum average error: ± 3 mmHg.
Maximum standard deviation: 8mmHg.
These specifications are given for a temperature range between 10ºC and 40ºC and a humidity range between 15% and 85% RH no condensing. The altitude does not affect the measurement because it is relative to the local atmospheric pressure.

Range:
ADULT
- Systolic: 25 mmHg to 265mmHg.
- Diastolic: 12 mmHg to 220mmHg.
- Average: 18 mmHg to 245mmHg.
- Pulse freq: 40 [1/min] to 240 [1/min]
NEONATAL
- Systolic: 25 mmHg to 135mmHg.
- Diastolic: 12 mmHg to 110mmHg.
- Average: 18 mmHg to 120mmHg.
- Pulse freq:40 [1/min] to 240 [1/min]

Maximum inflation pressure:
- Adult: 290 mmHg ± 3mmHg
- Neonatal: 145 mmHg ± 3mmHg
- Initial inflation pressure: Adult: 150 mmHg.
- Neonatal: 70 mmHg.

Display of the last 1440 measurements taken.
Printing: tabular presentation of the measurements.
Deletion of the table of measurements taken.

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate SpO2 module for Polygraph Mod. 1405
The next module will allow you to monitor the plethysmographic curve, SpO2 values ​​and Pulse Rate.

OXIMETRY (SpO2)
- SpO2 Range: 0 % to 100%.
- Accuracy:
Adult, 2% from 70% to 100%
Neonatal: 3% from 70% to 100%,
In movement: 3% from 70% to 100%.
- Resolution: 1%.
- Percent oxygen saturation alarm:
Upper limit: 1 -> 100 and lower limit: 0 -> 99.
- Measurement of pulse frequency and alarms from 30 to 250 (1 / min) ± 3 (1 / min) and ± 5 (1 / min) in motion.
- Resolution: 1 (1 / min).

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of adictional invasive pressure module (third and fourth channel) for polygraph
The Polygraph for Hemodynamics and Electrophysiology studies allows the monitoring of up to four isolated invasive pressure channels. By adding this module you will get the third and fourth channel.

If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
American standard Power cord 110V plug NEMA 5-15p 3 pin Feas Electrónica
Feas Electronica equipment power cable with American plug NEMA 5-15p 3 pin

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Analog interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamics Polygraph / SpO2 / PNI
Analog interconnection cable between CPU and Electrophysiology and Hemodynamics Polygraph preamplifier / SpO2 / PNI
The length of the cable is adaptable to the installation, with lengths of 5, 8, 9 and 10 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Catheter adapter cable for cardiac output - DB9M/G
Catheter adapter cable for cardiac output - DB9M/G

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Cutaneous temperature sensor for Adult/Pediatric/Neonate Feas Electrónica DB9M/G
Feas Electrónica adult cutaneous temperature sensor DB9M/G

The skin temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in Direct mode.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.80m.
Protection against ingress of liquids: IPX1

The temperature sensors must only work with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraphs and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable electrodes x 10 units
Disposable electrodes x 10 units
For patient cable.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Earth wire for interconnection between CPU and cath lab preamplifier
Ground wire between CPU and Electrophysiology and Hemodynamics Polygraph preamplifier, DIGITAL

The length of the cable is adaptable to the installation, with lengths of 5, 8, 9, 10, 11, 12, 13, 14, and 15mts.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Electrophysiology and hemodynamic polygraph system mod. 1405 Feas Electrónica
The Polygraph is a system for conducting electrophysiology and hemodynamic studies.

The system is intended to be used in the acquisition, processing and recording of physiological signals. This includes surface electrocardiography (ECG) and intracavitary (IECG, for Electrophysiology only), heart rate, pulse oximetry (optional), invasive and non-invasive pressure (optional), cardiac output and hemodynamic calculations, now the last two for Hemodynamics only.

It is made up of a central data processing unit (CPU), a preamplifier, a color monitor, a laser printer, a keyboard, a mouse and a recording pedal. For Electrophysiology (if applicable), the Polygraph catheter extension box is added.

FEATURES

Hemodynamics
- 2 simultaneous ECG leads on screen, selectable from 12 leads using 10 electrode wires.
- Up to 4 Invasive Pressures.
- Automatic calculation of the fractional flow reserve (FFR) in real time, without the need for an independent (external) FFR analyzer. The FFR allows determining the hemodynamic severity of vascular lesions.
- Numerical and graphic display of the FFR value.
- Study storage.
- Cardiac output by thermodilution. Calculation of BSA, CO, CI, SV, SI.
- Selection of Catheter Constant K.
- Selection of the injection volume.
- Entry of patient data (height and weight).
- Measurement of the temperature of the blood and the injected.
- Curve of blood temperature variation.
- Messages on screen.
- Recording of studies, stores curves and calculations.
- Measurement of body or injection temperature (during cardiac output).
- Allows you to freeze curves and measure times and amplitudes using calipers.
- Printing of frozen curves or recorded studies.
• HEMODYNAMIC CALCULATIONS:
- Aortic valve area.
- Pulmonary valve area.
- Calculation of pulmonary and systemic vascular resistance.

ELECTROPHYSIOLOGY (OPTIONAL)
- 18 simultaneous endocavitational channels.
- Calipers on Screen: allow you to measure time between events of interest.
- 12 simultaneous surface ECG leads.
- Up to 4 Invasive Pressures.
- Tabular presentation of P.N.I.
- Split Screen: allows you to have a frozen reference image in one window, and in the other view the monitoring in real time.
- Quick access to the curve configuration window, where you can make a continuous selection of position, amplitude, filter selection and customize colors and labels of curves.
- Synchronized triggering of the curve sweep (trigger).
- Recording Studies on a hard disk, to be transported to other computers or personal computers using a pen drive.
- One SpO2 channel.
- Study printing with selection of color and line width.
- Catheters connection box and Cardiac Stimulator
- Review of recorded studies, with the possibility of modifying the gain, position, color and limits (of amplitude) of the curves.
- Quick access keys.

Pulse Oximetry (OPTIONAL)
- Plethysmographic curve, visualization of the oxygen saturation percentage.
- Low perfusion and movement signal measurement.
• SpO2:
- Range from 0% to 100%.
- Adult Accuracy: 2% from 70% to 100%.
- Neonatal Accuracy: 3% from 70% to 100%.
- Accuracy in motion: 3% from 70% to 100%.
- Resolution: 1%.
• Pulse Rate:
- Range from 20 [1 / min] to 300 [1 / min].
- Adult Accuracy: ± 3 [1 / min].
- Neonatal precision: ± 3 [1 / min].
- Accuracy in movement: ± 5 [1 / min].
- Resolution: 1 [1 / min].

Non-Invasive Pressure (OPTIONAL)
- Start of measurement manually or automatically at programmable intervals from 2 minutes to 90 minutes.
- Selection of Adult or Neonatal patient.
- Visualization of the last 1440 measurements.
- Printing of measurements in tabular form.
- Includes cuff.

TECHNICAL SPECIFICATIONS
• Screen: LCD monitor 19 ”
- Dimensions: 19 ”(larger size; optional)
- Resolution: 1024 x 768 dots
•CPU:
- Industrial PC motherboard.
- 160 Gb hard disk.
- Output to connect an additional remote monitor.
• Printing machine:
- Laser Technology.
- Resolution 1200 dpi.
• Power supply:
- 110V ~ / 220V ~.
- Frequency 50/60 Hz.

• Quality Standard:
- ISO9001 (certified).
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F. (certificate).
- Disp. A.N.M.A.T. 2319/02 (certified).

• Safety Standard:
- UNE-EN60601-1 (Eq. IRAM 4220-1 and IEC 60601-1) Class I.
- Protection against electric shock: CF.
- Authorized by the A.N.M.A.T. PM 1125-23.

ACCESSORIES INCLUDED
- Preamplifier for Hemodynamic Studies.
- Interconnection cable from CPU to Preamplifier.
- Monitor, keyboard and mouse.
- Cable "Y" Minidin-M to 2 Minidin-F.
- Printing machine.
- Recording pedal with cable.
- CPU, monitor and printer power cables.
- Data cable to printer.
- Ground cable for interconnection between CPU and Preamplifier.
- Metal support for Preamplifier.
- Catheter extension box.
- Interconnection cable for catheter extension box.
- Mini equipment holder.
- TMM Bracket Mounting Clamp for TBC.
- Support plate for 4 transducers.
- Power strip with 5 shots.
- Disposable electrodes.
- 4 disposable pressure transducers.
- 4 interconnection cables from Preamplifier to disposable pressure transducers.
- Parameter derivation box for invasive pressure
- Injection temperature sensor.
- Patient cable with 3, 5 or 10 wires.
- Cardiac output catheter adapter cable.
- Oximeter sensor.
- Oximeter extension cable.
- Reus Adult Cuff.
- Silicone hose for PNI, 3m.
- Digital adapter for pressure guides (FFR).
- Volcano Pressure Guide Adapter Cable (FFR).
- Transport trolley (optional).
- User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Installation and start up of Polygraph
PROPOSAL 1
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table in the hemodynamic room or on the track of the same.
Cost:
- Chageable: if the technician must go to the institution to perform the installation
- Free of charge: if telephone or videoconference support is provided from the factory.

PROPOSAL 2
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table inside the Hemodynamics room or on the track of the same.
• repeater monitor hung on existing monitor stand.
Cost:
- Chargeable: if the technician must go to the institution to perform the installation
- Free of charge: if the installation is attended by telephone or videoconference.

PROPOSAL 3
Arrangement of the elements:
• CPU, printer and monitor in bunker,
• wireless mouse and keyboard on the table in the catheterization room or in the bunker,
• Preamplifier under the table inside the hemodynamic room or on the track of the same,
• repeater monitor hung on existing monitor support with connection to bunker.
Cost: with charge, the technician will travel to the institution to carry out the installation.
Interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamic cath lab / SpO2 / NIBP

Interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamic System with Optionals: / SpO2 / PNI for digital system
Connects the Polygraph Main Unit with the signal preamplifier box, which contains the connectors for the patient cables and sensors.
It is a cable, by default, 5m long, but you can request longer lengths by contacting our Customer Service for advice.
For exclusive use in Electrophysiology and Hemodynamic systems Mod. 1405, Feas Electrónica brand, for digital communication

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Interconnection cable between catheter extender and polygraph preamplifier (2,5 m)
Interconnection cable between catheter extender and polygraph preamplifier

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.