Aggregate Electrophisiology module for polygraph
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

ELECTROPHYSIOLOGY
- 18 simultaneous channels of intracavitary ECG.
- Calipers on screen for measurement of time between events.
- 12 leads simultaneous surface electrocardiogram
- Up to four channels of invasive blood pressure (2+2 optionals)
- Tabular displaying of Non Invasive Blood Pressure measures.
-Split screen mode
- Allows using one half of the screen for frozen images as a reference, while the other half of the screen continues monitoring in real time.
- Shortcut for curves Configuration allows to:
- Continuous waveform positioning, gain and Clipping.
- Customized label and color for waveforms.
- Triggered sweep display mode
- Storing the patient case studies into a hard disk for transporting to other equipment or to personal computers using a pen drive.
- A Chanel of Spo2.
- Print out of the patient case studies with selection of color and width trace.
- Conection box for Catheters and Cardiac stimulator.
- Recall of recorded diagnosting data in order to perform its revision, with the possibility of modifying gain, position, color and waveform limits (amplitude).
- Shortcut keys.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate SpO2 module for Polygraph Mod. 1405
The next module will allow you to monitor the plethysmographic curve, SpO2 values ​​and Pulse Rate.

OXIMETRY (SpO2)
- SpO2 Range: 0 % to 100%.
- Accuracy:
Adult, 2% from 70% to 100%
Neonatal: 3% from 70% to 100%,
In movement: 3% from 70% to 100%.
- Resolution: 1%.
- Percent oxygen saturation alarm:
Upper limit: 1 -> 100 and lower limit: 0 -> 99.
- Measurement of pulse frequency and alarms from 30 to 250 (1 / min) ± 3 (1 / min) and ± 5 (1 / min) in motion.
- Resolution: 1 (1 / min).

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Non invasive blood pressure module for polygraph
The following module allows to perform Non-Invasive pressure and obtain the measurement of systolic, mean and diastolic pressure.

NON-INVASIVE BLOOD PRESSURE

Display on the screen of the Systolic, Mean and Diastolic Pressure and Pulse Frequency values.
Type of Patient: ADULT OR NEONATAL.
Start mode of the measurement: AUTOMATIC or MANUAL.
Measurement period in automatic mode: 2 min, 3 min, 4 min, 5 min, 10 min, 15 min, 30 min, 60 min and 90min.
Measurement method: Oscilometric.

Resolution of the parameters
Pressure: 1mmHg.
Frecuency to pulse 1 [1 / min].
Transducer accuracy: ± 3mmHg.
Maximum average error: ± 3 mmHg.
Maximum standard deviation: 8mmHg.
These specifications are given for a temperature range between 10ºC and 40ºC and a humidity range between 15% and 85% RH no condensing. The altitude does not affect the measurement because it is relative to the local atmospheric pressure.

Range:
ADULT
- Systolic: 25 mmHg to 265mmHg.
- Diastolic: 12 mmHg to 220mmHg.
- Average: 18 mmHg to 245mmHg.
- Pulse freq: 40 [1/min] to 240 [1/min]
NEONATAL
- Systolic: 25 mmHg to 135mmHg.
- Diastolic: 12 mmHg to 110mmHg.
- Average: 18 mmHg to 120mmHg.
- Pulse freq:40 [1/min] to 240 [1/min]

Maximum inflation pressure:
- Adult: 290 mmHg ± 3mmHg
- Neonatal: 145 mmHg ± 3mmHg
- Initial inflation pressure: Adult: 150 mmHg.
- Neonatal: 70 mmHg.

Display of the last 1440 measurements taken.
Printing: tabular presentation of the measurements.
Deletion of the table of measurements taken.

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of adictional invasive pressure module (third and fourth channel) for polygraph
The Polygraph for Hemodynamics and Electrophysiology studies allows the monitoring of up to four isolated invasive pressure channels. By adding this module you will get the third and fourth channel.

If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.