External paddles for 3850B defibrillator
Part of External Paddles for 3850B Desfibrillator Feas Electronica

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pair of Electrodes for pacemaker, Gray color, 95mm diameter
Pair of gray electrodes, 95 mm in diameter, for pacemakers.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Electrode pads for AED Heart+ResQ NT-381.C Nanoomtech Feas Electrónica
Electrode pads
• Shelf life: 2 (two) years.
• Single use.
• Cable length: 2.1 m (± 1%).
• Applicable ages: to people older than 12 months.
• Sealed: hermetic.
• Size: 125mm x 95mm.
• Location of pads:
Adult: anterior-lateral.
Pediatric: anterior-posterior (see positioning details on the container label).


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermal paper for ECG 50mm x 25m
Brand Sensitherm
Direct Inscription Electrocardiograph Paper. Thermochemical Type.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
15 inch AUO led panel A150XN01 V.2 With LVDS cable
15 inch TFT-LCD LED panel with backlight, AUO A150XN01 V.2 with LVDS cable

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pump Infusion Clamp model SN-1500H
Infusion pump hose occluder for Mod. SN-1500H

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PS2 Mouse for Feas Electrónica equipment
Mouse for Feas Electrónica equipment

The mouse should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405, Polygraph for Hemodynamics studies model 1405 and Model 5032C Monitoring Center. The user is responsible for ensuring compatibility between the mouse and the computer.

Cable length: 1.5 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mounting for side bar of hemodynamic bed for Polygraph preamplifier
Iron structure, which allows to maintain and move the preamplifier of hemodynamic studies through the procedure table. Use in Feas Electronica brand hemodynamic and electrophysiology polygraphs exclusively.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, Modular, Comen, Model C90 + C30
COMEN C90 is a device designed to meet the most advanced needs for room monitoring, intermediate care, intensive care, among others. Created to be used in adult, pediatric and neonatal patients. Able to improve in its benefits, according to the needs of the user and the complexity of its clinical unit. This is due to the use of modules for the different extended functions that are required by clinicians.
Features
• It has a C30 multiparameter module, removable and usable as transfer equipment.
• Large high resolution touch screen
• For highly complex monitoring

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used on animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 12,1", Comen, with Batery Li ion include, Touch screen, light, model C80
MULTIPARAMETER MONITOR C80

C80 provides the clinician with advanced functionality and monitoring options to meet the demands of a wide range of care in any hospital setting.
It has a color screen with TFT technology of 10.4" inclined to facilitate observation.
Easy menu use via rotary knob and touch screen.
In addition, it has reserved expansion ports such as for SD card, USB port and network.

Adult, Pediatric, Neonatal Use

ELECTROCARDIOGRAM(ECG)
Heart rate:
•Adult: 15-300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Accuracy: ±1% o ±1 [1/min], whichever is greater.
Resolution: ±1 [1/min]
Gain selection: 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 40mm/mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12 lead ECG input mode.
Selection of leads:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF y V
3. DI, DII, DIII, aVR, aVL, aVF y V1 a V6
Frequency response:
•Monitoring mode: 0.5-40Hz.
•Deagnostic mode: 0.05-130Hz.
•Surgery modality: 1-20Hz.
•ST Mode: 0.05-40hZ.
Heart rate alarms:
•Adult: 15 - 300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ±2mV~±700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia type: PVC, Asystoloe, VTac, Tachycardia, Ventricular tachycardia, Supraventricular tachycardia, VR, Bigeminia, Trigeminia, R on T, Bradycardia, Ventricular bradycardia, missed beats, Atrial fibrillation, Ventricular fibrillation, Non-captured pacemaker (NCP), Non-captured pacemaker (PNP).
ST segment analysis:
Range: -2mV to +2mV
Accuracy: Measurement tolerance within (-0.8 mV)-(+0.8 mV) is ±0.02 mV or ±10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curse, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
Comen SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, the tolerance is ±2% (without movement).
Neonatal Accuracy: within 70% -100%, the tolerance is ±3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE RATE
Comen SpO2:
Range: 20 - 254 [1/min]
Resolution: 1[1/min]
Accuracy: ±2 [1/min]
Alarm: 20 a 350 [1/min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Within 7 [1/min] – 150 [1/min], the measurement error is ±2 rpm or ±2%, whichever is greater.
The tolerance is not defined by other ranges.
Alarm Limit Specification:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscillometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Measurement unit: mmHg
Nominal Monitoring Range:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Alarm Limit Specifications:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric Range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Precision:
The mean error should be less than 5mmHg
The standard deviation should be less than 8mmHg.
Manual or automatic start of measurement at programmable intervals of 1/ 2/ 2.5/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 180/ 240/ 480/ 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
•Adult: When the cuff pressure exceeds 297 mmHg ±3mmHg, the control valve will relieve the pressure.
•Child: When the cuff pressure exceeds 240 mmHg ±3 mmHg, the control valve will relieve the pressure.
•Neonate: When the cuff pressure exceeds 147 mmHg ±3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement Method: direct.
A temperature channel.
Temperature Ranges
Range: 0 - 50° C
Accuracy: ±0.1°C (Exclusive of probe tolerance)
Resolution: 0.1°C
Maximum and minimum temperature alarms:
Range: 0 - 50° C


TECHNICAL SPECIFICATIONS

12.1" color touch screen with TFT technology Resolution: 800 X 600
Inclined screen to facilitate observation.
Dimensions: 344 mm x 291 mm x 165 mm
Weight 3.9 Kg. with battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 – 240 Vac, 50/60 Hz.
C80: Standard: Li-Ion 11.8V/2200mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60VA
Reserved expansion ports such as SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 10,4", Comen, With Batery Li ion include, Touch screen, Light, model C50
C50 PATIENT MONITOR

C50 provides the physician with advanced functionalities and monitoring options in order to meet the demands of a wide range of care in any hospital environment.
It has a 10.4 "" color screen with TFT technology included to facilitate observation.
Easy use of the menu via rotary knob and touch screen.
In addition, it has reserved expansion ports for SD card, USB port and network.

Use Adult, Pediatric, Neonatal

ELECTROCARDIOGRAM (ECG)
Heart rate:
• Adult: 15-300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Accuracy: ± 1% or ± 1 [1 / min], whichever is greater.
Resolution: ± 1 [1 / min]
Gain selection: 1.25mm / mV, 2.5mm / mV, 5.0mm / mV, 10mm / mV, 40mm / mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12-lead ECG input mode.
Lead selection:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF and V
3. DI, DII, DIII, aVR, aVL, aVF and V1 to V6
Frequency response:
• Monitoring mode: 0.5-40Hz.
• Diagnostic mode: 0.05-130Hz.
• Surgery mode: 1-20Hz.
• ST mode: 0.05-40hZ.
Heart rate alarms:
• Adult: 15 - 300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ± 2mV ~ ± 700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia Type: PVC, Asystole, VTac, Tachycardia, Ventricular Tachycardia, Supraventricular Tachycardia, VR, Bigemine, Trigemine, R over T, Bradycardia, Ventricular Bradycardia, Missed Beats, Atrial Fibrillation, Ventricular Fibrillation, Pacemaker Not Captured (PNC) Pacemaker does not dial (PNP).
ST segment analysis:
Range: -2mV to + 2mV
Accuracy: Measurement tolerance within (-0.8 mV) - (+ 0.8 mV) is ± 0.02 mV or ± 10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curve, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
COMEN SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, tolerance is ± 2% (no movement).
Neonatal Accuracy: Within 70% -100%, tolerance is ± 3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE FREQUENCY
COMEN SpO2:
Range: 20 - 254 [1 / min]
Resolution: 1 [1 / min]
Accuracy: ± 2 [1 / min]
Alarm: 20 to 350 [1 / min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child/neonate: 0 to 150 [1 / min]
Within 7 [1 / min] - 150 [1 / min], the measurement error is ± 2 rpm or ± 2%, whichever is greater.
Tolerance is not defined by other ranges.
Alarm limit specifications:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child / neonate: 0 to 150 [1 / min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscilometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Unit of measure: mmHg
Nominal monitoring range:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Medium: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40 - 200 mmHg,
Diastolic: 10 - 150 mmHg,
Medium: 20 - 165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Medium: 20 - 110 mmHg
Alarm limit specifications:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Media: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40-200 mmHg,
Diastolic: 10 - 150 mmHg,
Media: 20-165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Media: 20 - 110 mmHg
Precision:
The mean error must be less than 5 mmHg
The standard deviation must be less than 8 mmHg.
Manual or automatic start of measurement at programmable intervals of 1/2 / 2.5 / 3/4/5/10/15/30/60/90/120/180/240/480 / 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
• Adult: When the cuff pressure exceeds 297 mmHg ± 3mmHg, the control valve will relieve the pressure.
• Child: When the cuff pressure exceeds 240 mmHg ± 3 mmHg, the control valve will relieve the pressure.
• Neonate: When the cuff pressure exceeds 147 mmHg ± 3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement method: direct.
A temperature channel.
Temperature ranges
Range: 0 - 50 ° C
Accuracy: ± 0.1 ° C (probe tolerance only)
Resolution: 0.1 ° C
Maximum and minimum temperature alarms:
Range: 0 - 50 ° C

TECHNICAL SPECIFICATIONS
10.4 "color touch screen with TFT technology Resolution: 800 X 600
Tilted screen for easy observation.
Dimensions: 291.7mm x 250mm x 146.5mm
Weight 3.3 Kg. With battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 - 240 Vac, 50/60 Hz.
C50: Standard: Li-Ion 11.8 V / 2200 mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60 VA

Reserved expansion ports for SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used in animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Bracket for Feas Electrónica LCD multiparametric monitor
Bracket to securely hold the Feas Electronica multiparameter monitor. Allows the equipment to be rotated horizontally to both sides. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Articulated wall bracket for Feas Electrónica LCD multiparametric monitor
Articulated bracket to securely sustain a Feas Electronica multiparametric monitor. It has several degrees of freedom, since it allows the equipment to be rotated in a horizontal direction, on both sides and inclined anteriorly and posteriorly. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Non-invasive pressure cuff hoses, KTMED
Hoses for non-invasive pressure cuff, KTMED
With two quick couplings 3 meters long.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Silicone hose for NIBP, 3m length
Silicone hose to be connected at one end of the cuff used for non-invasive pressure measurement and at the other end to be connected to the multiparametric monitor. Its length is 3 meters, making it easy to carry out the measurement remotely to the equipment.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Silicone hose for irrigation pump (Physiodispenser)
Silicone hose for the irrigation pump of the Physiodispenser Micromotor for dental implantology.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient line of 2,4 m for sidestream Capnography, Feas Electrónica
Disposable accessory to connect the 'T' type nozzle (which joins the respirator and the patient) to the monitoring system. Its extension is 2,4 meters. The use is exclusive for each patient, in Feas Electronica multiparametric monitor.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Feas Electrónica Sidestream CO2 Filter Kit
Composed by:
1 humidity filter for sidestream capnography, Feas Electrónica
and two 13mm filters for sidestream capnography, Feas Electrónica.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Filters kit of 13mm for sidestream capnography Feas Electrónica
Pair of filters to be used in sidestream capnography of Feas Electronica multiparametric monitors. The filters prevent the entry of particles to the components of the measurement system.
13 mm filter.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
VGA/DVI LCD controller kit M.RT2281.E5 with led backligth, driver+keyboard
VGA/DVI LCD controller kit M.RT2281.E5 with led backligth, driver and keyboard.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.