12V x 2,3Ah Shimastu NP 2.3-12 battery (182mmx24mmx61mm)
Shimatsu battery NP 2.3-12
12V x 2,3Ah

It has the following dimensions:
182mmx24mmx61mm (Length x Width x Height)

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Recorder module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

RECORDER
Hotkey to record command.
High resolution thermal array printer.
Recorder speed: 25 mm/s.
Recorded in real time up to 2 selectable waveforms between ECG, RESP, IBP, SpO2 and CO2 waveform.
Prints the table of cardiac output measurement and the waveform of blood temperature, during the injected.
Prints the header with date and time.
Print values of Sweep Speed, Lead, Gain, Respiratory Rate, Heart Rate, Systolic, Diastolic and Mean Pressure, SpO2 and Pulse Rate, EtCO2, FiCO2 and Respiratory Rate (CO2), according recorded waveform.

ACCESSORIE
Roll of Thermal paper of 50mm x 25m, quantity 1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Electrophisiology module for polygraph
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

ELECTROPHYSIOLOGY
- 18 simultaneous channels of intracavitary ECG.
- Calipers on screen for measurement of time between events.
- 12 leads simultaneous surface electrocardiogram
- Up to four channels of invasive blood pressure (2+2 optionals)
- Tabular displaying of Non Invasive Blood Pressure measures.
-Split screen mode
- Allows using one half of the screen for frozen images as a reference, while the other half of the screen continues monitoring in real time.
- Shortcut for curves Configuration allows to:
- Continuous waveform positioning, gain and Clipping.
- Customized label and color for waveforms.
- Triggered sweep display mode
- Storing the patient case studies into a hard disk for transporting to other equipment or to personal computers using a pen drive.
- A Chanel of Spo2.
- Print out of the patient case studies with selection of color and width trace.
- Conection box for Catheters and Cardiac stimulator.
- Recall of recorded diagnosting data in order to perform its revision, with the possibility of modifying gain, position, color and waveform limits (amplitude).
- Shortcut keys.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of energy test module for monophasic defibrillator 3850B
ENERGY VERIFICATION DELIVERED:
The verification or energy test allows to ensure that the equipment is able to deliver energy on pallets or determine if there is a fault. This information is presented on the display of the device and, if it has a recorder (optional), it will record the information of the test result on paper.

If you are interested in buying, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate energy test module for biphasic defibrillator 3850B
ENERGY VERIFICATION DELIVERED:
The verification or energy test allows to ensure that the equipment is able to deliver energy on pallets or determine if there is a fault. This information is presented on the display of the device and, if it has a recorder (optional), it will record the information of the test result on paper.

If you are interested in buying, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Temperature module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

TEMPERATURE
Up to 2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
Resolution: 0.1ºC. Accuracy: ±0.2ºC.
Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

ACCESSORIES
Temperature sensor Feas Electrónica - DB9M/G, quantity 1 or 2 (according to the added channels.).
Derivation box for parameters of Temperature 1 and 2, DB9M connector, quantity 1 (only for two temperature channels installed).


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate SpO2 module for Polygraph Mod. 1405
The next module will allow you to monitor the plethysmographic curve, SpO2 values ​​and Pulse Rate.

OXIMETRY (SpO2)
- SpO2 Range: 0 % to 100%.
- Accuracy:
Adult, 2% from 70% to 100%
Neonatal: 3% from 70% to 100%,
In movement: 3% from 70% to 100%.
- Resolution: 1%.
- Percent oxygen saturation alarm:
Upper limit: 1 -> 100 and lower limit: 0 -> 99.
- Measurement of pulse frequency and alarms from 30 to 250 (1 / min) ± 3 (1 / min) and ± 5 (1 / min) in motion.
- Resolution: 1 (1 / min).

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of SpO2 module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
- SpO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
- Pulse rate:
Range: 20 to 300 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

ACCESSORIES
SpO2 sensor, quantity 1.
SpO2 extension cable, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Non invasive blood pressure module for polygraph
The following module allows to perform Non-Invasive pressure and obtain the measurement of systolic, mean and diastolic pressure.

NON-INVASIVE BLOOD PRESSURE

Display on the screen of the Systolic, Mean and Diastolic Pressure and Pulse Frequency values.
Type of Patient: ADULT OR NEONATAL.
Start mode of the measurement: AUTOMATIC or MANUAL.
Measurement period in automatic mode: 2 min, 3 min, 4 min, 5 min, 10 min, 15 min, 30 min, 60 min and 90min.
Measurement method: Oscilometric.

Resolution of the parameters
Pressure: 1mmHg.
Frecuency to pulse 1 [1 / min].
Transducer accuracy: ± 3mmHg.
Maximum average error: ± 3 mmHg.
Maximum standard deviation: 8mmHg.
These specifications are given for a temperature range between 10ºC and 40ºC and a humidity range between 15% and 85% RH no condensing. The altitude does not affect the measurement because it is relative to the local atmospheric pressure.

Range:
ADULT
- Systolic: 25 mmHg to 265mmHg.
- Diastolic: 12 mmHg to 220mmHg.
- Average: 18 mmHg to 245mmHg.
- Pulse freq: 40 [1/min] to 240 [1/min]
NEONATAL
- Systolic: 25 mmHg to 135mmHg.
- Diastolic: 12 mmHg to 110mmHg.
- Average: 18 mmHg to 120mmHg.
- Pulse freq:40 [1/min] to 240 [1/min]

Maximum inflation pressure:
- Adult: 290 mmHg ± 3mmHg
- Neonatal: 145 mmHg ± 3mmHg
- Initial inflation pressure: Adult: 150 mmHg.
- Neonatal: 70 mmHg.

Display of the last 1440 measurements taken.
Printing: tabular presentation of the measurements.
Deletion of the table of measurements taken.

In case you are interested in buying, we suggest that you send us the serial number of the equipment beforehand to verify that the module can be added to your equipment. When purchasing this module, you must send the equipment to the factory to carry out the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Non Invasive Blood Pressure module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method.
Use: ADULT or NEONATE.
Measurement mode: AUTOMATIC or MANUAL.
Measure unit: mmHg.
Resolution:
- Pressure: 1 mmHg.
- Pulse rate: 1 1/min.
Transductor accuracy: ±3 mmHg.
Ranges:
- PEDIATRIC/ADULT
Systolic pressure: 25 to 265 mmHg.
Diastolic pressure: 12 to 220 mmHg.
Mean pressure: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.
- NEONATE
Systolic pressure: 25 to 135 mmHg.
Diastolic pressure: 12 to 110 mmHg.
Mean pressure: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.
Alarm limits of: Systolic pressure from 20 to 255 mmHg and off.
Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
Protections:
Double protection from over-pressure.
Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
Protection for exceeding time of measurement.

ACCESSORIES
Reusable cuff for NIBP (size to choice), quantity 1.
Silicone hose for NIBP,3m long, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Invasive Blood Pressure module
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

INVASIVE BLOOD PRESSURE (IBP)
Up to 2 channels of invasive blood pressure.
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
Range: -30 to 300 mmHg.
Mode selection for Pressure Ranges: Automatic or Manual.
Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
Measure unit: mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

ACCESSORIES
Pressure transducer adapter cable (DB9/G) to BD transducer, quantity 1 or 2 (according to the added channels.).
Pressure transducer without adaptation B & D DTX plus TNF-R disposable, quantity 1 or 2 (according to the added channels.).
Derivation box for parameters of Pressure 1, Pressure 2 and/or FiO2 with DB9M, quantity 1 (only for two temperature channels installed).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Cardiac Output module with pre-existing temperature channels
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

CARDIAC OUTPUT
Input of patient parameters: Weight, height.
Selection of: Injected volume: 3, 5 and 10 ml.
Catheter Constant K or Computing Constant (CC).
Measurement of temperature in blood and injected.
Calculation of: Body surface.
CO: Volume in litres/min.
SV: Systolic volume.
CI: Cardiac index.
SI: Systolic index.
Waveform graph for blood temperature as a function of time.
Manual or automatic start of the measurement, at perform the injection.

ACCESSORIES
Catheter adapter cable for cardiac output - DB9M/G, quantity 1.
Derivation box for parameters of Temperature 1 and Cardiac Output, DB9M connector, quantity 1 (only for one temperature channels installed).
Derivation box for parameters of Temperature 1, Temperature 2 and Cardiac Output, DB9M connector, quantity 1 (only for two temperature channels installed).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of FiO2 module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

RECORDER
Hotkey to record command.
High resolution thermal array printer.
Recorder speed: 25 mm/s.
Recorded in real time up to 2 selectable waveforms between ECG, RESP, IBP, SpO2 and CO2 waveform.
Prints the table of cardiac output measurement and the waveform of blood temperature, during the injected.
Prints the header with date and time.
Print values of Sweep Speed, Lead, Gain, Respiratory Rate, Heart Rate, Systolic, Diastolic and Mean Pressure, SpO2 and Pulse Rate, EtCO2, FiCO2 and Respiratory Rate (CO2), according recorded waveform.

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES AND O2 MEASUREMENT
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of expired and inspired O2: from 0% to 100%, Resolution: 1%.
Measurement of N2 O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

ACCESSORIES
Tubing straight airway adapter for sidestream capnography Feas Electrónica, quantity 2.
2.4 m CO2 samplig lines for sidestream capnography Feas Electrónica, quantity 2.
Water trap for use in sidestream capnography with anesthetic gases, quantity 2.
Galvanix oxygen sensor, quantity 1.
Roll of Thermal paper of 50mm x 25m, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Mainstream Capnography module for Multiparameter Patient Monitor LCD
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

MAINSTREAM CAPNOGRAPHY
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: ±2 mmHg from 0 to 40 mmHg.
±5% of reading from 41 to 70 mmHg.
Resolution: 1 mmHg.
Calibration: only zero (room air).
Compensation for temperature and atmospheric pressure, O2 y N2O.
Warm-up time <15s, to start measuring, within 2 minutes to obtain values consistent with the specifications.
Waveform response time: less than 60ms.

ACCESSORIES
Reusable airway adapter for Mainstream Capnography sensor, quantity 1.
Mainstream capnography sensor, quantity 1.
Adapter cable for Mainstream Capnography sensor, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of sidestream capnography module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

SIDESTREAM CAPNOGRAPHY
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 170 1/min.
Accuracy: CO2, ±2 mmHg for CO2 < 5%.
< 10% of reading for CO2 > 5%.
Resolution: CO2, 1mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100mmHg and off.
Respiratory Rate minimum and maximum, 0 to 170 1/min and off.
Two calibration points: zero (room air) and gains (5% or 10%).
Compensation for temperature and atmospheric pressure, O2 y N2O.

ACCESSORIES
""T"" type nozzle for sidestream capnography Feas Electrónica, quantity 2.
Moisture filter for sidestream capnography Feas Electrónica, quantity 2.
Patient line of 2.4 m for sidestream capnography Feas Electrónica, quantity 2.
Filters kit of 13mm for sidestream capnography Feas Electrónica, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of sidestream capnography module + N2O + anesthetic gases for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of N2 O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

ACCESSORIES
Tubing straight airway adapter for sidestream capnography Feas Electrónica, quantity 2.
2.4 m CO2 samplig lines for sidestream capnography Feas Electrónica, quantity 2.
Water trap for use in sidestream capnography with anesthetic gases, quantity 2.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate Battery module for LCD multiparmetric monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

BATTERY
14.4V / 8.8Ah Li-ion battery.
Autonomy: 4 hours.
Battery state indication (empty, full, on charge) on screen.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Agreggate 4 patient module for central monitoring station
This module allows you to expand your central monitoring station. When incorporated it will display 4 more beds in the same central.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of adictional invasive pressure module (third and fourth channel) for polygraph
The Polygraph for Hemodynamics and Electrophysiology studies allows the monitoring of up to four isolated invasive pressure channels. By adding this module you will get the third and fourth channel.

If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Accessory to connect the oxygen inspired fraction (FiO2) sensor to the patient circuit. Exclusive use in Feas Electronica multiparametric monitor.

The T-Adapter is designed to be used in conjunction with the oxygen sensor (ref. 10101) in measurement systems of Inspired oxygen fraction (FiO2).

SPECS
T adapter, technical characteristics 22mm (inner diameter, outlet) x 15mm (inner diameter, T) x 22mm (outer diameter, inlet), HDPE material (High Density Polyethylene).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.