    Infusion pump of volumetric type with peristaltic perfusion system that accepts universal type set. Comprehensive and effective solution to optimize infusion therapy in all the units of the Hospitals and Health Centers.

    • Great quality. Easy to use. Menu in Spanish.
    • It has a simple system to calibrate different sets of infusion and can be recorded up to 9 calibrations for different sets.
    • It has a horizontal structure with an effective prevention against the entry of liquids. It can be hung from the serum support or placed on a table or car.
    • High accuracy, due to an intelligent pulsating compensation made by a double micro-processed unit, resulting in a constant flow of high precision infusion.
    • It has five types of infusion mode: Speed ​​mode, Drip mode, Body Weight mode, Time mode and Drug mode.
    • Contains drip sensor.
    • Contains ultrasonic bubble sensor, high sensitivity.
    • It contains a pressure sensor that allows adjustment of 3 levels of occlusion pressure.
    • High definition screen, allows the on-screen display of the controlled / running function.
    • Illuminated alarm panel (up to 12 alarms). Interface for nurse call.
    • Record of 1500 historical events.
    • The following features and functions contribute to make the patient's treatment more pleasant:
    • Preheating function of the infused solution, with constant temperature of the solution.
    • When the pump door is opened, in a dark environment, a light is switched on automatically that allows changing the set or working on the infusion pump without turning on the ambient light.
    • Silent operation and without vibrations, because it is equipped with a high quality motor.
    • External DC power supply input, also works with 12 VDC input.
    • Easy to transport due to its small size and weight (2.5 kg).

    TECHNICAL SPECIFICATIONS
    Specification of IV set: 20 drops / ml or 60 drops / ml.

    Infusion flow rate:
    •Set IV of 20 drops / ml:
    0.1ml / h ~ 1500ml / h.
    1 drops / min ~ 350 drops / min.
    • Set IV of 60 drops / ml:
    0.1ml / h ~ 200ml / h.
    1 drops / min ~ 200 drops / min.
    • When the speed is between 0.1ml / h ~ 99.9ml / h, the infusion flow rate is changed from 0.1ml / h.
    • When the speed is above 100ml / h, the infusion flow rate is changed from 1ml / h.
    • Accuracy: ± 5%.

    Bubble Detector:
    • Ultrasonic detection method: bubbles are detected above 25μl.

    - Occlusion warning speed:
    It can be divided into three ranges as indicated,
    - High (H) 900mmHg ± 200mmHg (120kPa ± 26,7kPa).
    - Central (C) 500mmHg ± 100mmHg (66,7kPa ± 13,3kPa).
    - Low (L) 100mmHg ± 50mmHg (13.3kPa ± 6,6kPa).
    • Flow rate of the Purge Bolus:
    Adjustable between 600ml / h ~ 1000ml / h.
    • Kvo rate (to maintain permeable route):
    Adjustable minimum flow between 0.1ml / h ~ 5ml / h.

    Built-in battery:
    • Ni-Mh, 12 Vdc, 2300 mAh, the recharge cycle can be repeated up to 500 times.
    • Operating time of the battery: with the battery fully charged, it can run continuously for more than 5 hours at a speed of 25ml / h.

    Operation mode:
    Keep going.

    Protection against the ingress of liquids: IPX4 - Protected against splashing water in any direction.

    Historical records:
    You can store the historical records of more than 1500 infusions made.

    Communication link: SN-1500H: RS-232.

    • Supply voltage: 110V ~ to 230V ~ - 50Hz or 60Hz or 12Vcc-5A external.
    • Maximum power: 40 VA.
    • Classification: class I and internally powered.
    • Protection against electric shocks: Type CF.

    WORK ENVIRONMENT:
    Operating conditions:
    • Ambient temperature: + 5ºC to + 40ºC.
    • Relative humidity: 20% to 90%.
    • Atmospheric pressure: 645mmHg (86kPa) to 795mmHg (106kPa).
    Storage conditions:
    • Ambient temperature: -5ºC to + 55ºC.
    • Relative humidity: 0% to 95%.
    • Environmental pressure: 500mmHg (66,7kPa) to 797mmHg (106,3kPa).

    ACCESSORIES INCLUDED
    1 Power cable to line.
    1 user manual.

    CERTIFICATES
    • Certified Quality Standard:
    ISO13485.
    Disp. A.N.M.A.T. 3266/2013: B.P.F.
    Disp. A.N.M.A.T. 2319/02.
    • Safety rules:
    IEC 60601-1 (Eq IRAM 4220-1 and IEC 601-1- Req.
    IEC 60601-1-2 (Electromagnetic Compatibility).
    IEC 60601-2-24 (Infusion Pumps).

    FREQUENT QUESTIONS
    Do you use any brand of infusion set?
    Yes, the pump is not dependent on any brand of supplies. It is recommended that the silicone IV Set be used.

    Can it be used on animals?
    Yes, it can be used on animals.

    The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.

    Documentation of Infusion Pump model SN-1500H, Sino MDT Ltd:

    See User Manual
    Download Certificate ANMAT