    C50 PATIENT MONITOR

    C50 provides the physician with advanced functionalities and monitoring options in order to meet the demands of a wide range of care in any hospital environment.
    It has a 10.4 "" color screen with TFT technology included to facilitate observation.
    Easy use of the menu via rotary knob and touch screen.
    In addition, it has reserved expansion ports for SD card, USB port and network.

    Use Adult, Pediatric, Neonatal

    ELECTROCARDIOGRAM (ECG)
    Heart rate:
    • Adult: 15-300 [1 / min]
    • Neonates / children: 15 - 350 [1 / min]
    Accuracy: ± 1% or ± 1 [1 / min], whichever is greater.
    Resolution: ± 1 [1 / min]
    Gain selection: 1.25mm / mV, 2.5mm / mV, 5.0mm / mV, 10mm / mV, 40mm / mV, Auto.
    Manual replacement.
    Automatic selection of cable to patient.
    3, 5, 12-lead ECG input mode.
    Lead selection:
    1. DI, DII, DIII
    2. DI, DII, DIII, aVR, aVL, aVF and V
    3. DI, DII, DIII, aVR, aVL, aVF and V1 to V6
    Frequency response:
    • Monitoring mode: 0.5-40Hz.
    • Diagnostic mode: 0.05-130Hz.
    • Surgery mode: 1-20Hz.
    • ST mode: 0.05-40hZ.
    Heart rate alarms:
    • Adult: 15 - 300 [1 / min]
    • Neonates / children: 15 - 350 [1 / min]
    Loose electrode detection.
    Pacemaker Pulse Suppression Capability:
    Amplitude of ± 2mV ~ ± 700mV and pulse width of 0.1ms - 2.0ms.

    ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
    Arrhythmia Type: PVC, Asystole, VTac, Tachycardia, Ventricular Tachycardia, Supraventricular Tachycardia, VR, Bigemine, Trigemine, R over T, Bradycardia, Ventricular Bradycardia, Missed Beats, Atrial Fibrillation, Ventricular Fibrillation, Pacemaker Not Captured (PNC) Pacemaker does not dial (PNP).
    ST segment analysis:
    Range: -2mV to + 2mV
    Accuracy: Measurement tolerance within (-0.8 mV) - (+ 0.8 mV) is ± 0.02 mV or ± 10%, whichever is greater. It is not defined for other ranges.
    Resolution: 0.01mV (0.1mm)

    OXYGEN SATURATION
    Plethysmographic curve, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
    COMEN SpO2:
    Range: 0% - 100%
    Adult/Child Accuracy: Within 70% -100%, tolerance is ± 2% (no movement).
    Neonatal Accuracy: Within 70% -100%, tolerance is ± 3% (no movement).
    Resolution: 1%
    Alarm: 0% to 100%

    PULSE FREQUENCY
    COMEN SpO2:
    Range: 20 - 254 [1 / min]
    Resolution: 1 [1 / min]
    Accuracy: ± 2 [1 / min]
    Alarm: 20 to 350 [1 / min]

    RESPIRATORY CURVE
    Impedance method.
    Breathing frequency:
    • Adult monitoring range: 0 to 120 [1 / min]
    • Monitoring range for child/neonate: 0 to 150 [1 / min]
    Within 7 [1 / min] - 150 [1 / min], the measurement error is ± 2 rpm or ± 2%, whichever is greater.
    Tolerance is not defined by other ranges.
    Alarm limit specifications:
    • Adult monitoring range: 0 to 120 [1 / min]
    • Monitoring range for child / neonate: 0 to 150 [1 / min]
    Apnea alarm

    NON-INVASIVE PRESSURE
    Automatic Oscilometric Method
    Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
    Unit of measure: mmHg
    Nominal monitoring range:
    • Adult Range:
    Systolic: 40 - 270 mmHg,
    Diastolic: 10 - 215 mmHg,
    Medium: 20 - 235 mmHg
    • Pediatric Range:
    Systolic: 40 - 200 mmHg,
    Diastolic: 10 - 150 mmHg,
    Medium: 20 - 165 mmHg
    • Neonatal Range:
    Systolic: 40 - 135 mmHg,
    Diastolic: 10 - 100 mmHg,
    Medium: 20 - 110 mmHg
    Alarm limit specifications:
    • Adult Range:
    Systolic: 40 - 270 mmHg,
    Diastolic: 10 - 215 mmHg,
    Media: 20 - 235 mmHg
    • Pediatric Range:
    Systolic: 40-200 mmHg,
    Diastolic: 10 - 150 mmHg,
    Media: 20-165 mmHg
    • Neonatal Range:
    Systolic: 40 - 135 mmHg,
    Diastolic: 10 - 100 mmHg,
    Media: 20 - 110 mmHg
    Precision:
    The mean error must be less than 5 mmHg
    The standard deviation must be less than 8 mmHg.
    Manual or automatic start of measurement at programmable intervals of 1/2 / 2.5 / 3/4/5/10/15/30/60/90/120/180/240/480 / 720min.
    Measurement time under continuous mode: 5 min
    Overpressure protection:
    • Adult: When the cuff pressure exceeds 297 mmHg ± 3mmHg, the control valve will relieve the pressure.
    • Child: When the cuff pressure exceeds 240 mmHg ± 3 mmHg, the control valve will relieve the pressure.
    • Neonate: When the cuff pressure exceeds 147 mmHg ± 3mmHg, the control valve will relieve the pressure.
    Resolution: 1 mmHg.

    TEMPERATURE
    Measurement method: direct.
    A temperature channel.
    Temperature ranges
    Range: 0 - 50 ° C
    Accuracy: ± 0.1 ° C (probe tolerance only)
    Resolution: 0.1 ° C
    Maximum and minimum temperature alarms:
    Range: 0 - 50 ° C

    TECHNICAL SPECIFICATIONS
    10.4 "color touch screen with TFT technology Resolution: 800 X 600
    Tilted screen for easy observation.
    Dimensions: 291.7mm x 250mm x 146.5mm
    Weight 3.3 Kg. With battery
    Power supply: It has an internal battery and an external AC.
    Supply voltage:
    100 - 240 Vac, 50/60 Hz.
    C50: Standard: Li-Ion 11.8 V / 2200 mAh.
    Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
    Consumption: 60 VA

    Reserved expansion ports for SD card, USB port and network.
    Quality standards:
    IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

    OTHER PRODUCT NAMES
    Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

    FREQUENT QUESTIONS
    Can it be used in animals?
    Yes, please let us know when buying and we will make the adaptation of the accessories.


    The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.

    Documentation of Patient Monitor, Multiuparameter, of 10,4", comen, with Batery Li ion include, Touch Screen, Light, model C50 :

    See User Manual