Monthly rent - Emergency trolley CP 2000

https://www.feaselectronica.com.ar/web/image/product.template/87272/image_1920?unique=d1bc50a

Not Available For Sale

    This combination does not exist.

    Terms and Conditions
    30-day money-back guarantee
    Shipping: 2-3 Business Days

    GENERAL CHARACTERISTICS
    * It is characterized by its high precision when carrying out low dosages and its stability in the flow rate. It is used particularly for the infusion of sodium nitroprusside, dopamine, propofol and antibiotics for acute and severe diseases.
    * The equipment can store customized information of syringes form 33 different manufacturers, Weigao and 32 other manufacturers, configurable by the user.
    * The SN-50F66 pump can use 5ml, 10ml, 20ml, 30ml or 50ml sterile and disposable syringes. Automatically recognizes the inserted syringe.
    * The set can store up to 2000 infusion history records, including the following information: injection mode, injection speed, alarm information, total volume injected, line occlusion pressure limir threshold value, limiting quantity, number or syringe and information of the operation.
    * It has the following alarm functions:
    From incorrect position of the syringe.
    Of residual limit.
    Of occlusion.
    End of injection.
    No operation.
    Of empty syringe.
    Flow limit exceeded.
    Disengaged plunger.
    Power cord disconnected.
    Discharged battery.
    Depleted battery.
    Of system error.
    * Battery operating time: from a full charge, the battery can support 5 hours of operation at a rate of 5 ml/h in two channels.
    * Allows battery operation and charging from the car´s 12Vdc connector.

    TECHNICAL SPECIFICATIONS
    Dimensions: (L x W x H)
    3 channel pump: 469mm x 277mm x 207mm
    Weight:
    3-channel pump: 5,4kg (includes support).
    Feeding:
    AC input: 100V~ to 240V~, 50/60 Hz.
    DC input: 12Vcc.
    Battery voltage: 12Vcc.
    Rated power: 40 VA.
    Quality standards: ISO13485, Disp. A.N.M.A.T. 3266/2013: B.P.F. and Disp. A.N.M.A.T. 2319/02; certified.
    Safety Standards: UNE-EN 60601-1.(Eq. IRAM 4220-1 e IEC 601-1),Class I - Prot. Desc. Elect.: CF, UNE-EN 60601-1-2 (Electromagnetic Compatibility).
    Authorized by the A.N.M.A.T.: PM 1125-18.

    ACCESSORIES
    ● 1 Power cord.
    ● 1 User´s Manual.
    ● 1 Content list.
    ● 1 Manufacturing quality certificate.
    ● 1 Warranty card.

    OTHER PRODUCT NAMES
    Volumetric Infusion Pump/ Parenteral Infusion Pump

    FREQUENT QUESTIONS
    Can it be used on animals?
    Yes, it can be used on animals.

    The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.