Gabinete para Desfibrilador DEA 35x35x18 cm, con alarma sonora y lumínica
This cabinet allows a AED Defibtech to be mounted on a wall to increase visibility and to protect the AED from theft or damage.
Infrared Thermometer NewTop, model BZ-R6
INFRARED THERMOMETER FOR NON-CONTACT MEASUREMENT.

- Digital forehead thermometer with non-contact infrared technology.
- Easy to use. Measure temperature simply and quickly with the push of a button. The measurement time is less than 1 second.
- It has a sound fever alert (≥ 37.8ºC).
- Ideal for measuring the temperature in adults, children and babies. It can also measure the temperature on surfaces of objects and liquids. The measurement range in people is from 32ºC to 42.9ºC and the range on surfaces is from 0ºC to 100ºC.
- Accurate measurement. Ideal for taking body temperature with a minimum margin of error (± 0.2º).
- LCD screen illuminated in three colors: green, orange and red.
- Safe and hygienic. Ideal for home and professional use.
- Ability to save up to 32 records in its memory.
- Automatic shutdown after 15 seconds.

TECHNICAL CHARACTERISTICS:
Name: Infrared thermometer.
Model: BZ-R6
Non-contact measurement.
Measuring distance: 3-15cm.
Measurement time: ≤0.5s
Audible fever alert (≥ 37.8ºC)
Measurement range on surfaces: from 0 to 100ºC
Measurement range in people: 32-42.5ºC (89.6-108.5ºF)
Precision:
- Within the range 35-42ºC: ± 0.2ºC
- Outside the range 32-42.9º: ± 0.3ºC
Measurement units: ºC / ºF
Memory for the last 32 measurements
Illuminated LCD screen in three colors: green, orange and red.
Automatic shutdown: 15 seconds.
Weight: 142 gr.
Dimensions: 170 x 95 x 45 mm

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monitoring central station model 5032C Feas Electrónica
The Monitoring central station model 5032C Feas Electronica is a centralized patient monitoring system, composed of a Central Processing Unit (CPU) with CENTRALC software, a color LCD monitor, a keyboard, a mouse, a printer and the necessary wiring for the communication with bedside devices. The Monitoring Central allows monitoring from 4 to 16 patients, through the connection with bedside monitors. Monitors supported include, but are not limited to, the following devices: LCD Multipair Patient Monitor, Defibrillator Monitor 3850B, and FEAS ELECTRONICA Vital Signs Monitors. The connection between the Bedside Monitor and the Monitoring Center allows communication which can be: Analog, Digital and Full Digital.

- Provides simultaneous monitoring of electrocardiogram with indication of heart rate, respiratory curve with indication of respiratory rate and invasive pressure curve, with indication of systolic, diastolic and mean pressure values of up to 16 different patients.
- Ideal for use in intensive care and coronary units.
- Observation of Waveforms: electrocardiogram, invasive blood pressure and respiratory.
- Digital communicaton with bedside feas ELECTRONICA monitors, for the reception of values of: ECG, Respiratory, SpO2, Pulse Rate, EtCO2, Invasive Blood Pressure, Temperature, Non-Invasive Blood Pressure, Fico, and Respiratory Rate.
- Selection of ECG and RESPIRATORY curve gains.
- Auto scale invasive pressure curve.
- Curve sweep speed selection.
- Audible and visual alarms by maximum and minimum, configurable for all the parameters; with volume control.
- Enter text on screen (Patient Case History).
- Freeze waveform of selected patient.
- Observe previous events.
- Trend graphs. Graphic or tabular trend of the last 72 hours, displayed on 1, 4, 8, 12, 24, 48 and 72 hours.
- High resolution printing of: saved waveforms and values for heart rate, systolic, diastolic and mean pressures, respiratory rate and trends for all the parameters.

TECHNICAL SPECIFICATIONS

Analogic Input Signals:
- ECG: 1V/mV.
- PRESSURES: 1V/100 mmHg.
- RESPIRATORY: 1V/3 Ohm.

Digital connection to bedside monitors:
- Display: Color SVGA Monitor Dimensions: 19" (Optional large size).
- CPU: Industrial PC Motherboard. Storage Solid State Disk.
- Output for connecting additional remote monitors.
- Printer: Laser black and white.
- AC Voltge input: 90V-/240V. ~ Frequency 50Hz/60Hz.

ACCESSORIES INCLUDED
- Keyboard, mouse and pad.
- Power cords for CPU, monitor and printer.
- User manual.

AREAS OF USE:
Intensive and intermediate care units, coronary care units, operating rooms, rehabilitation centers, others.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - One-channel syringe infusion pump
RENT
Includes equipment rental. For different rental periods, please consult.

Syringe infusion pump model SN-50C66T is a constant volume, channel and speed controlled infusion pump. It is characterized by high precision, stable flow rate and low dosage.

It is used particularly for the infusion of sodium nitroprusside, dopamine, propofol and antibiotics for acute and serious illnesses. The pump has multiple types of alarm functions to ensure a safe and reliable infusion process.

This product is used to clinically control the flow and velocity of fluids (drugs, nutrients, and blood) infused into the patient's body for safer use.

GENERAL CHARACTERISTICS
* The equipment can store customized syringe information from 33 different manufacturers, Weigao and 32 other manufacturers, configurable by the user.
* SN-50C66T pump can use sterile and disposable syringes of 5ml, 10ml, 20ml, 30ml or 50ml. Automatically recognizes the syringe in place.
* The equipment can store up to 2000 historical infusion records, which include the following information: injection mode, injection rate, alarm information, total volume injected, threshold value of the occlusion pressure limit of the path, limiting quantity, number of syringe and information of the operation.
* It has the following alarm functions:
Incorrect position of the syringe.
Residual limit.
Occlusion.
End of injection.
No operation.
From empty syringe.
Flow limit exceeded.
Plunger decoupled.
Power cord disconnected.
Discharged battery.
Dead battery.
System error.
* Battery operating time: starting from a full charge, the battery can support 6 hours of operation on one channel at a rate of 5 ml / h.
* Allows operation and battery charging from the car's 12Vdc connector.
* Intended User: Adult, Pediatric, Neonatal

TECHNICAL SPECIFICATIONS
* Dimensions:
306mm x 140mm x 146mm (Length x Width x Height)
* Weight: 2.25kg (includes support).
* Electrical feeding:
AC input: 100V to 240V, 50/60 Hz.
DC input: 12Vdc.
Battery voltage: 12Vdc.
Nominal power: 40 VA.

CERTIFICATES:
* Quality standards:
ISO13485
Disp. A.N.M.A.T. 3266/2013: B.P.F.
Disp. A.N.M.A.T. 2319/02
* Safety rules:
UNE-EN 60601-1. (Eq. IRAM 4220-1 and IEC 601-1), Class I - Prot. Desc. Elect .: CF
UNE-EN 60601-1-2 (Electromagnetic Compatibility).
Authorized by the A.N.M.A.T .: PM 1125-18.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Multi uses trolley Model CT62512D3T Feas Electrónica
PRODUCT DESCRIPTION

Rolling unit ideal for use in clinics, sanatoriums, hospitals and health centers in general. Allows organized storage of supplies and placement of equipment on the top shelf
Multipurpose trolley.
Top shelf with protective railing and transparent cover.
Sliding ABS drawer, with internal compartments that allow efficient organization of supplies.
ABS middle shelf.
Bottom shelf made of ABS.
Material: ABS, high impact engineering plastic.
2 garbage cans with lid
4 silent wheels of 13 cm, 2 of them with brakes.
Warranty: 1 year.
Aluminum structure covered with ABS plastic, material resistant to rust and corrosion.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 12,1", Comen, with Batery Li ion include, Touch screen, light, model C80
MULTIPARAMETER MONITOR C80

C80 provides the clinician with advanced functionality and monitoring options to meet the demands of a wide range of care in any hospital setting.
It has a color screen with TFT technology of 10.4" inclined to facilitate observation.
Easy menu use via rotary knob and touch screen.
In addition, it has reserved expansion ports such as for SD card, USB port and network.

Adult, Pediatric, Neonatal Use

ELECTROCARDIOGRAM(ECG)
Heart rate:
•Adult: 15-300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Accuracy: ±1% o ±1 [1/min], whichever is greater.
Resolution: ±1 [1/min]
Gain selection: 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 40mm/mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12 lead ECG input mode.
Selection of leads:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF y V
3. DI, DII, DIII, aVR, aVL, aVF y V1 a V6
Frequency response:
•Monitoring mode: 0.5-40Hz.
•Deagnostic mode: 0.05-130Hz.
•Surgery modality: 1-20Hz.
•ST Mode: 0.05-40hZ.
Heart rate alarms:
•Adult: 15 - 300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ±2mV~±700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia type: PVC, Asystoloe, VTac, Tachycardia, Ventricular tachycardia, Supraventricular tachycardia, VR, Bigeminia, Trigeminia, R on T, Bradycardia, Ventricular bradycardia, missed beats, Atrial fibrillation, Ventricular fibrillation, Non-captured pacemaker (NCP), Non-captured pacemaker (PNP).
ST segment analysis:
Range: -2mV to +2mV
Accuracy: Measurement tolerance within (-0.8 mV)-(+0.8 mV) is ±0.02 mV or ±10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curse, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
Comen SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, the tolerance is ±2% (without movement).
Neonatal Accuracy: within 70% -100%, the tolerance is ±3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE RATE
Comen SpO2:
Range: 20 - 254 [1/min]
Resolution: 1[1/min]
Accuracy: ±2 [1/min]
Alarm: 20 a 350 [1/min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Within 7 [1/min] – 150 [1/min], the measurement error is ±2 rpm or ±2%, whichever is greater.
The tolerance is not defined by other ranges.
Alarm Limit Specification:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscillometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Measurement unit: mmHg
Nominal Monitoring Range:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Alarm Limit Specifications:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric Range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Precision:
The mean error should be less than 5mmHg
The standard deviation should be less than 8mmHg.
Manual or automatic start of measurement at programmable intervals of 1/ 2/ 2.5/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 180/ 240/ 480/ 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
•Adult: When the cuff pressure exceeds 297 mmHg ±3mmHg, the control valve will relieve the pressure.
•Child: When the cuff pressure exceeds 240 mmHg ±3 mmHg, the control valve will relieve the pressure.
•Neonate: When the cuff pressure exceeds 147 mmHg ±3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement Method: direct.
A temperature channel.
Temperature Ranges
Range: 0 - 50° C
Accuracy: ±0.1°C (Exclusive of probe tolerance)
Resolution: 0.1°C
Maximum and minimum temperature alarms:
Range: 0 - 50° C


TECHNICAL SPECIFICATIONS

12.1" color touch screen with TFT technology Resolution: 800 X 600
Inclined screen to facilitate observation.
Dimensions: 344 mm x 291 mm x 165 mm
Weight 3.9 Kg. with battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 – 240 Vac, 50/60 Hz.
C80: Standard: Li-Ion 11.8V/2200mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60VA
Reserved expansion ports such as SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Syringe infusion pump model SN-50C66T: one channel, standard support, with weight mode
Syringe infusion pump model SN-50C66T is a constant volume, channel and speed controlled infusion pump. It is characterized by high precision, stable flow rate and low dosage.

It is used particularly for the infusion of sodium nitroprusside, dopamine, propofol and antibiotics for acute and serious illnesses. The pump has multiple types of alarm functions to ensure a safe and reliable infusion process.

This product is used to clinically control the flow and velocity of fluids (drugs, nutrients, and blood) infused into the patient's body for safer use.

GENERAL CHARACTERISTICS
* The equipment can store customized syringe information from 33 different manufacturers, Weigao and 32 other manufacturers, configurable by the user.
* SN-50C66T pump can use sterile and disposable syringes of 5ml, 10ml, 20ml, 30ml or 50ml. Automatically recognizes the syringe in place.
* The equipment can store up to 2000 historical infusion records, which include the following information: injection mode, injection rate, alarm information, total volume injected, threshold value of the occlusion pressure limit of the path, limiting quantity, number of syringe and information of the operation.
* It has the following alarm functions:
Incorrect position of the syringe.
Residual limit.
Occlusion.
End of injection.
No operation.
From empty syringe.
Flow limit exceeded.
Plunger decoupled.
Power cord disconnected.
Discharged battery.
Dead battery.
System error.
* Battery operating time: starting from a full charge, the battery can support 6 hours of operation on one channel at a rate of 5 ml / h.
* Allows operation and battery charging from the car's 12Vdc connector.
* Intended User: Adult, Pediatric, Neonatal

TECHNICAL SPECIFICATIONS
* Dimensions:
306mm x 140mm x 146mm (Length x Width x Height)
* Weight: 2.25kg (includes support).
* Electrical feeding:
AC input: 100V to 240V, 50/60 Hz.
DC input: 12Vdc.
Battery voltage: 12Vdc.
Nominal power: 40 VA.

CERTIFICATES:
* Quality standards:
ISO13485
Disp. A.N.M.A.T. 3266/2013: B.P.F.
Disp. A.N.M.A.T. 2319/02
* Safety rules:
UNE-EN 60601-1. (Eq. IRAM 4220-1 and IEC 601-1), Class I - Prot. Desc. Elect .: CF
UNE-EN 60601-1-2 (Electromagnetic Compatibility).
Authorized by the A.N.M.A.T .: PM 1125-18.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Training Desfibrillator AED Heart+ResQ NT-381T
A quick guide for the AED training desfibrilator (NT-381 T)

A) Assignment of the identifier
            Press the pediatric mode button and the status button S at the same time.
            When the device turns on, 2 beeps will confirm that it is on and that the process of assigning an identifier has begun.

            1) On the remote control, press the CODE key.
            2) Enter a 2-digit number to assign the desired identifier.
            3) For example 01.02.03 ... 99.
            4) Press ENT to record the entered identifier.

B) Individual control of the DEAs
            Turn on the device and enter the identifier (1 ~ 99) on the remote control and then press the CODE key.

C) Control of several DEAS simultaneously
            Turn on the devices and enter 0 and CODE to simultaneously control these devices regardless of the identifier.

D) Rescue scenarios
            “The team has 11 different scenarios, which are described below.
             Enter the desired scenario number and press the ENT key to save the selection ”.

   Scenario 0 - Defibrillable rhythm
            Press 0 (zero) and then the ENT key to start the scenario.
            The ECG analysis will start automatically after checking the correct placement of the patches 3 times, without pressing any key on the remote control.

   Scenario 1 - Non-defibrillable rhythm
            Press 1 (one) and then the ENT key to start the scenario.
            The ECG analysis will not begin until the instructor presses the NEXT key on the remote control after placing the patches.

   Scenario 2 - Defibrillable rhythm
            Press 2 (two) and then the ENT key to start the scenario.
            The ECG analysis will not begin until the instructor has not pressed the NEXT key on the remote control in the patch placement stage.

   Scenario 3 - Non-defibrillable rhythm
            Press 3 (three) and then the ENT key to start the scenario.
            The ECG analysis will start automatically without inviting to place the patches.

   Scenario 4 - Defibrillable rhythm
            Press 4 (four) and then the ENT key to start the scenario.
            The ECG analysis will start automatically without inviting to place the patches.

   Scenario 5 - Defibrillable rhythm
            Defibrillable rhythm at all times the ECG analysis will start automatically without inviting to place the patches.

   Scenario 6 - CPR (Pulmonary Cardio Resuscitation)

   Scenario 7 - Low battery

   Scenario 8 - An error was detected during the self-diagnosis

   Scenario 9 - Self Diagnosis

   Scenario 10 - PC Mode

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.