Patient Monitor Model PM9000 Feas Electrónica
MULTIPARAMETER PATIENT MONITOR Model: PM9000
GENERAL CHARACTERISTICS
Features:
Menu, messages and instructions in English or Spanish.
Single sweep speeds for circulatory (25mm/s y 50mm/s) and respiratory system (6,25 mm/s, 12,5 mm/s, 25 mm/s y 50 mm/s).
Visual and audible QRS indicator proceeding from ECG or Oxymeter.
When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
Physiological and technical alarms.
Three alarm priority levels: low, medium and high priority.
Upper and lower limits adjustable by the user.
Visual and audible alarm indicators, on screen and on top of the equipment.
Hotkey to pause visual or audible alarms for 2 minutes.
Visual or audible alarms Turn Off function.
User friendly menu by using the trim knob and hotkeys.
Networking Connection for Centralized Monitoring.
Screen menu: - Normal.
- 7 leads of ECG.
- Tabular trends or graphical trends.
- Big numbers
- OxyCRG
BASIC CHANNELS
Electrocardiogram (ECG)
Heart rate: Adult 15 to 300 1/min. Pediatric 15 a 350 1/min
Gain selection: 0.25, 0.5, 1 and 2 cm/mV, individual or for both channels.
Visual and audible QRS indication.
Automatic selection of 3 or 5 leads patient cable.
3 leads with 3 leads patient cable. Lead selection: DI, DII or DIII.
7 leads with 5 leads patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and C.
50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
Heart rate alarms: Lower and upper (medium priority).
Lower and upper extreme (high priority) and off.
Lead off detection.
Pacemaker pulse indication.
Pacemaker pulse rejection in counting the heart rate:
Pulse rejected characteristic: -Amplitude: from ±2 mV to ±700 mV.
-Pulse width: from 0.1 ms to 2.0 ms.
Analysis and classification of arrhythmias
Detected and classified the follow arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy,
Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
Measurement of the S-T segment: both the isoelectric point and the ST point areuser adjustable.
Range: ±2.00 mV. PVCs per minute measurement.

Respiratory waveform (RESP)
Impedancemetry Method.
Measurement selection: Transabdominal (II-F) o Transthoracic (I-L).
Respiratory rate: 5 to 170 1/min.
Apnea Alarm.
Respiratory rate alarm, minimum and maximum: 5 to 170 1/min.

Oxygen saturation (SpO2)
Plethysmographic waveform, Display of percentual oxygen saturation.
Measurement signal low perfusion and motion.
SpO2:
Range: 0% to 100%.
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
Pulse rate:
Range: 20 to 250 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 250 1/min and off.

Two channels of invasive blood pressure (IBP)
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
Range: -30 to 300 mmHg.
Mode selection for Pressure Ranges: Automatic or Manual.
Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
Technical alarm due to transducer failure and disconnected catheter.
Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
Units in mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

Two temperature channels
Compatible with Thermistor Series YSI 400.
Measurement of body temperature (25°C a 50°C) or injectate temperature during measurement of Cardiac Output, from (-10ºC to 25ºC).
Resolution: 0.1ºC. Accuracy: ±0.2ºC.
Temperature Alarm, minimum and maximum:(25ºC to 50ºC) and off.

Cardiac output (CO)
Input of patient parameters: Weight, height.
Selection of: Injectate volume: 3, 5 and 10 ml.
Catheter Constant K or Computing Constant (CC).
Measurement of temperature in blood and injected.
Calculation of: Body surface.
CO: Volume in liters/min.
SV: Systolic volume.
CI: Cardiac index.
SI: Systolic index.
Waveform graph for blood temperature as a function of time.
Manual or automatic start of the measurement, at perform the injection.
Stores 8 measurements.
Blood temperature: Range 15°C to 45°C, resolution 0.01°C and accuracy ±0.3°C.
Injected temperature: Range -10°C to 25°C, resolution 0.1°C and accuracy ±0.4°C.

Non-invasive blood pressure (NIBP)
Oscillometric method
Use: ADULT/PEDIATRIC or NEONATE.
Measurement mode: AUTOMATIC or MANUAL.
Unit in mmHg.
Resolution:
Pressure: 1 mmHg.
Pulse rate: 1 1/min.
Transductor accuracy: ±3 mmHg or ±2%, whichever is greater.
Ranges:
ADULT/PEDIATRIC
Pressure: Systolic: 25 to 265 mmHg.
Diastolic: 12 to 220 mmHg.
Mean: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.

NEONATE
Pressure: Systolic: 25 to 135 mmHg.
Diastolic: 12 to 110 mmHg.
Mean: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.

Alarm limits of: Systolic pressure from 20 to 255 mmHg and off.
Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
Protections: Double protection from over-pressure.
Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
Protection for exceeding the time of measurement.

OPTIONALS
FiO2
Fraction of inspired Oxygen: from 0% to 100%.
Galvanic cell measurement principle.
Alarms minimum and maximum: 18% to 100% and off.

Recorder
Direct access key for record command.
High resolution thermal array printer.
Recorder speed: 25 mm/s.
Recorded in real time up to 2 selectable waveforms between ECG, RESP, IBP,
SpO2 and CO2 waveform.
Prints the header with date and time.
Print values of Sweep Speed, Lead, Gain, Respiratory Rate, Heart Rate,
Systolic, Diastolic and Mean Pressure, SpO2 and Pulse Rate, EtCO2, FiCO2
and Respiratory Rate (CO2), according recorded waveform.

Capnography

Option 1: Sidestream
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate: 4 to 150 1/min.
Accuracy: from 0 mmHg to 38 mmHg: ±2.0 mmHg
from 39 mmHg to 70 mmHg: ±5 mmHg
from 71 mmHg to 100 mmHg: ±8 mmHg
Resolution: CO2, 1mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Calibration: Two zero points -room air and gains (5% or 10%)-.

Option 2: Sidestream with anesthetic gases measurement
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of expired and inspired O2: from 0% to 100%, Resolution: 1%.
Measurement of N2O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

Option 3: Mainstream
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 170 1/min.
Accuracy: ±2 mmHg from 0 to 40 mmHg.
±5% of reading from 41 to 70 mmHg.
Resolution: 1 mmHg.
Calibration: only zero (room air).
Compensation for temperature and atmospheric pressure, O2 y N2O.
Warm-up time <15s, to start measuring, within 2 minutes to obtain values consistent with the specifications.
Waveform response time: less than 60ms.

Touchscreen

ACCESSORIES
Included:
3 or 5 leads patient cable.
Disposable electrodes.
SpO2 sensor.
Pressure Transducer Adaptor (2 units).
Pressure transducer (2 units).
Temperature sensor.
Power cord.
User manual.

TECHNICAL SPECIFICATIONS
15” LCD Color Monitor. Resolution: 1024 x 768. Greater angle of view.
Dimensions: Height: 345mm; Width: 335mm; Depth: 205mm.Weight: 6 Kg.
Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
Power Consumption: 65VA.
Internal Battery: 14.4V / 8.8Ah Li-ion battery. Autonomy: 3.5 hours.
Battery state indication (empty, full, on charge) on screen.
Quality Standard: ISO 13485, Disp. A.N.M.A.T. 3266/2013: B.P.F. and
Disp. A.N.M.A.T. 2319/02, certified.
Safety Standard: UNE-EN60601-1. (Eq. IRAM 4220-1 and IEC 601-1) Electrical-
shock protection: Class I - CF, UNE-EN60601-1-2 (EMC), certified.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, LCD, Feas Electrónica
Feas Electrónica MULTIPAR LCD Patient Monitor is designed for monitoring the vital signs of patients in Intensive Therapies, Coronary Units, Operating Rooms, Emergency Rooms, and in a wide variety of clinical-hospital environments, where several vital signs need to be monitored of a patient simultaneously.

GENERAL CHARACTERISTICS
FUNCTIONS:
• Menu, messages and instructions in English.
• Single sweep speeds for circulatory and respiratory system: 12.5, 25 and 50 mm/s.
• Visual and audible QRS indicator proceeding from ECG or Oxymeter.
• When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
• Three alarm levels: physiologicals, technicals and generals.
• Upper and lower limits adjustable by the user.
• Visual and audible alarm indicators, on screen and on top of the equipment.
• Hotkey to activate the silent alarms for 2 minutes.
• Alarms Turn Off.
• User friendly menu by using the selector knob and hotkeys.
• Waveform print-out on standard printer.
• Analog outputs for ECG, RESP, IBP and a synchronization pulse.
• Networking Connection for Centralized Monitoring.
• WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
• Screen menu: normal, 7 leads of ECG, Tabular trends or graphical trends, frozen and measuring of calipers, large numbers.

BASIC CHANNELS
ELECTROCARDIOGRAM
• Heart rate: 20 to 300 1/min.
• Gain selection: 1/4, 1/2, 1, 2 and 4 cm/mV, individual or for both channels.
Visual and audible QRS indication.
Automatic selection of 3 or 5 leads patient cable.
• 3 leads with 3 wire patient cable. Lead selection: DI, DII or DIII.
12 leads with 5 wire patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and C1, C2, C3, C4, C5 or C6.
50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
• Heart rate alarms, minimum and maximum: 20 to 300 1/min and off.
Lead off detection.
Pacemaker pulse detection.
• Pacemaker pulse rejection in counting the heart rate:
•Pulse rejected characteristic:
- Amplitude: from ±2 mV to ±700 mV
- pulse width: from 0.1 ms to 2.0 ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
• Detects and classifies the following arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy, Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
• Store up to 32 events and allows review and printing.
• Measurement of the S-T segment: both the isoelectric point and the ST point are user adjustable (J-point +60 ms or +80 ms, or any other value in ms, from 1 to 120 ms).
• Range: ±2.00 mV.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
• SpO2:
- Range: 35% to 100%
- Precision:
±2% from 80% to 100%.
±3% from 70% to 79%.
- Resolution: 1%.
- Alarm: 0% to 100% and off.
- Initial alarm: 85%.
• Pulse rate:
- Range: 25 to 250 1/min.
- Precision: ±2 1/min.
- Resolution: 1 1/min.
- Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

Accessories included:
Finger pulse oximeter sensor.

RESPIRATORY WAVEFORM
Impedanciometric method.
• Measurement selection: Transabdominal or Transtoraxic.
• Respiratory rate: 5 to 170 1/min.
Apnea Alarm.
• Respiratory rate alarm, minimum and maximum: 5 to 170 1/min and off.

NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method.
• Use: ADULT or NEONATE.
• Measurement mode: AUTOMATIC or MANUAL.
• Measure unit: mmHg.
• Resolution:
- Pressure: 1 mmHg.
- Pulse rate: 1 1/min.
• Transductor accuracy: ±3 mmHg.
• Ranges:
- PEDIATRIC/ADULT
Systolic pressure: 25 to 265 mmHg.
Diastolic pressure: 12 to 220 mmHg.
Mean pressure: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.
- NEONATE
Systolic pressure: 25 to 135 mmHg.
Diastolic pressure: 12 to 110 mmHg.
Mean pressure: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.
• Alarm limits of:
- Systolic pressure from 20 to 255 mmHg and off.
- Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
• Protections:Double protection from over-pressure.
- Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
- Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
- Protection for exceeding time of measurement.

Accessories included:
Cuff for Non Invasive Blood Pressure.
Hose for Non Invasive Blood Pressure.


INVASIVE BLOOD PRESSURE (IBP) (OPTIONAL)
1 or 2 channels of invasive blood pressure, according to customer's choice.
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
• Range: -30 to 300 mmHg.
• Mode selection for Pressure Ranges: Automatic or Manual.
• Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
• Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
• Measure unit: mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

TEMPERATURE (OPTIONAL)
2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
• Resolution: 0.1ºC.
• Accuracy: ±0.2ºC.
• Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

Accessories included:
Feas Electrónica temperature sensor - DB9M / G.
Derivation box for Temperature 1 and Temperature 2 parameters, DB9M connector (for two Temperature channels).

CARDIAC OUTPUT (OPTIONAL)
• Entry of patient parameters: Weight, height.
• Selection of:
- Injection volume: 3, 5 and 10 ml.
- Catheter Constant K or Computing Constant (CC)
- Measurement of the temperature in blood and injected.
• Calculation of:
- Body surface.
- CO: Volume in liters / min.
- SV: Stroke volume.
- CI: Cardiac index.
- SI: Systolic index.
Waveform graph for blood temperature as a function of time.
Manual or automatic start of the measurement when injecting.

Accessories included:
Catheter adapter cable for cardiac output - DB9M/G
Derivation box for parameters Temperature 1 and Cardiac Output with DB9.
Derivative box for parameters Temperature 1, Temperature 2 and Cardiac Output with DB9.

SIDESTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 170 1 / min.
• Accuracy:
- CO2, ± 2 mmHg for CO2 <5%.
- <10% of reading for CO2> 5%.
• Resolution:
- CO2, 1 mmHg.
- Respiratory Rate, 1 1 / min.
• Alarm:
- FiCO2, EtCO2, minimum and maximum, 0 to 100 mmHg and off.
- Minimum and maximum Respiratory Rate, 0 to 170 1 / min and off.
Calibration: 2 zero points (ambient air) and gain (5% or 10%).
Compensation for temperature and atmospheric pressure, O2 and N2O.

Accessories included:
Type "T" nozzle for Feás Electrónica lateral flow capnography.
2.4 m patient line for Feás Electrónica lateral flow capnography
Moisture filter for lateral flow capnography, Feas Electrónica

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1/min.
• Accuracy: CO2, ±3%ABS.
• Resolution: CO2, 1 mmHg.
- Respiratory Rate, 1 1/min.
• Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
• Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
• Measurement of N2 O: from 0% to 100%.
•Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate:
- 70 to 120 ml/min for neonatal patients.
- 120 to 250 ml/min for adult patients.

Accessories included:
"T" type nozzle for sidestream Capnography, Feas Electrónica.
2,4 m patient line for sidestream Capnography, Feas Electrónica
Water trap for use in lateral flow capnography and anesthetic gases.

MAINSTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1 / min.
• Accuracy: ± 2 mmHg between 0 and 40 mmHg and ± 5% of reading 41 and 70 mmHg.
• Resolution: 1 mmHg.
• Calibration: only zero (ambient air).
Compensation for temperature and atmospheric pressure, O2 and N2O.
Warm-up time <15s, to start measuring, within 2 minutes and obtain measurement values according to specifications.
• Waveform response time: less than 60 ms.

Accessories included:
Mainstream Capnography sensor, Feas Electrónica
Nozzle for mainstream Capnography sensor

FiO2 (OPTIONAL)
Fraction of inspired Oxygen: from 0% to 100%.
Polarographic cell measurement principle.
Alarms minimum and maximum: 0% to 100% and off.

Accessories included:
Derivative box for pressure 1, pressure 2 and / or FiO2 parameters with DB9M.
FiO2 Sensor, Feas Electrónica.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Spiral cable of Oxygen Sensor for FiO2, Feas Electrónica.

ANY OTHER OPTIONAL CHANNEL SPECIFIED CAN BE ADDED IN THE FUTURE.

TECHNICHAL SPECIFICATIONS
15” LCD-TFT Color Monitor
• Resolution: 1024x768.
Wide angle of visibility.
• Dimensions:
- Height: 345mm; Width: 335mm; Depth: 205mm.
• Weight: 6Kg.
• Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
• Power Consumption: 85VA.

CERTIFICATIONS
• Quality Standard (Certificates):
- ISO 13485.
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.

• Safety Standard (Certificates):
- UNE-EN60601-1.(Eq. IRAM 4220-1 and IEC 601-1).
- Electrical-shock protection: Class I – CF.
- UNE-EN60601-1-2 (Electromagnetic compatibility).
Authorized by A.N.M.A.T.: PM 1125-2.

ACCESSORIES
Included:3 or 5 leads patient cable.
Disposable electrodes.
SpO2 sensor.
SpO2 extension cable.
Cuff for NIBP.
Silicone hose for NIBP.
Temperature sensor Feas Electrónica - DB9M/G.
Derivation box for parameters of Temperature 1 and Temperature 2, DB9M connector.
FiO2 Sensor Feas Electrónica.
T Adapter for FiO2 sensor Feas Electrónica.
Spiral cable for FiO2 sensor Feas Electrónica.
Power cord.
User manual.
The image is illustrative.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 10,4", Comen, With Batery Li ion include, Touch screen, Light, model C50
C50 PATIENT MONITOR

C50 provides the physician with advanced functionalities and monitoring options in order to meet the demands of a wide range of care in any hospital environment.
It has a 10.4 "" color screen with TFT technology included to facilitate observation.
Easy use of the menu via rotary knob and touch screen.
In addition, it has reserved expansion ports for SD card, USB port and network.

Use Adult, Pediatric, Neonatal

ELECTROCARDIOGRAM (ECG)
Heart rate:
• Adult: 15-300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Accuracy: ± 1% or ± 1 [1 / min], whichever is greater.
Resolution: ± 1 [1 / min]
Gain selection: 1.25mm / mV, 2.5mm / mV, 5.0mm / mV, 10mm / mV, 40mm / mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12-lead ECG input mode.
Lead selection:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF and V
3. DI, DII, DIII, aVR, aVL, aVF and V1 to V6
Frequency response:
• Monitoring mode: 0.5-40Hz.
• Diagnostic mode: 0.05-130Hz.
• Surgery mode: 1-20Hz.
• ST mode: 0.05-40hZ.
Heart rate alarms:
• Adult: 15 - 300 [1 / min]
• Neonates / children: 15 - 350 [1 / min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ± 2mV ~ ± 700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia Type: PVC, Asystole, VTac, Tachycardia, Ventricular Tachycardia, Supraventricular Tachycardia, VR, Bigemine, Trigemine, R over T, Bradycardia, Ventricular Bradycardia, Missed Beats, Atrial Fibrillation, Ventricular Fibrillation, Pacemaker Not Captured (PNC) Pacemaker does not dial (PNP).
ST segment analysis:
Range: -2mV to + 2mV
Accuracy: Measurement tolerance within (-0.8 mV) - (+ 0.8 mV) is ± 0.02 mV or ± 10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curve, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
COMEN SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, tolerance is ± 2% (no movement).
Neonatal Accuracy: Within 70% -100%, tolerance is ± 3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE FREQUENCY
COMEN SpO2:
Range: 20 - 254 [1 / min]
Resolution: 1 [1 / min]
Accuracy: ± 2 [1 / min]
Alarm: 20 to 350 [1 / min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child/neonate: 0 to 150 [1 / min]
Within 7 [1 / min] - 150 [1 / min], the measurement error is ± 2 rpm or ± 2%, whichever is greater.
Tolerance is not defined by other ranges.
Alarm limit specifications:
• Adult monitoring range: 0 to 120 [1 / min]
• Monitoring range for child / neonate: 0 to 150 [1 / min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscilometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Unit of measure: mmHg
Nominal monitoring range:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Medium: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40 - 200 mmHg,
Diastolic: 10 - 150 mmHg,
Medium: 20 - 165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Medium: 20 - 110 mmHg
Alarm limit specifications:
• Adult Range:
Systolic: 40 - 270 mmHg,
Diastolic: 10 - 215 mmHg,
Media: 20 - 235 mmHg
• Pediatric Range:
Systolic: 40-200 mmHg,
Diastolic: 10 - 150 mmHg,
Media: 20-165 mmHg
• Neonatal Range:
Systolic: 40 - 135 mmHg,
Diastolic: 10 - 100 mmHg,
Media: 20 - 110 mmHg
Precision:
The mean error must be less than 5 mmHg
The standard deviation must be less than 8 mmHg.
Manual or automatic start of measurement at programmable intervals of 1/2 / 2.5 / 3/4/5/10/15/30/60/90/120/180/240/480 / 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
• Adult: When the cuff pressure exceeds 297 mmHg ± 3mmHg, the control valve will relieve the pressure.
• Child: When the cuff pressure exceeds 240 mmHg ± 3 mmHg, the control valve will relieve the pressure.
• Neonate: When the cuff pressure exceeds 147 mmHg ± 3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement method: direct.
A temperature channel.
Temperature ranges
Range: 0 - 50 ° C
Accuracy: ± 0.1 ° C (probe tolerance only)
Resolution: 0.1 ° C
Maximum and minimum temperature alarms:
Range: 0 - 50 ° C

TECHNICAL SPECIFICATIONS
10.4 "color touch screen with TFT technology Resolution: 800 X 600
Tilted screen for easy observation.
Dimensions: 291.7mm x 250mm x 146.5mm
Weight 3.3 Kg. With battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 - 240 Vac, 50/60 Hz.
C50: Standard: Li-Ion 11.8 V / 2200 mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60 VA

Reserved expansion ports for SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used in animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, Comen Model C30
The COMEN C30 Multi-Parameter Patient Monitor is the perfect device to meet all your portable monitoring needs in and out of the hospital. In addition, its hardness and quality allow it to withstand a 1.2 meter drop, making it an excellent portable device that meets the needs of all hospitals. Created for use in adult, pediatric and neonatal patients. It can provide users with all the basic monitoring parameters required by their patients.
Strong, stable, waterproof, dustproof, anti-drop and shockproof.
Small and light, easy to carry.
Suitable for emergency scene, out-of-hospital transport, intra-hospital transport, bedside monitoring in the emergency department

Model C-30
Technical specifications
Security
ISO 13485: 2003 Approved
CE marking according to MDD93 / 42 / EEC

Physical characteristics:
Dimensions: 190mmX81.6mmX107mm
weight: 1.2 kg

Operation Environment
Power: 15Vdc
Power supply: 100-250Vac, 50/60 Hz.
Temperature: 0-40 ° C
Humidity: 15-85%
Battery: Lithium-ion, rechargeable
Plug & play battery, capacity: 2600mA
Maximum of 6.5 hours for charging;
4 hours of continuous work

Specifications
Patient: adult, pediatric, neonate
Display: 4.3 "color TFT touch screen
Resolution: 16:9
2 curves on screen
Sweep speed: 12.5mm / s, 25mm / s, 50mm / s
Indicators:
• Battery indicator light
• Dual indicator alarm light
QRS beep and alarm sound
Key sound
AC input socket
MDR
Trend: 48 hours
Alarm: user adjustable high and low limits
Connection to the monitoring center
DVI connection

Breathing
Impedance method
Rate:
• Adult 0-1OOrpm
• Neonatal 0-150 rpm
• Resolution: ± 1 rpm
Apnea alarm: 10s-40s
Audible and visual alarm
Sweep speed: 12.5.25mm/s
Gain selection: x0.25, x0.5, x1, x2

ECG
Cable: 12-lead CardioTecTM,
3 or 5 snaps (selectable)
12 leads: I, Il, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, -V6
5 wire: RA, LA, RL, LL, V or R, L, N, F, C,
3 wire: RA, LA, LL or R, L, F
Lead Selection: 12 leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
5 wire: I, Il, IIl, aVR, aVL, aVF, V
3 wire: I, Il, III
Gain selection: x0.25, x0.5, x1, x2, auto
Adult: 15-300 1 / min
Pediatric / neonate: 15-350 1 / min
Accuracy: ± 1% or ± 1 1 / min (whichever is greater)
Resolution: 1 1 / min
ECG bandwidth:
MON: 0.5-55Hz
DIA: 0.05-150 Hz
OPE: 1-20Hz
ST segment detection: ± 2.0mV (automatic)
Arrhythmia Analysis
Pacemaker pulse detection

Temperature
2 channels
Standard sensor: Cutaneous
Measurement range: 0-50 ° C
Resolution: 0.1 ° C
Accuracy: 0.1 ° C (excludes sensor error)
Channel: T1, T2, TD (temperature difference)

PNI
Measurement method: Automatic oscillometric
Working mode: manual / automatic / continuous
Interval: Adjustable from 1 min to 480 min
Measurement types: systolic, diastolic, mean
Unit of measure: mmHg / KPa, adjustable
Systolic pressure range:
• Adult: 40 to 270 mmHg
• Pediatric: 40 to 200mmHg
• Neonate: 40 to 135 mmHg
Diastolic pressure range:
• Adult: 10 to 215 mmHg
• Pediatric: 10 to 150mmHg
• Neonate: 10 to 100 mmHg
Medium pressure range:
• Adult: 20 to 235 mmHg
• Pediatric: 20 to 165mmHg
• Neonate: 20 to 110 mmHg
Overpressure Protection: Hardware and Software
• Accuracy: less than ± 5mmHg
• Resolution: 1mmHg

Sp02 Comen
Range: 1-100%
Resolution: 1%
Accuracy:
• ± 2% (70-100%, Ped, no movement)
• ± 3% (70-100%, Neo, no movement)
• 0-69% unspecified
Range alarm: 0-100%
Pulse Frequency:
• Range: 20 to 300 ppm
• Resolution: 1 ppm
• Accuracy:
- ± 3ppm (no movement)
- ± 5ppm (movement)
Alarm: 20 to 300 ppm

EtCO2
Sidestream CO2 (SideStream)
Range: 0 to 150 mmHg, 0 to 79%,
• 0 to 20 kPa (at 760 mmHg)
• Accuracy: ± 2mm Hg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Response time: <240 ms (10% to 90%)
Delay time: <2s

C02 COMEN Main Flow
Range: 0 to 150 mm Hg, 0 to 79%,
0 to 20 kPa (at 760 mmHg)

Accuracy: ± 2mmHg (0-40mmHg)
• ± 5% of reading (41-70 mmHg)
• ± 8% of reading (71-100 mmHg)
• ± 10% of reading (101-150 mmHg)
Frequency: 0-120 rpm
Accuracy:
• ± 2rpm (0-70rpm)
• ± 5 rpm (> 70 rpm)
Delay time: <2s

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, of 12,1", Comen, with Batery Li ion include, Touch screen, light, model C80
MULTIPARAMETER MONITOR C80

C80 provides the clinician with advanced functionality and monitoring options to meet the demands of a wide range of care in any hospital setting.
It has a color screen with TFT technology of 10.4" inclined to facilitate observation.
Easy menu use via rotary knob and touch screen.
In addition, it has reserved expansion ports such as for SD card, USB port and network.

Adult, Pediatric, Neonatal Use

ELECTROCARDIOGRAM(ECG)
Heart rate:
•Adult: 15-300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Accuracy: ±1% o ±1 [1/min], whichever is greater.
Resolution: ±1 [1/min]
Gain selection: 1.25mm/mV, 2.5mm/mV, 5.0mm/mV, 10mm/mV, 40mm/mV, Auto.
Manual replacement.
Automatic selection of cable to patient.
3, 5, 12 lead ECG input mode.
Selection of leads:
1. DI, DII, DIII
2. DI, DII, DIII, aVR, aVL, aVF y V
3. DI, DII, DIII, aVR, aVL, aVF y V1 a V6
Frequency response:
•Monitoring mode: 0.5-40Hz.
•Deagnostic mode: 0.05-130Hz.
•Surgery modality: 1-20Hz.
•ST Mode: 0.05-40hZ.
Heart rate alarms:
•Adult: 15 - 300 [1/min]
•Neonates/children: 15 - 350 [1/min]
Loose electrode detection.
Pacemaker Pulse Suppression Capability:
Amplitude of ±2mV~±700mV and pulse width of 0.1ms - 2.0ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
Arrhythmia type: PVC, Asystoloe, VTac, Tachycardia, Ventricular tachycardia, Supraventricular tachycardia, VR, Bigeminia, Trigeminia, R on T, Bradycardia, Ventricular bradycardia, missed beats, Atrial fibrillation, Ventricular fibrillation, Non-captured pacemaker (NCP), Non-captured pacemaker (PNP).
ST segment analysis:
Range: -2mV to +2mV
Accuracy: Measurement tolerance within (-0.8 mV)-(+0.8 mV) is ±0.02 mV or ±10%, whichever is greater. It is not defined for other ranges.
Resolution: 0.01mV (0.1mm)

OXYGEN SATURATION
Plethysmographic curse, arterial oxygen saturation (SpO2) values, peripheral pulse rate (FFPP) and pulse intensity bar.
Comen SpO2:
Range: 0% - 100%
Adult/Child Accuracy: Within 70% -100%, the tolerance is ±2% (without movement).
Neonatal Accuracy: within 70% -100%, the tolerance is ±3% (no movement).
Resolution: 1%
Alarm: 0% to 100%

PULSE RATE
Comen SpO2:
Range: 20 - 254 [1/min]
Resolution: 1[1/min]
Accuracy: ±2 [1/min]
Alarm: 20 a 350 [1/min]

RESPIRATORY CURVE
Impedance method.
Breathing frequency:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Within 7 [1/min] – 150 [1/min], the measurement error is ±2 rpm or ±2%, whichever is greater.
The tolerance is not defined by other ranges.
Alarm Limit Specification:
•Monitoring range for adult: 0 to 120 [1/min]
•Monitoring range for child/neonate: 0 to 150 [1/min]
Apnea alarm

NON-INVASIVE PRESSURE
Automatic Oscillometric Method
Measurement mode: Manual, auto (cyclical) or continuous (not suitable for neonates)
Measurement unit: mmHg
Nominal Monitoring Range:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Alarm Limit Specifications:
•Adult Range: Systolic: 40 – 270 mmHg,
Diastolic: 10 – 215 mmHg,
Average: 20 – 235 mmHg
•Pediatric Range: Systolic: 40 – 200 mmHg,
Diastolic: 10 – 150 mmHg,
Average: 20 – 165 mmHg
•Neonatal Range: Systolic: 40 – 135 mmHg,
Diastolic: 10 – 100 mmHg,
Average: 20 – 110 mmHg
Precision:
The mean error should be less than 5mmHg
The standard deviation should be less than 8mmHg.
Manual or automatic start of measurement at programmable intervals of 1/ 2/ 2.5/ 3/ 4/ 5/ 10/ 15/ 30/ 60/ 90/ 120/ 180/ 240/ 480/ 720min.
Measurement time under continuous mode: 5 min
Overpressure protection:
•Adult: When the cuff pressure exceeds 297 mmHg ±3mmHg, the control valve will relieve the pressure.
•Child: When the cuff pressure exceeds 240 mmHg ±3 mmHg, the control valve will relieve the pressure.
•Neonate: When the cuff pressure exceeds 147 mmHg ±3mmHg, the control valve will relieve the pressure.
Resolution: 1 mmHg.

TEMPERATURE
Measurement Method: direct.
A temperature channel.
Temperature Ranges
Range: 0 - 50° C
Accuracy: ±0.1°C (Exclusive of probe tolerance)
Resolution: 0.1°C
Maximum and minimum temperature alarms:
Range: 0 - 50° C


TECHNICAL SPECIFICATIONS

12.1" color touch screen with TFT technology Resolution: 800 X 600
Inclined screen to facilitate observation.
Dimensions: 344 mm x 291 mm x 165 mm
Weight 3.9 Kg. with battery
Power supply: It has an internal battery and an external AC.
Supply voltage:
100 – 240 Vac, 50/60 Hz.
C80: Standard: Li-Ion 11.8V/2200mAh.
Once fully charged, it ensures continuous autonomous operation for 2 consecutive hours.
Consumption: 60VA
Reserved expansion ports such as SD card, USB port and network.
Quality standards:
IEC 60601-1, IEC 60601-1-8, IEC 60601-2-27, EN 1060-3, IEC 80601-2-30, IEC60601-2-34, IEC60601-2-49, ISO 80601-2-56, ISO 80601-2-61, Class 1, IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Patient Monitor, Multiparameter, Modular, Comen, Model C90 + C30
COMEN C90 is a device designed to meet the most advanced needs for room monitoring, intermediate care, intensive care, among others. Created to be used in adult, pediatric and neonatal patients. Able to improve in its benefits, according to the needs of the user and the complexity of its clinical unit. This is due to the use of modules for the different extended functions that are required by clinicians.
Features
• It has a C30 multiparameter module, removable and usable as transfer equipment.
• Large high resolution touch screen
• For highly complex monitoring

OTHER PRODUCT NAMES
Multi-Parameter Monitor / Patient Monitor / Vital Signs Monitor / Cardiomonitor

FREQUENT QUESTIONS
Can it be used on animals?
Yes, please let us know when buying and we will make the adaptation of the accessories.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monitoring central station model 5032C Feas Electrónica
The Monitoring central station model 5032C Feas Electronica is a centralized patient monitoring system, composed of a Central Processing Unit (CPU) with CENTRALC software, a color LCD monitor, a keyboard, a mouse, a printer and the necessary wiring for the communication with bedside devices. The Monitoring Central allows monitoring from 4 to 16 patients, through the connection with bedside monitors. Monitors supported include, but are not limited to, the following devices: LCD Multipair Patient Monitor, Defibrillator Monitor 3850B, and FEAS ELECTRONICA Vital Signs Monitors. The connection between the Bedside Monitor and the Monitoring Center allows communication which can be: Analog, Digital and Full Digital.

- Provides simultaneous monitoring of electrocardiogram with indication of heart rate, respiratory curve with indication of respiratory rate and invasive pressure curve, with indication of systolic, diastolic and mean pressure values of up to 16 different patients.
- Ideal for use in intensive care and coronary units.
- Observation of Waveforms: electrocardiogram, invasive blood pressure and respiratory.
- Digital communicaton with bedside feas ELECTRONICA monitors, for the reception of values of: ECG, Respiratory, SpO2, Pulse Rate, EtCO2, Invasive Blood Pressure, Temperature, Non-Invasive Blood Pressure, Fico, and Respiratory Rate.
- Selection of ECG and RESPIRATORY curve gains.
- Auto scale invasive pressure curve.
- Curve sweep speed selection.
- Audible and visual alarms by maximum and minimum, configurable for all the parameters; with volume control.
- Enter text on screen (Patient Case History).
- Freeze waveform of selected patient.
- Observe previous events.
- Trend graphs. Graphic or tabular trend of the last 72 hours, displayed on 1, 4, 8, 12, 24, 48 and 72 hours.
- High resolution printing of: saved waveforms and values for heart rate, systolic, diastolic and mean pressures, respiratory rate and trends for all the parameters.

TECHNICAL SPECIFICATIONS

Analogic Input Signals:
- ECG: 1V/mV.
- PRESSURES: 1V/100 mmHg.
- RESPIRATORY: 1V/3 Ohm.

Digital connection to bedside monitors:
- Display: Color SVGA Monitor Dimensions: 19" (Optional large size).
- CPU: Industrial PC Motherboard. Storage Solid State Disk.
- Output for connecting additional remote monitors.
- Printer: Laser black and white.
- AC Voltge input: 90V-/240V. ~ Frequency 50Hz/60Hz.

ACCESSORIES INCLUDED
- Keyboard, mouse and pad.
- Power cords for CPU, monitor and printer.
- User manual.

AREAS OF USE:
Intensive and intermediate care units, coronary care units, operating rooms, rehabilitation centers, others.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Monthly rent - LCD Multiparameter Patient Monitor ECG/RESP/SPO2/PNI
Includes equipment rental. For different rental periods, please consult

Feas Electrónica MULTIPAR LCD Patient Monitor is designed for monitoring the vital signs of patients in Intensive Therapies, Coronary Units, Operating Rooms, Emergency Rooms, and in a wide variety of clinical-hospital environments, where several vital signs need to be monitored of a patient simultaneously.

GENERAL CHARACTERISTICS
FUNCTIONS:
• Menu, messages and instructions in English.
• Single sweep speeds for circulatory and respiratory system: 12.5, 25 and 50 mm/s.
• Visual and audible QRS indicator proceeding from ECG or Oxymeter.
• When QRS proceeds from the Oxymeter, the sound changes its tone as SpO2 modifies.
• Three alarm levels: physiologicals, technicals and generals.
• Upper and lower limits adjustable by the user.
• Visual and audible alarm indicators, on screen and on top of the equipment.
• Hotkey to activate the silent alarms for 2 minutes.
• Alarms Turn Off.
• User friendly menu by using the selector knob and hotkeys.
• Waveform print-out on standard printer.
• Analog outputs for ECG, RESP, IBP and a synchronization pulse.
• Networking Connection for Centralized Monitoring.
• WAIT Mode: stops monitoring, which allows changing to another patient without activating the alarms.
• Screen menu: normal, 7 leads of ECG, Tabular trends or graphical trends, frozen and measuring of calipers, large numbers.

BASIC CHANNELS
ELECTROCARDIOGRAM
• Heart rate: 20 to 300 1/min.
• Gain selection: 1/4, 1/2, 1, 2 and 4 cm/mV, individual or for both channels.
Visual and audible QRS indication.
Automatic selection of 3 or 5 leads patient cable.
• 3 leads with 3 wire patient cable. Lead selection: DI, DII or DIII.
12 leads with 5 wire patient cable. Lead selection: DI, DII, DIII, aVR, aVL, aVF and C1, C2, C3, C4, C5 or C6.
50Hz or 60Hz Notch filter and Diagnostic, Monitoring or Surgery filter.
• Heart rate alarms, minimum and maximum: 20 to 300 1/min and off.
Lead off detection.
Pacemaker pulse detection.
• Pacemaker pulse rejection in counting the heart rate:
•Pulse rejected characteristic:
- Amplitude: from ±2 mV to ±700 mV
- pulse width: from 0.1 ms to 2.0 ms.

ANALYSIS AND CLASSIFICATION OF ARRHYTHMIAS
• Detects and classifies the following arrhythmias: PVC, PAC, PNC, Bigeminy, Trigeminy, Couple, Run, Tachycardia, Bradycardia, VT, VF and Asystole.
• Store up to 32 events and allows review and printing.
• Measurement of the S-T segment: both the isoelectric point and the ST point are user adjustable (J-point +60 ms or +80 ms, or any other value in ms, from 1 to 120 ms).
• Range: ±2.00 mV.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
• SpO2:
- Range: 35% to 100%
- Precision:
±2% from 80% to 100%.
±3% from 70% to 79%.
- Resolution: 1%.
- Alarm: 0% to 100% and off.
- Initial alarm: 85%.
• Pulse rate:
- Range: 25 to 250 1/min.
- Precision: ±2 1/min.
- Resolution: 1 1/min.
- Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

Accessories included:
Finger pulse oximeter sensor.

RESPIRATORY WAVEFORM
Impedanciometric method.
• Measurement selection: Transabdominal or Transtoraxic.
• Respiratory rate: 5 to 170 1/min.
Apnea Alarm.
• Respiratory rate alarm, minimum and maximum: 5 to 170 1/min and off.

NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method.
• Use: ADULT or NEONATE.
• Measurement mode: AUTOMATIC or MANUAL.
• Measure unit: mmHg.
• Resolution:
- Pressure: 1 mmHg.
- Pulse rate: 1 1/min.
• Transductor accuracy: ±3 mmHg.
• Ranges:
- PEDIATRIC/ADULT
Systolic pressure: 25 to 265 mmHg.
Diastolic pressure: 12 to 220 mmHg.
Mean pressure: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.
- NEONATE
Systolic pressure: 25 to 135 mmHg.
Diastolic pressure: 12 to 110 mmHg.
Mean pressure: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.
• Alarm limits of:
- Systolic pressure from 20 to 255 mmHg and off.
- Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
• Protections:Double protection from over-pressure.
- Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
- Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
- Protection for exceeding time of measurement.

Accessories included:
Cuff for Non Invasive Blood Pressure.
Hose for Non Invasive Blood Pressure.


INVASIVE BLOOD PRESSURE (IBP) (OPTIONAL)
1 or 2 channels of invasive blood pressure, according to customer's choice.
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
• Range: -30 to 300 mmHg.
• Mode selection for Pressure Ranges: Automatic or Manual.
• Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
• Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
• Measure unit: mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

TEMPERATURE (OPTIONAL)
2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
• Resolution: 0.1ºC.
• Accuracy: ±0.2ºC.
• Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

Accessories included:
Feas Electrónica temperature sensor - DB9M / G.
Derivation box for Temperature 1 and Temperature 2 parameters, DB9M connector (for two Temperature channels).

CARDIAC OUTPUT (OPTIONAL)
• Entry of patient parameters: Weight, height.
• Selection of:
- Injection volume: 3, 5 and 10 ml.
- Catheter Constant K or Computing Constant (CC)
- Measurement of the temperature in blood and injected.
• Calculation of:
- Body surface.
- CO: Volume in liters / min.
- SV: Stroke volume.
- CI: Cardiac index.
- SI: Systolic index.
Waveform graph for blood temperature as a function of time.
Manual or automatic start of the measurement when injecting.

Accessories included:
Catheter adapter cable for cardiac output - DB9M/G
Derivation box for parameters Temperature 1 and Cardiac Output with DB9.
Derivative box for parameters Temperature 1, Temperature 2 and Cardiac Output with DB9.

SIDESTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 170 1 / min.
• Accuracy:
- CO2, ± 2 mmHg for CO2 <5%.
- <10% of reading for CO2> 5%.
• Resolution:
- CO2, 1 mmHg.
- Respiratory Rate, 1 1 / min.
• Alarm:
- FiCO2, EtCO2, minimum and maximum, 0 to 100 mmHg and off.
- Minimum and maximum Respiratory Rate, 0 to 170 1 / min and off.
Calibration: 2 zero points (ambient air) and gain (5% or 10%).
Compensation for temperature and atmospheric pressure, O2 and N2O.

Accessories included:
Type "T" nozzle for Feás Electrónica lateral flow capnography.
2.4 m patient line for Feás Electrónica lateral flow capnography
Moisture filter for lateral flow capnography, Feas Electrónica

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1/min.
• Accuracy: CO2, ±3%ABS.
• Resolution: CO2, 1 mmHg.
- Respiratory Rate, 1 1/min.
• Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
• Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
• Measurement of N2 O: from 0% to 100%.
•Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate:
- 70 to 120 ml/min for neonatal patients.
- 120 to 250 ml/min for adult patients.

Accessories included:
"T" type nozzle for sidestream Capnography, Feas Electrónica.
2,4 m patient line for sidestream Capnography, Feas Electrónica
Water trap for use in lateral flow capnography and anesthetic gases.

MAINSTREAM CAPNOGRAPHY (OPTIONAL)
Measurement of EtCO2, FiCO2 and Respiratory Rate.
• Range:
- CO2, from 0 to 100 mmHg (0% to 13%).
- Respiratory Rate, 4 to 150 1 / min.
• Accuracy: ± 2 mmHg between 0 and 40 mmHg and ± 5% of reading 41 and 70 mmHg.
• Resolution: 1 mmHg.
• Calibration: only zero (ambient air).
Compensation for temperature and atmospheric pressure, O2 and N2O.
Warm-up time <15s, to start measuring, within 2 minutes and obtain measurement values according to specifications.
• Waveform response time: less than 60 ms.

Accessories included:
Mainstream Capnography sensor, Feas Electrónica
Nozzle for mainstream Capnography sensor

FiO2 (OPTIONAL)
Fraction of inspired Oxygen: from 0% to 100%.
Polarographic cell measurement principle.
Alarms minimum and maximum: 0% to 100% and off.

Accessories included:
Derivative box for pressure 1, pressure 2 and / or FiO2 parameters with DB9M.
FiO2 Sensor, Feas Electrónica.
Disposable Oxygen Sensor T-adapter for FiO2, Feas Electrónica
Spiral cable of Oxygen Sensor for FiO2, Feas Electrónica.

ANY OTHER OPTIONAL CHANNEL SPECIFIED CAN BE ADDED IN THE FUTURE.

TECHNICHAL SPECIFICATIONS
15” LCD-TFT Color Monitor
• Resolution: 1024x768.
Wide angle of visibility.
• Dimensions:
- Height: 345mm; Width: 335mm; Depth: 205mm.
• Weight: 6Kg.
• Power Supply: 90V~ to 240V~ (with automatic voltage selection) 50Hz or 60Hz.
• Power Consumption: 85VA.

CERTIFICATIONS
• Quality Standard (Certificates):
- ISO 13485.
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.

• Safety Standard (Certificates):
- UNE-EN60601-1.(Eq. IRAM 4220-1 and IEC 601-1).
- Electrical-shock protection: Class I – CF.
- UNE-EN60601-1-2 (Electromagnetic compatibility).
Authorized by A.N.M.A.T.: PM 1125-2.

ACCESSORIES
Included:3 or 5 leads patient cable.
Disposable electrodes.
SpO2 sensor.
SpO2 extension cable.
Cuff for NIBP.
Silicone hose for NIBP.
Temperature sensor Feas Electrónica - DB9M/G.
Derivation box for parameters of Temperature 1 and Temperature 2, DB9M connector.
FiO2 Sensor Feas Electrónica.
T Adapter for FiO2 sensor Feas Electrónica.
Spiral cable for FiO2 sensor Feas Electrónica.
Power cord.
User manual.
The image is illustrative.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.