Electrophysiology and hemodynamic polygraph system mod. 1405 Feas Electrónica
The Polygraph is a system for conducting electrophysiology and hemodynamic studies.

The system is intended to be used in the acquisition, processing and recording of physiological signals. This includes surface electrocardiography (ECG) and intracavitary (IECG, for Electrophysiology only), heart rate, pulse oximetry (optional), invasive and non-invasive pressure (optional), cardiac output and hemodynamic calculations, now the last two for Hemodynamics only.

It is made up of a central data processing unit (CPU), a preamplifier, a color monitor, a laser printer, a keyboard, a mouse and a recording pedal. For Electrophysiology (if applicable), the Polygraph catheter extension box is added.

FEATURES

Hemodynamics
- 2 simultaneous ECG leads on screen, selectable from 12 leads using 10 electrode wires.
- Up to 4 Invasive Pressures.
- Automatic calculation of the fractional flow reserve (FFR) in real time, without the need for an independent (external) FFR analyzer. The FFR allows determining the hemodynamic severity of vascular lesions.
- Numerical and graphic display of the FFR value.
- Study storage.
- Cardiac output by thermodilution. Calculation of BSA, CO, CI, SV, SI.
- Selection of Catheter Constant K.
- Selection of the injection volume.
- Entry of patient data (height and weight).
- Measurement of the temperature of the blood and the injected.
- Curve of blood temperature variation.
- Messages on screen.
- Recording of studies, stores curves and calculations.
- Measurement of body or injection temperature (during cardiac output).
- Allows you to freeze curves and measure times and amplitudes using calipers.
- Printing of frozen curves or recorded studies.
• HEMODYNAMIC CALCULATIONS:
- Aortic valve area.
- Pulmonary valve area.
- Calculation of pulmonary and systemic vascular resistance.

ELECTROPHYSIOLOGY (OPTIONAL)
- 18 simultaneous endocavitational channels.
- Calipers on Screen: allow you to measure time between events of interest.
- 12 simultaneous surface ECG leads.
- Up to 4 Invasive Pressures.
- Tabular presentation of P.N.I.
- Split Screen: allows you to have a frozen reference image in one window, and in the other view the monitoring in real time.
- Quick access to the curve configuration window, where you can make a continuous selection of position, amplitude, filter selection and customize colors and labels of curves.
- Synchronized triggering of the curve sweep (trigger).
- Recording Studies on a hard disk, to be transported to other computers or personal computers using a pen drive.
- One SpO2 channel.
- Study printing with selection of color and line width.
- Catheters connection box and Cardiac Stimulator
- Review of recorded studies, with the possibility of modifying the gain, position, color and limits (of amplitude) of the curves.
- Quick access keys.

Pulse Oximetry (OPTIONAL)
- Plethysmographic curve, visualization of the oxygen saturation percentage.
- Low perfusion and movement signal measurement.
• SpO2:
- Range from 0% to 100%.
- Adult Accuracy: 2% from 70% to 100%.
- Neonatal Accuracy: 3% from 70% to 100%.
- Accuracy in motion: 3% from 70% to 100%.
- Resolution: 1%.
• Pulse Rate:
- Range from 20 [1 / min] to 300 [1 / min].
- Adult Accuracy: ± 3 [1 / min].
- Neonatal precision: ± 3 [1 / min].
- Accuracy in movement: ± 5 [1 / min].
- Resolution: 1 [1 / min].

Non-Invasive Pressure (OPTIONAL)
- Start of measurement manually or automatically at programmable intervals from 2 minutes to 90 minutes.
- Selection of Adult or Neonatal patient.
- Visualization of the last 1440 measurements.
- Printing of measurements in tabular form.
- Includes cuff.

TECHNICAL SPECIFICATIONS
• Screen: LCD monitor 19 ”
- Dimensions: 19 ”(larger size; optional)
- Resolution: 1024 x 768 dots
•CPU:
- Industrial PC motherboard.
- 160 Gb hard disk.
- Output to connect an additional remote monitor.
• Printing machine:
- Laser Technology.
- Resolution 1200 dpi.
• Power supply:
- 110V ~ / 220V ~.
- Frequency 50/60 Hz.

• Quality Standard:
- ISO9001 (certified).
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F. (certificate).
- Disp. A.N.M.A.T. 2319/02 (certified).

• Safety Standard:
- UNE-EN60601-1 (Eq. IRAM 4220-1 and IEC 60601-1) Class I.
- Protection against electric shock: CF.
- Authorized by the A.N.M.A.T. PM 1125-23.

ACCESSORIES INCLUDED
- Preamplifier for Hemodynamic Studies.
- Interconnection cable from CPU to Preamplifier.
- Monitor, keyboard and mouse.
- Cable "Y" Minidin-M to 2 Minidin-F.
- Printing machine.
- Recording pedal with cable.
- CPU, monitor and printer power cables.
- Data cable to printer.
- Ground cable for interconnection between CPU and Preamplifier.
- Metal support for Preamplifier.
- Catheter extension box.
- Interconnection cable for catheter extension box.
- Mini equipment holder.
- TMM Bracket Mounting Clamp for TBC.
- Support plate for 4 transducers.
- Power strip with 5 shots.
- Disposable electrodes.
- 4 disposable pressure transducers.
- 4 interconnection cables from Preamplifier to disposable pressure transducers.
- Parameter derivation box for invasive pressure
- Injection temperature sensor.
- Patient cable with 3, 5 or 10 wires.
- Cardiac output catheter adapter cable.
- Oximeter sensor.
- Oximeter extension cable.
- Reus Adult Cuff.
- Silicone hose for PNI, 3m.
- Digital adapter for pressure guides (FFR).
- Volcano Pressure Guide Adapter Cable (FFR).
- Transport trolley (optional).
- User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer adapter cable (DB9/G) to BD transducer
Pressure transducer adapter cable (DB9/G) to BD transducer

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer without adaptation B & D DTX plus TNF-R disposable
Pressure transducer without adaptation B & D DTX plus TNF-R disposable
Feas Electronica Patient Monitor Accessory.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pressure transducer Edwards PX260
Pressure transducer Edwards PX260 that relay blood pressure information from a pressure monitoring catheter to a patient monitoring system.

Single TruWave disposable pressure transducer with 3cc flush device and IV set

Design features a straight fluid path across the pressure sensor for easy priming and minimal waveform distortion

Gold plated connector wires for high fidelity signal transfer

Snap-tab flush device designed for easy priming and square-wave testing

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PS2 Keyboard for Model 1405 Electrophysiology Polygraph
The keyboard should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405.

The keyboard is used to operate the menu, which allows you to select sweep speed, ECG gains, pressure range, enter cardiac output measurement, freeze curves, perform caliper measurements, print curves, etc.

Use the keyboard to enter text and numbers. You can also activate some functions and start programs using key combinations and the numeric keypad. It also has hotkeys or quick access keys to optimize the user interface.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Intraesophageal/rectal temperature sensor DB9M/G Feas Electrónica
Feas Electrónica Intraesophageal/rectal temperature sensor DB9M/G

The electronic esophageal-rectal temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in the esophagus or in the rectum.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.90m.
Protection against ingress of liquids: IPX2

The Temperature sensor should only be used with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraph and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Temperature sensor Feas Electrónica- PLUG 6.5mm
Feas Electrónica temperature sensor - PLUG 6.5mm

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Cutaneous temperature sensor for Adult/Pediatric/Neonate Feas Electrónica DB9M/G
Feas Electrónica adult cutaneous temperature sensor DB9M/G

The skin temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in Direct mode.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.80m.
Protection against ingress of liquids: IPX1

The temperature sensors must only work with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraphs and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Oximeter sensor, reusable "Y" DB9M/G 3043 Feas Electrónica
Feas Electrónica reusable "Y" oximeter sensor DB9M/G 3043

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Disposable, DB9M/G, Feas ELECTRÓNICA , 520P
Pediatric pulse oximeter sensor DB9M/G

The Oximetry sensor is used for pediatric patient (weighing between 10kg and 50kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electrónica 520N
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electronica 520N

Oximetry sensor is used for neonatal patient (weight < 3kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I

Oximetry sensor is used for infant patient (weighing between 3kg and 20kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H

The Oximetry sensor is used for pediatric patient (weight: 10kg-30kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A

This oximetry sensor is used for adult patients (weighing more than 30 kg) to measure arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pedal for Feas Electrónica equipment with 6,5mm plug, 5m length
Recording pedal for Study Polygraph for Hemodynamics that allows you to start or stop the recording of a study section.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PS2 Mouse for Feas Electrónica equipment
Mouse for Feas Electrónica equipment

The mouse should only be used with the following equipment: Polygraph for Electrophysiology and Hemodynamics studies model 1405, Polygraph for Hemodynamics studies model 1405 and Model 5032C Monitoring Center. The user is responsible for ensuring compatibility between the mouse and the computer.

Cable length: 1.5 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Mounting for side bar of hemodynamic bed for Polygraph preamplifier
Iron structure, which allows to maintain and move the preamplifier of hemodynamic studies through the procedure table. Use in Feas Electronica brand hemodynamic and electrophysiology polygraphs exclusively.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Silicone hose for NIBP, 3m length
Silicone hose to be connected at one end of the cuff used for non-invasive pressure measurement and at the other end to be connected to the multiparametric monitor. Its length is 3 meters, making it easy to carry out the measurement remotely to the equipment.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Installation and start up of Polygraph
PROPOSAL 1
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table in the hemodynamic room or on the track of the same.
Cost:
- Chageable: if the technician must go to the institution to perform the installation
- Free of charge: if telephone or videoconference support is provided from the factory.

PROPOSAL 2
Arrangement of the elements:
• CPU, printer, monitor, mouse and keyboard in cart inside the room,
• Preamplifier under the table inside the Hemodynamics room or on the track of the same.
• repeater monitor hung on existing monitor stand.
Cost:
- Chargeable: if the technician must go to the institution to perform the installation
- Free of charge: if the installation is attended by telephone or videoconference.

PROPOSAL 3
Arrangement of the elements:
• CPU, printer and monitor in bunker,
• wireless mouse and keyboard on the table in the catheterization room or in the bunker,
• Preamplifier under the table inside the hemodynamic room or on the track of the same,
• repeater monitor hung on existing monitor support with connection to bunker.
Cost: with charge, the technician will travel to the institution to carry out the installation.