PACE Model 203 Dual Chamber (DDD) Temporary Cardiac Pacemaker OSYPKA
ARS 684,750.00 ARS 684,750.00 684750.0 ARS *
* El precio no incluye impuestos
The PACE Model 203 Dual Chamber (DDD) Temporary Cardiac Pacemakeris designed for safe and dependable temporary stimulation of the heart for peri/postoperative pacing and/or therapy for conduction defects and rhythm disturbances.

GENERAL CHARACTERISTICS
• Intuitive dial interface allows for fast and easy access to stimulation and sensitivity settings for the atrium and ventricle.
• High Rate funtion provides rapid atrial stimulation of up to 1,000 ppm (adjustable while applying rapid atrial stimulation).
• Just one button push to automatically measure atrial/ventriuclar rates and intervals, P/R wave amplitudes and AV interval.
• Statistical recording and analysis of pacer activity.
• Standard 9 V alkaline battery provides an average of 240 hrs of continuous operation.
• 2 year warranty.

ACCESSORIES
• Myocardial heartwires for temporary pacing (unipolar, bipolar, and quadripolar)
• Transvenous pacing leads for minimally invasive temporary pacing applications
• Extension cables for temporary pacing leads

TECHNICAL SPECIFICATIONS
Dimensions: 212 mm x 96 mm x 51 mm(8.3” x 3.8” x 2.0”).
Weight 490 g (17.28 oz) including battery
Battery Alkaline: 240 hrs (9.0 V)
Basic Rate 30 - 220 ppm
High Pacing Rate 70 - 1000 ppm
Stimulation Amplitude 0.1 - 18 V
Pulse Width 0.05 - 1.5 ms
Sensitivity Atrium: 0.02 - 20 mV
Ventricular: 1.0 - 20 mV
Refractory Period 250 ms
Runaway Protection 200 ppm ±10 ppm
Pacing Modes:
- Primary: DDD, VVI, AAI, VDD
-Supplementary: D00, V00, A00, DVI
-DAI, VAT, AAT, DDD+AT, DAT


PACE 101 single chamber cardiac pacemaker OSYPKA
ARS 311,250.00 ARS 311,250.00 311250.0 ARS *
* El precio no incluye impuestos
GENERAL CHARACTERISTICS
The PACE 101 single-chamber cardiac pacemaker has the reputation of a legendary workhorse - easy to operate, very durable and light weight. It is intended for temporary atrial or ventricular pacing and supports synchronous (VVI, AAI) and asynchronous (V00, A00) operating modes.

Features:
-Basic stimulation frequency up to 180 ppm.
-Large rotating dials for stimulation frequency, sensitivity, amplitude and pacing mode.
-Rapid atrial pacing up to 720 ppm.
-Long battery lifetime: up to 38 days of operation with a single 9V Alkaline battery.
-Four rotational dials for setup up stimulation frequency, amplitude, sensitivity, and pacing mode.
-Sensed intrinsic activity and paced pulses are indicated optically by a light-emitting diode (LED). Additionally, acoustic signals for sensing and pacing events can be switched on and off.
-Automatic surveillance of battery charge condition. Low battery status is indicated optically by a separate LED labeled 'Low Batt./Error' and acoustically by a warning beep.
-Internal error detection. A device error or defect is indicated by a separate LED labeled 'Low Batt./Error'.
-Run-away protection. The stimulation frequency is limited to a maximum of 180 ppm.
-Protective cover of dials. A protective cover safeguards against accidental changes to the device settings.
Protected terminals in combination with the Series XI Extension Cables ensure touch-proof connection of pacemaker and pacing lead system.

TECHNICAL SPECIFICATIONS
- Dimensions: 6 cm x 11.5 cm x 2.2 cm.
- Weight: 170 g (battery included).
- Alkaline battery: 38 days (72 ppm, 8V).
- Basic stimulation range: 30-180 ppm.
- Rapid stimulation range: basic range x2 or x4 (up to 720 ppm).
- Stimulation amplitude: 0.3 - 12 V.
- Pulse width: 0.75 ms.
- Sensitivity: 1.0 mV at 20 mV, asynchronous.
- Refractory period: 250 ms.
- Protection against uncontrolled running: 200 ± 10 [1 / min].
- Ways of marcapaseo: VVI, VOO, AAI, AOO.

INCLUDED ACCESORIES
- Extension cable.
- User's manual.
- Arm Strap.
- Plastic equipment bag.

OPTIONAL GADGETS
Myocardial heartwires for temporary pacing (unipolar, bipolar)•
Transvenous pacing leads for minimally invasive temporary pacing applications•
Extension cables for temporary pacing leads