Temporary Cardiac Pacemaker OSYPKA Dual Chamber Model PACE-203
The PACE Model 203 Dual Chamber (DDD) Temporary Cardiac Pacemakeris designed for safe and dependable temporary stimulation of the heart for peri/postoperative pacing and/or therapy for conduction defects and rhythm disturbances.

GENERAL CHARACTERISTICS
• Intuitive dial interface allows for fast and easy access to stimulation and sensitivity settings for the atrium and ventricle.
• High Rate funtion provides rapid atrial stimulation of up to 1,000 ppm (adjustable while applying rapid atrial stimulation).
• Just one button push to automatically measure atrial/ventriuclar rates and intervals, P/R wave amplitudes and AV interval.
• Statistical recording and analysis of pacer activity.
• Standard 9 V alkaline battery provides an average of 240 hrs of continuous operation.
• 2 year warranty.

ACCESSORIES
• Myocardial heartwires for temporary pacing (unipolar, bipolar, and quadripolar)
• Transvenous pacing leads for minimally invasive temporary pacing applications
• Extension cables for temporary pacing leads

TECHNICAL SPECIFICATIONS
Dimensions: 212 mm x 96 mm x 51 mm(8.3” x 3.8” x 2.0”).
Weight 490 g (17.28 oz) including battery
Battery Alkaline: 240 hrs (9.0 V)
Basic Rate 30 - 220 ppm
High Pacing Rate 70 - 1000 ppm
Stimulation Amplitude 0.1 - 18 V
Pulse Width 0.05 - 1.5 ms
Sensitivity Atrium: 0.02 - 20 mV
Ventricular: 1.0 - 20 mV
Refractory Period 250 ms
Runaway Protection 200 ppm ±10 ppm
Pacing Modes:
- Primary: DDD, VVI, AAI, VDD
-Supplementary: D00, V00, A00, DVI
-DAI, VAT, AAT, DDD+AT, DAT




The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
PACE-101 Single Chamber Cardiac Pacemaker OSYPKA
GENERAL CHARACTERISTICS
The PACE 101 single-chamber cardiac pacemaker has the reputation of a legendary workhorse - easy to operate, very durable and light weight. It is intended for temporary atrial or ventricular pacing and supports synchronous (VVI, AAI) and asynchronous (V00, A00) operating modes.

Features:
-Basic stimulation frequency up to 180 ppm.
-Large rotating dials for stimulation frequency, sensitivity, amplitude and pacing mode.
-Rapid atrial pacing up to 720 ppm.
-Long battery lifetime: up to 38 days of operation with a single 9V Alkaline battery.
-Four rotational dials for setup up stimulation frequency, amplitude, sensitivity, and pacing mode.
-Sensed intrinsic activity and paced pulses are indicated optically by a light-emitting diode (LED). Additionally, acoustic signals for sensing and pacing events can be switched on and off.
-Automatic surveillance of battery charge condition. Low battery status is indicated optically by a separate LED labeled 'Low Batt./Error' and acoustically by a warning beep.
-Internal error detection. A device error or defect is indicated by a separate LED labeled 'Low Batt./Error'.
-Run-away protection. The stimulation frequency is limited to a maximum of 180 ppm.
-Protective cover of dials. A protective cover safeguards against accidental changes to the device settings.
Protected terminals in combination with the Series XI Extension Cables ensure touch-proof connection of pacemaker and pacing lead system.

TECHNICAL SPECIFICATIONS
- Dimensions: 6 cm x 11.5 cm x 2.2 cm.
- Weight: 170 g (battery included).
- Alkaline battery: 38 days (72 ppm, 8V).
- Basic stimulation range: 30-180 ppm.
- Rapid stimulation range: basic range x2 or x4 (up to 720 ppm).
- Stimulation amplitude: 0.3 - 12 V.
- Pulse width: 0.75 ms.
- Sensitivity: 1.0 mV at 20 mV, asynchronous.
- Refractory period: 250 ms.
- Protection against uncontrolled running: 200 ± 10 [1 / min].
- Ways of marcapaseo: VVI, VOO, AAI, AOO.

INCLUDED ACCESORIES
- Extension cable.
- User's manual.
- Arm Strap.
- Plastic equipment bag.

OPTIONAL GADGETS
Myocardial heartwires for temporary pacing (unipolar, bipolar)•
Transvenous pacing leads for minimally invasive temporary pacing applications•
Extension cables for temporary pacing leads

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pacemaker character cable (2 socket 2mm protected - 2 pin bananas macho 2mm unprotected)
Pacemaker character cable (2 socket 2mm protected - 2 pin bananas macho 2mm unprotected)
Length: 1 meter.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
8F peelable hemostatic introducer, with needle and syringe
8F peelable hemostatic introducer, with needle and syringe

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.