Free shipping in the city of Córdoba for purchases over U$D 200

Defibrillator Monitor 3850B Biphasic Feas Electrónica
Feas Electronica Model 3850B Biphasic is an external defibrillator monitor with a rectilinear biphasic waveform of up to 200J, selectable in steps, which allows defibrillation in asynchronous or synchronized mode with the R wave of the patient's ECG for the application of synchronized cardioversion.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow monitoring of heart rate, SpO2 value and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, it can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and optionally the plethysmographic curve, manually when the operator decides or automatically during charging.

FEATURES

MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired through 3 or 5 leads patient cable or through paddles.
• Leads selection:
- With 3 lead cable: DI, DII, DIII and PAL.
- With 5 lead cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
• ECG Gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
• ECG waveform cascade.
• Digital indication of heart rate.
• Low battery indicator.
• Luminous Indicator of battery charging.
• Alarms silence key.
• Alarms for Heart Rate from 20 ppm to 250ppm.

DEFIBRILLATOR
• Biphasic waveform.
• Defibrillator use in three steps:
1- Turn on and select energy.
2- Load.
3- Trigger energy discharge by means of push buttons on paddles or from the keyboard.
• Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules.
• Visual and audible indication of charging process completed.
• Stored energy indication on display.
• Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
• Charge is cancelled internally: When the key DISARM is pressed or when 60 seconds have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF.
In these cases the energy is discharged internally without reaching the paddles.
• Direct or synchronized discharge.
• Visual and audible indication of synchronized mode.
• Discharge capacity: 150 discharges at maximum energy, with fully charged internal battery.
• Charging time to 200 J, less than 6 seconds.
• The equipment has a power test delivered.

RECORDER (OPTIONAL)
• Direct access key for record command.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal array printer.
• Registration speed: 25 mm / s.
• Prints: date and time, energy in joules, Elctrocardiogram waveform, Gain, Heart Rate, Lead, Sweep Speed, Plethysmographics waveform, SPO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: Width: 50 mm and Diameter Max: 45 mm.
Accessory Included:
50 millimeter roll of paper.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SPO2 measurement:
• Range: 0 to 100%.
• Precision:
Adult ± 2% from 70% and 100%.
Neonatal: ± 3% from 70% and 100%.
In movement: ± 3% from 70% and 100%.
• Resolution: 1%.
• Percentual oxygen saturation alarm:
Upper limit: 1 to100.
Lower limit: 0 to 99.
• Pulse Rate and alarms measurement from 30[1/min] to 250 [1/min] ± 3[1/min] and ± 5 [1/min] with movement.
• Resolution: 1 [1/min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm (selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA (selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

TECHNICAL SPECIFICATIONS
• Power input: 90Vac ~ to 240Vac - 50Hz/60Hz or 12 Vcc.
• Rechargeable internal battery, NiMH - 12V, 3500 mAh.
• Power requirement: 180 W (7W during standby).
• Size: 295mm (width) x 200mm (height) x 345mm (length).
• Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
• Quality standards:
- CE Marking, Dir. 93/42 / EEC (certificate).
- ISO13485 (certificate).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.
• Safety rules:
- EN 60601-1 (Eq IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (EMC).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-15.

INCLUDED ACCESSORIES
External paddles for adults and pediatric with coil cable.
Power cable for external +12 power supply.
AC Power cord.
3 or 5 wire cable for patient for ECG.
Disposable electrodes.
User's manual.

The image is illustrative.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Monophasic Feas Electrónica
The model 3850B Monophasic from FEAS ELECTRÓNICA is a monophasic waveform external defibrillator monitor up to 360J, selectable in steps, which allows defibrillation in asynchronous mode or synchronized with the R wave of the patient's ECG for the application of synchronized cardioversion.

It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow monitoring of heart rate, SpO2 value and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, you can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and, optionally, the plethysmographic curve, manually when the operator decides or automatically during charging.

MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired by cable to patient or by paddles.
• Derivations:
- With 3-lead cable: DI, DII, DIII and PAL.
- With 5-lead cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
• Cascade electrocardiogram.
• Digital heart rate indicator.
• Low battery indicator.
• Battery charging indicator light.
• Alarm silence key.
• Heart rate alarms from 20 [beats / min] to 250 [beats / min].
• ECG gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
• Equipment suitable for hospital use.

DEFIBRILLATOR
• Monophasic wave
• Use of the Defibrillator in three steps:
1- Power on and energy selection.
2- Loading.
3- Triggering of energy by means of pushbuttons on paddles or from keyboard.
• Charge selection key in steps: 2, 3, 5, 7, 10, 20, 50, 100, 200, 300 and 360 Joules.
• Auditory and visual indication of end of charge.
• Indication of stored energy on display.
• Triggering energy by simultaneously pressing both paddle pushbuttons or the “SCHOCK” key.
• The internal charge cancellation occurs when the "DISARM" key is pressed or when 60 seconds have elapsed from the end of the energy charge or when the energy selector switch is turned to the "MONITOR" or "OFF" position. Energy is discharged internally without being present in paddles.
• Direct or synchronized discharge.
• Auditory and visual indication of synchronous mode.
• Discharge capacity: 80 discharges at maximum energy, with the internal battery fully charged.
• Charging time at 360 J: less than 6 seconds.
• Connection to internal paddles or defibrillation pads.
• The equipment has a delivered energy test.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm (selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA (selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SpO2 measurement:
• Range: 0% to 100%.
• Accuracy:
Adult: ± 2% between 70% and 100%.
Neonatal: ± 3% between 70% and 100%.
In motion: ± 3% between 70% and 100%.
• Resolution: 1%.
• Percent oxygen saturation alarm
Upper limit: 1 to 100.
Lower limit: 0 to 99.
• Measurement of pulse rate and alarms from 30 to 250 [1 / min] ± 3 [1 / min] and ± 5 [1 / min] in motion.
• Resolution: 1 [1 / min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

REGISTER (OPTIONAL)
• Direct registration key.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal recorder.
• Registration speed: 25 mm / s.
• Prints: date and time, energy in Joules, EKG curve, Gain, Heart rate, Lead, Sweep speed, Plethysmographic curve, SpO2, Pulse rate, Mode, Pacemaker rate, Pacemaker current.
• Paper: width of 50 mm and maximum diameter of 45 mm.
Accessory Included:
50 millimeter roll of paper.

TECHNICAL SPECIFICATIONS
• Supply voltage: 90Vac to 240Vac - 50/60 Hz or 12 Vdc.
• Internal rechargeable NiMh battery - 12V, 3500 mAh.
• Consumption 180 W (7W during standby).
• Size: 295mm (width) x 200mm (height) x 345mm (length).
• Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
• Quality standards:
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.

• Safety rules:
- EN 60601-1 (Eq. IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (Electromagnetic Compatibility).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-4.

ACCESSORIES INCLUDED
External paddle set for adults.
Power cable for external +12 Vdc input.
Line power cable.
Patient cable with 3 or 5 wires for ECG.
10 disposable electrodes.
User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Monophasic for simulation, Feas Electrónica
Simulation defibrillator. DOES NOT DISCHARGE ENERGY.

The Model 3850B Monophasic from Feas Electronica is an external defibrillator monitor with a monophasic waveform up to 360 J, selectable in steps.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow you to monitor your heart rate, SpO2 value, and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, you can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and, optionally, the plethysmographic curve, manually when the operator decides or automatically during charging.


FEATURES
MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired by cable to patient or by paddles.
• Derivations:
With 3-lead cable: DI, DII, DIII and PAL.
With 5-lead cable: DI, DII, DIII, aVR, aVF, aVL, Precordial and PAL.
• Cascade electrocardiogram.
• Digital indication of heart rate.
• Low battery indicator.
• Battery charging indicator light.
• Alarm silence key.
• Heart rate alarms from 20 [1 / min] to 250 [1 / min].
• ECG gain: 1/6, 1 / 4.1 / 2, 1 and 2 [cm / mV].

DEFIBRILLATOR
• Use of the Defibrillator in three steps:
1. Power on and power selection.
2. Loading.
3. Triggering of energy by means of push buttons on paddles or from keyboard.
• Step load selection key: 2, 3, 5, 7, 10, 20, 50,100, 200, 300 and 360 [Joules].
• Auditory and visual indication of end of charge.
• Indication on display of stored energy.
• Energy Trigger by simultaneously pressing both paddle pushbuttons or the “SHOCK”key.
• Internal charge cancellation:
It occurs when the "DISARM" key is pressed or when 60 seconds have elapsed from the end of the energy charge or when the energy selector switch is turned to the "MONITOR" or "OFF" position.
• It does not perform downloads but can, for simulation, be configured as direct or synchronized.
• Auditory and visual indication of synchronous mode.

REGISTER (OPTIONAL)
• Direct registration key.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal recorder.
• Registration speed: 25 mm / s.
• Prints: Date and Time, Energy in Joules, EKC Curve, Gain, Heart Rate, Lead, Sweep Rate, Plethysmographic Curve, SpO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: 50mm width, 45mm maximum diameter.
Accessory Included:
50 millimeter roll of paper.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm. (Selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA. (Selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SpO2 measurement:
• Range 0% to 100%.
• Accuracy:
Adult ± 2% between 70% and 100%.
Neonatal ± 3% between 70% and 100%.
In Motion ± 3% between 70% and 100%.
• Resolution: 1%.
• Percent oxygen saturation alarm:
Upper limit: 1 to 100.
Lower limit: 0 to 99.
• Measurement of pulse rate and alarms from 30 to 250 [1 / min] ± 3 [1 / min] and ± 5 [1 / min] in Motion.
• Resolution: 1 [1 / min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TECHNICAL SPECIFICATIONS
• Supply voltage: 90 Vac to 240 Vac - 50 Hz / 60 Hz, or 12 Vdc.
• Internal rechargeable NiMh battery - 12 V, 3500 mAh.
• Consumption: 10 W.
• Size: 295mm (width) x 200mm (height) x 345mm (depth).
• Weight: 5 Kg (Including external paddles, battery and recorder).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Self Adhesive keypad for Defibrillator 3850B Monophasic, Feas Electrónica
Adhesive keypad for Defibrillator 3850B Monophasic, Feas Electrónica

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Self adhesive keypad with alarm leds for Defibrillator 3850B Monophasic Feas Electrónica
Self-adhesive keyboard in English or Spanish with alarm LEDs for Defibrillator 3850B Monophasic Feas Electronica. To ensure the compatibility of the replacement we will ask you for the serial number of the equipment in which it will be used.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Self Adhesive keypad for Defibrillator 3850B Biphasic Feas Electrónica
Self-adhesive keyboard in English or Spanish for Defibrillator 3850B Biphasic Feas Electronica. To ensure the compatibility of the replacement we will ask you for the serial number of the equipment in which it will be used.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Self-adhesive keyboard with LEDs for 3600 Defibrillator
Self-Adhesive keypad for Defibrillator 3600

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Reusable “Y” Sensor, Neonatal, Foot, Feas ELECTRÓNICA , 518B
The multifunctional and reusable Oximeter sensor is indicated for non-invasive monitoring by continuous sampling of arterial oxygen saturation and pulse rate of newborn patients (weighing less than 5 kg). It can be applied to the foot of the newborn patient. It can also be used in adult and pediatric patients, although the selected application site (finger or toe) should be appropriately sized.
This sensor is designed to be used exclusively in Feas electronica equipment.

It has a length of 1 meter.
Protection against liquids: IPX1

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Oximeter sensor, reusable "Y" DB9M/G 3043 Feas Electrónica
Feas Electrónica reusable "Y" oximeter sensor DB9M/G 3043

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F
Adult Oximeter Finger Sensor DB9M/G Feas Electrónica 512F

The Oximeter sensor is applicable to adult patients (weighing more than 30kg), for non-invasive measurement by continuous sampling of arterial oxygen saturation and pulse rate, in Oximetry Monitoring Systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Disposable, DB9M/G, Feas ELECTRÓNICA , 520P
Pediatric pulse oximeter sensor DB9M/G

The Oximetry sensor is used for pediatric patient (weighing between 10kg and 50kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electrónica 520N
Pulse Oximeter Sensor, Neonatal (< 3kg), Disposable, DB9M/G, Feas Electronica 520N

Oximetry sensor is used for neonatal patient (weight < 3kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I
Pulse Oximeter Sensor, Infant ( 3kg - 20kg ), Disposable, DB9M/G, 520I

Oximetry sensor is used for infant patient (weighing between 3kg and 20kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H
Pulse Oximeter Sensor, Pediatric, Finger, DB9M/G, Feas ELECTRÓNICA , 512H

The Oximetry sensor is used for pediatric patient (weight: 10kg-30kg) to measurement of arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed for use only in feas ELECTRONICA equipments.

The length of the sensor cable is 1 m.
Protection against liquids: IPX1


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A
Pulse Oximeter Sensor, Adult, Disposable, DB9M/G, Feas ELECTRÓNICA , 520A

This oximetry sensor is used for adult patients (weighing more than 30 kg) to measure arterial oxygen saturation and pulse rate, in oximetry monitoring systems. This sensor is designed to be used exclusively in Feas Electronica equipment.

It has a length of 1 meter.
Protection against liquids IPX1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
External paddles for 3850B defibrillator
Part of External Paddles for 3850B Desfibrillator Feas Electronica

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Pair of Electrodes for pacemaker, Gray color, 95mm diameter
Pair of gray electrodes, 95 mm in diameter, for pacemakers.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Thermal paper for ECG 50mm x 25m
Brand Sensitherm
Direct Inscription Electrocardiograph Paper. Thermochemical Type.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Velcro belt for pacer, 3850B defibrillator
Elastic belt of variable length that allows the support of the electodos to carry out the transcutaneous cardiac stimulation in the thorax of the patient.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Calibration and Certificates of Equipment Calibration
This service includes the calibration of the equipment sent and the certification that the equipment is calibrated according to calibrated simulators and analyzers, both traceable to international standards.
If the equipment is not in conditions to be certified, we cannot issue the corresponding certificate. In that case the necessary repair of the equipment will be quoted to ensure the correct operation of the equipment, so it can be certified. Only if it is approved and a correct operation is achieved, certification will be carried out.