Free shipping to Córdoba for purchases over U$D 200

Defibrillator Monitor 3850B Monophasic for simulation, Feas Electrónica

https://feas-electronica-v4-4.odoo.com/web/image/product.template/48768/image_1920?unique=960d186

ARS 2,027,000.00 2027000.0 ARS ARS 2,027,000.00

ARS 0.00

Price does NOT include taxes

Not Available For Sale

  • Country in which it would be used
  • Patient
  • Registrator
  • Pacemaker
  • Oxigen saturation
  • Electrocardiogram cable

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Simulation defibrillator. DOES NOT DISCHARGE ENERGY.

The Model 3850B Monophasic from Feas Electronica is an external defibrillator monitor with a monophasic waveform up to 360 J, selectable in steps.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow you to monitor your heart rate, SpO2 value, and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, you can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and, optionally, the plethysmographic curve, manually when the operator decides or automatically during charging.


FEATURES
MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired by cable to patient or by paddles.
• Derivations:
With 3-lead cable: DI, DII, DIII and PAL.
With 5-lead cable: DI, DII, DIII, aVR, aVF, aVL, Precordial and PAL.
• Cascade electrocardiogram.
• Digital indication of heart rate.
• Low battery indicator.
• Battery charging indicator light.
• Alarm silence key.
• Heart rate alarms from 20 [1 / min] to 250 [1 / min].
• ECG gain: 1/6, 1 / 4.1 / 2, 1 and 2 [cm / mV].

DEFIBRILLATOR
• Use of the Defibrillator in three steps:
1. Power on and power selection.
2. Loading.
3. Triggering of energy by means of push buttons on paddles or from keyboard.
• Step load selection key: 2, 3, 5, 7, 10, 20, 50,100, 200, 300 and 360 [Joules].
• Auditory and visual indication of end of charge.
• Indication on display of stored energy.
• Energy Trigger by simultaneously pressing both paddle pushbuttons or the “SHOCK”key.
• Internal charge cancellation:
It occurs when the "DISARM" key is pressed or when 60 seconds have elapsed from the end of the energy charge or when the energy selector switch is turned to the "MONITOR" or "OFF" position.
• It does not perform downloads but can, for simulation, be configured as direct or synchronized.
• Auditory and visual indication of synchronous mode.

REGISTER (OPTIONAL)
• Direct registration key.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal recorder.
• Registration speed: 25 mm / s.
• Prints: Date and Time, Energy in Joules, EKC Curve, Gain, Heart Rate, Lead, Sweep Rate, Plethysmographic Curve, SpO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: 50mm width, 45mm maximum diameter.
Accessory Included:
50 millimeter roll of paper.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm. (Selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA. (Selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SpO2 measurement:
• Range 0% to 100%.
• Accuracy:
Adult ± 2% between 70% and 100%.
Neonatal ± 3% between 70% and 100%.
In Motion ± 3% between 70% and 100%.
• Resolution: 1%.
• Percent oxygen saturation alarm:
Upper limit: 1 to 100.
Lower limit: 0 to 99.
• Measurement of pulse rate and alarms from 30 to 250 [1 / min] ± 3 [1 / min] and ± 5 [1 / min] in Motion.
• Resolution: 1 [1 / min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TECHNICAL SPECIFICATIONS
• Supply voltage: 90 Vac to 240 Vac - 50 Hz / 60 Hz, or 12 Vdc.
• Internal rechargeable NiMh battery - 12 V, 3500 mAh.
• Consumption: 10 W.
• Size: 295mm (width) x 200mm (height) x 345mm (depth).
• Weight: 5 Kg (Including external paddles, battery and recorder).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.