Derivation box for parameters of Temperature 1, Temperature 2 and Cardiac Output, DB9M connector
Parameter derivation box that allows the connection of two temperature sensors, both cutaneous and esophageal -rectal, and the catheter adapter cable for cardiac output measurement at the same time on the monitor. Exclusive use in Feas Electrónica multiparametric monitoring, under the supervision of personnel trained in health care.

The Derivation Boxes are designed to adapt the FEAS ELECTRÓNICA temperature sensors ref .: 1580, 1586, 1587 and 5871; and the catheter adapter cable ref .: 1581 to the Multipar LCD and PM9000 model monitors from Feas ELECTRÓNICA.

Protection against liquidos: IPX1
Length cable: 0,6 meters

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Temperature 1 and Cardiac Output, DB9M connector
Parameter derivation box that allows the connection of the esophageal-rectal temperature sensor and the catheter adapter cable for cardiac output measurement at the same time on the monitor. Exclusive use in Feas Electrónica multiparametric monitor, under the supervision of personnel trained in health care.

The Derivation Boxes are designed to adapt the FEAS ELECTRÓNICA temperature sensors ref .: 1580, 1586, 1587 and 5871; and the catheter adapter cable ref .: 1581 to the Multipar LCD and PM9000 model monitors from Feas ELECTRÓNICA.

Protection against liquidos: IPX1
Length cable: 0,6 meters

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Pressure 1, Pressure 2 and/or FiO2, DB9M connector
Parameter branch box that allows the connection of two invasive blood pressure transducer adapter cables and the interconnection cable with the fractional inspired oxygen (FiO2) measurement sensor at the same time on the monitor. Exclusive use in Feas Electrónica patient monitor, under supervision of trained health care personnel.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Derivation box for parameters of Pressure 1 and Pressure 2, DB9M connector
Caja derivadora de parámetros que permite la conexión de dos transductores de presión invasiva, al mismo tiempo, en el monitor multiparamétrico. Uso exclusivo en monitor multiparamétrico Feas Electrónica, bajo supervisión de personal capacitado en el cuidado de la salud.
Defibrillator Monitor 3850B Monophasic for simulation, Feas Electrónica
Simulation defibrillator. DOES NOT DISCHARGE ENERGY.

The Model 3850B Monophasic from Feas Electronica is an external defibrillator monitor with a monophasic waveform up to 360 J, selectable in steps.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow you to monitor your heart rate, SpO2 value, and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, you can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and, optionally, the plethysmographic curve, manually when the operator decides or automatically during charging.


FEATURES
MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired by cable to patient or by paddles.
• Derivations:
With 3-lead cable: DI, DII, DIII and PAL.
With 5-lead cable: DI, DII, DIII, aVR, aVF, aVL, Precordial and PAL.
• Cascade electrocardiogram.
• Digital indication of heart rate.
• Low battery indicator.
• Battery charging indicator light.
• Alarm silence key.
• Heart rate alarms from 20 [1 / min] to 250 [1 / min].
• ECG gain: 1/6, 1 / 4.1 / 2, 1 and 2 [cm / mV].

DEFIBRILLATOR
• Use of the Defibrillator in three steps:
1. Power on and power selection.
2. Loading.
3. Triggering of energy by means of push buttons on paddles or from keyboard.
• Step load selection key: 2, 3, 5, 7, 10, 20, 50,100, 200, 300 and 360 [Joules].
• Auditory and visual indication of end of charge.
• Indication on display of stored energy.
• Energy Trigger by simultaneously pressing both paddle pushbuttons or the “SHOCK”key.
• Internal charge cancellation:
It occurs when the "DISARM" key is pressed or when 60 seconds have elapsed from the end of the energy charge or when the energy selector switch is turned to the "MONITOR" or "OFF" position.
• It does not perform downloads but can, for simulation, be configured as direct or synchronized.
• Auditory and visual indication of synchronous mode.

REGISTER (OPTIONAL)
• Direct registration key.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal recorder.
• Registration speed: 25 mm / s.
• Prints: Date and Time, Energy in Joules, EKC Curve, Gain, Heart Rate, Lead, Sweep Rate, Plethysmographic Curve, SpO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: 50mm width, 45mm maximum diameter.
Accessory Included:
50 millimeter roll of paper.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm. (Selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA. (Selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SpO2 measurement:
• Range 0% to 100%.
• Accuracy:
Adult ± 2% between 70% and 100%.
Neonatal ± 3% between 70% and 100%.
In Motion ± 3% between 70% and 100%.
• Resolution: 1%.
• Percent oxygen saturation alarm:
Upper limit: 1 to 100.
Lower limit: 0 to 99.
• Measurement of pulse rate and alarms from 30 to 250 [1 / min] ± 3 [1 / min] and ± 5 [1 / min] in Motion.
• Resolution: 1 [1 / min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TECHNICAL SPECIFICATIONS
• Supply voltage: 90 Vac to 240 Vac - 50 Hz / 60 Hz, or 12 Vdc.
• Internal rechargeable NiMh battery - 12 V, 3500 mAh.
• Consumption: 10 W.
• Size: 295mm (width) x 200mm (height) x 345mm (depth).
• Weight: 5 Kg (Including external paddles, battery and recorder).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Monophasic Feas Electrónica
The model 3850B Monophasic from FEAS ELECTRÓNICA is a monophasic waveform external defibrillator monitor up to 360J, selectable in steps, which allows defibrillation in asynchronous mode or synchronized with the R wave of the patient's ECG for the application of synchronized cardioversion.

It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow monitoring of heart rate, SpO2 value and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, you can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and, optionally, the plethysmographic curve, manually when the operator decides or automatically during charging.

MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired by cable to patient or by paddles.
• Derivations:
- With 3-lead cable: DI, DII, DIII and PAL.
- With 5-lead cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
• Cascade electrocardiogram.
• Digital heart rate indicator.
• Low battery indicator.
• Battery charging indicator light.
• Alarm silence key.
• Heart rate alarms from 20 [beats / min] to 250 [beats / min].
• ECG gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
• Equipment suitable for hospital use.

DEFIBRILLATOR
• Monophasic wave
• Use of the Defibrillator in three steps:
1- Power on and energy selection.
2- Loading.
3- Triggering of energy by means of pushbuttons on paddles or from keyboard.
• Charge selection key in steps: 2, 3, 5, 7, 10, 20, 50, 100, 200, 300 and 360 Joules.
• Auditory and visual indication of end of charge.
• Indication of stored energy on display.
• Triggering energy by simultaneously pressing both paddle pushbuttons or the “SCHOCK” key.
• The internal charge cancellation occurs when the "DISARM" key is pressed or when 60 seconds have elapsed from the end of the energy charge or when the energy selector switch is turned to the "MONITOR" or "OFF" position. Energy is discharged internally without being present in paddles.
• Direct or synchronized discharge.
• Auditory and visual indication of synchronous mode.
• Discharge capacity: 80 discharges at maximum energy, with the internal battery fully charged.
• Charging time at 360 J: less than 6 seconds.
• Connection to internal paddles or defibrillation pads.
• The equipment has a delivered energy test.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm (selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA (selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SpO2 measurement:
• Range: 0% to 100%.
• Accuracy:
Adult: ± 2% between 70% and 100%.
Neonatal: ± 3% between 70% and 100%.
In motion: ± 3% between 70% and 100%.
• Resolution: 1%.
• Percent oxygen saturation alarm
Upper limit: 1 to 100.
Lower limit: 0 to 99.
• Measurement of pulse rate and alarms from 30 to 250 [1 / min] ± 3 [1 / min] and ± 5 [1 / min] in motion.
• Resolution: 1 [1 / min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

REGISTER (OPTIONAL)
• Direct registration key.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal recorder.
• Registration speed: 25 mm / s.
• Prints: date and time, energy in Joules, EKG curve, Gain, Heart rate, Lead, Sweep speed, Plethysmographic curve, SpO2, Pulse rate, Mode, Pacemaker rate, Pacemaker current.
• Paper: width of 50 mm and maximum diameter of 45 mm.
Accessory Included:
50 millimeter roll of paper.

TECHNICAL SPECIFICATIONS
• Supply voltage: 90Vac to 240Vac - 50/60 Hz or 12 Vdc.
• Internal rechargeable NiMh battery - 12V, 3500 mAh.
• Consumption 180 W (7W during standby).
• Size: 295mm (width) x 200mm (height) x 345mm (length).
• Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
• Quality standards:
- ISO13485 (certified).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.

• Safety rules:
- EN 60601-1 (Eq. IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (Electromagnetic Compatibility).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-4.

ACCESSORIES INCLUDED
External paddle set for adults.
Power cable for external +12 Vdc input.
Line power cable.
Patient cable with 3 or 5 wires for ECG.
10 disposable electrodes.
User manual.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Biphasic for simulation, Feas Electrónica
Simulation defibrillator. DOES NOT DISCHARGE ENERGY.

CHARACTERISTICS MONITOR
- Electrocardiogram monitor with LCD screen.
- Electrocardiogram signal acquired by cable to patient or by paddles.
- Derivations:
- With 3-pin cable: DI, DII, DIII and PAL.
- With 5-pin cable : DI, DII, DIII, aVR, aVF, aVL, Precordial and PAL.
- Cascade electrocardiogram.
- Digital indication of heart rate.
- Low battery indicator.
- Battery charge indicator light.
- Alarm silence key.
- Heart rate alarms from 20 [1/min] to 250 [1/min].
- ECG gain: 1/6, 1/4,1/2, 1 and 2 [cm/mV].

DEFIBRILLATOR
- Use of the defibrillator in three steps:
1. Power on and power selection.
2. Charge.
3. Energy release by means of pushbuttons on paddles or from the keyboard.
- Step load selection key: 2, 3, 5, 7, 10, 20, 50,100, 200, 300 and 360 [Joules].
- Audible and visual indication of end of charge.
- Indication on display of stored energy.
- Energy Trigger by simultaneously pressing both paddle pushbuttons or the “SHOCK” key.
- Internal charge cancellation:
Occurs when the "CANCEL CHARGE" key is pressed or when 60 seconds elapse from the end of the energy charge or when the energy selector key is turned to the "MONITOR" or "OFF" position.
- It does not perform downloads but can, for the simulation, be configured as free or synchronized.
- Audible and visual indication of synchronous mode.

RECORDER
- Direct registration key.
- Automatic registration before an event.
- High resolution thermal recorder.
- Registration speed: 25 mm/s.
- Prints: Date and time, energy in Joules, Electrocardiogram curve, Gain, Heart rate, Lead, Sweep Speed, Plethysmographic curve, SpO2, Pulse Rate, Mode, Pace Rate, Pace Current.
- Paper: Width of 50 mm, Maximun diameter of 45 mm.

TRANSCUTANEOUS PACEMAKER
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (Selectable in steps of 5 ppm).
- Current: 10 mA to 200 mA. (Selectable in 5 mA steps).
- Mode: Selectable, on demand of fixed.
- Pulse width: 20 ms ± 5%.

OXYGEN SATURATION (SpO2)
- SpO2 measurement:
- Range 0% a 100%.
- Accuracy:
Adult ±2% between 70% and 100%.
Neonatal ±3% between 70% and 100%.
Moving ±3% between 70% and 100%.
- Resolution: 1%.
- Percentage oxygen saturation alarm:
Upper limit: from 1 to 100.
Lower limit: from 0 to 99.
- Measurement of pulse rate and alarms from 30 to 250 [1/min] ±3 [1/min] and ±5 [1/min] in Movement.
- Resolution: 1 [1/min].

TECHNICAL SPECIFICATIONS
- Supply voltage: 90 Vca a 240 Vca - 50 Hz/60 Hz, or 12 Vcc.
- Internal rechargeable NiMh battery - 12 V, 3500 mAh.
- Consumption: 10 W.
- Size: 295mm (width) x 200mm (height) x 345mm (depth).
- Weight: 5 Kg (Including external paddles, battery and recorder).

ACCESSORIES INCLUDED
- 1 Set of external padles for adults with spiral cable.
- 1 Power cable for external +12 Vdc input.
- 1 Power line cable.
- 1 Patient cable with 3 clips or 5clips for ECG.
- 10 disposable electrodes.
- 1 User Manual.
- 1 Set of electrodes and 1 elastic belt.
- 1 roll of 50 mm paper.
- 1 Oximetry clamp sensor, adult or pediatric.
- 1 Oximetry sensor extension.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Defibrillator Monitor 3850B Biphasic Feas Electrónica
Feas Electronica Model 3850B Biphasic is an external defibrillator monitor with a rectilinear biphasic waveform of up to 200J, selectable in steps, which allows defibrillation in asynchronous or synchronized mode with the R wave of the patient's ECG for the application of synchronized cardioversion.
It allows the monitoring and surveillance of ECG, with heart rate measurement, through the paddles, or cable to patient with 3 lead or 5 lead.

In addition, optionally, you can monitor pulse oximetry, graphing the plethysmographic curve on the screen and a pulse width indicator bar, indicating the SpO2 and pulse rate values. Both ECG and SpO2 monitoring allow the setting of alarms that allow monitoring of heart rate, SpO2 value and pulse rate.

It is of the portable type, powered by an internal rechargeable battery, a 90 Vac - 240 Vac, 50 Hz or 60 Hz mains supply or an external 12 Vdc source.
Optionally, it has a transcutaneous pacemaker that allows temporary electrical stimulation to the patient in a non-invasive way, in fixed mode (asynchronous) or on demand (synchronous), using electrodes.

Optionally, it can also have a thermal recorder for real-time recording of up to two curves, an ECG lead, and optionally the plethysmographic curve, manually when the operator decides or automatically during charging.

FEATURES

MONITOR
• Electrocardiogram monitor with LCD screen.
• Electrocardiogram signal acquired through 3 or 5 leads patient cable or through paddles.
• Leads selection:
- With 3 lead cable: DI, DII, DIII and PAL.
- With 5 lead cable: DI, DII, DIII, aVR, aVF, aVL, precordial and PAL.
• ECG Gain: 1/6, 1/4, 1/2, 1 and 2 cm / mV.
• ECG waveform cascade.
• Digital indication of heart rate.
• Low battery indicator.
• Luminous Indicator of battery charging.
• Alarms silence key.
• Alarms for Heart Rate from 20 ppm to 250ppm.

DEFIBRILLATOR
• Biphasic waveform.
• Defibrillator use in three steps:
1- Turn on and select energy.
2- Load.
3- Trigger energy discharge by means of push buttons on paddles or from the keyboard.
• Selector switch for charge selection by steps: 2, 3, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200 Joules.
• Visual and audible indication of charging process completed.
• Stored energy indication on display.
• Energy discharge through paddles by pushing, simultaneously, both pushbuttons on paddles.
• Charge is cancelled internally: When the key DISARM is pressed or when 60 seconds have elapsed since charge process was completed or when selector switch is turned to MONITOR or OFF.
In these cases the energy is discharged internally without reaching the paddles.
• Direct or synchronized discharge.
• Visual and audible indication of synchronized mode.
• Discharge capacity: 150 discharges at maximum energy, with fully charged internal battery.
• Charging time to 200 J, less than 6 seconds.
• The equipment has a power test delivered.

RECORDER (OPTIONAL)
• Direct access key for record command.
• Automatic registration when the power charge process starts up to 20 seconds after pressing the Shock key.
• High resolution thermal array printer.
• Registration speed: 25 mm / s.
• Prints: date and time, energy in joules, Elctrocardiogram waveform, Gain, Heart Rate, Lead, Sweep Speed, Plethysmographics waveform, SPO2, Pulse Rate, Mode, Pacemaker Rate, Pacemaker Current.
• Paper: Width: 50 mm and Diameter Max: 45 mm.
Accessory Included:
50 millimeter roll of paper.

OXYGEN SATURATION (SpO2) (OPTIONAL)
SPO2 measurement:
• Range: 0 to 100%.
• Precision:
Adult ± 2% from 70% and 100%.
Neonatal: ± 3% from 70% and 100%.
In movement: ± 3% from 70% and 100%.
• Resolution: 1%.
• Percentual oxygen saturation alarm:
Upper limit: 1 to100.
Lower limit: 0 to 99.
• Pulse Rate and alarms measurement from 30[1/min] to 250 [1/min] ± 3[1/min] and ± 5 [1/min] with movement.
• Resolution: 1 [1/min].
Accessories included:
Oximetry Sensor Extender
Choice of adult or pediatric, clip-on or disposable oximetry sensor.

TRANSCUTANEOUS PACEMAKER (OPTIONAL)
• External stimulation through electrodes.
• Frequency: 40 ppm to 180 ppm (selectable in steps of 5 ppm).
• Current: 10 mA to 200 mA (selectable in steps of 5 mA).
• Mode: Selectable, on demand or fixed.
• Pulse width: 20 ms ± 5%.
Accessories included:
Elastic belt for external Pacemaker electrode.
Pacemaker lead cable.
Pair of gray electrodes.

TECHNICAL SPECIFICATIONS
• Power input: 90Vac ~ to 240Vac - 50Hz/60Hz or 12 Vcc.
• Rechargeable internal battery, NiMH - 12V, 3500 mAh.
• Power requirement: 180 W (7W during standby).
• Size: 295mm (width) x 200mm (height) x 345mm (length).
• Weight: 6 kg (including external paddles, battery and recorder).

CERTIFICATIONS
• Quality standards:
- CE Marking, Dir. 93/42 / EEC (certificate).
- ISO13485 (certificate).
- Disp. A.N.M.A.T. 3266/2013: B.P.F.
- Disp. A.N.M.A.T. 2319/02.
• Safety rules:
- EN 60601-1 (Eq IRAM 4220-1 and IEC 601-1).
- EN 60601-1-2 (EMC).
- EN 60601-1-6.
- EN 60601-1-8.
- EN 60601-2-4.
- EN 60601-2-27.
- EN 60601-2-49.
- ISO 80601-2-61.
Authorized by the A.N.M.A.T. PM-1125-15.

INCLUDED ACCESSORIES
External paddles for adults and pediatric with coil cable.
Power cable for external +12 power supply.
AC Power cord.
3 or 5 wire cable for patient for ECG.
Disposable electrodes.
User's manual.

The image is illustrative.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Cutaneous temperature sensor for Adult/Pediatric/Neonate Feas Electrónica DB9M/G
Feas Electrónica adult cutaneous temperature sensor DB9M/G

The skin temperature probe or sensor is used in monitoring systems to measure body temperature in critical patients, in Direct mode.
In addition, the probe can be used to measure the injected temperature in Cardiac Output.

Sensor cable length: approximately 2.80m.
Protection against ingress of liquids: IPX1

The temperature sensors must only work with the following equipment: Vital Signs Monitors Mod. Multipar LCD and PM9000, Electrophysiology Polygraphs and Hemodynamic Polygraphs; all with manufacturing date of 2005 and later.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Color video extension cable, 15m, injected

Video extension cable injected.

Length: 15 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Clamp electrodes for pediatric patients
4 Clamp electrodes to perform electrocardiograms in pediatric patients.
Visual color code according to IEC standards. Color coding: Red R, Yellow L, Green F, Black N.
Only suitable for use by health professionals.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Clamp electrodes for adult patients
Clamp electrodes set for adult patient.
Visual color code according to IEC standards. Color coding: Red R, Yellow L, Green F, Black N.
Product only suitable for use by health personnel and health institutions.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Catheter adapter cable for cardiac output - DB9M/G
Catheter adapter cable for cardiac output - DB9M/G

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Calibration and Certificates of Equipment Calibration
This service includes the calibration of the equipment sent and the certification that the equipment is calibrated according to calibrated simulators and analyzers, both traceable to international standards.
If the equipment is not in conditions to be certified, we cannot issue the corresponding certificate. In that case the necessary repair of the equipment will be quoted to ensure the correct operation of the equipment, so it can be certified. Only if it is approved and a correct operation is achieved, certification will be carried out.
Cable to patient with Din 3.0mm for electrocardiograph (ECG) brand (Dong Jiang), model 11B
PRODUCT DESCRIPTION
Cable to patient with Din 3.0mm for electrocardiograph brand (Dong Jiang) model 11B
Warranty: 3 months.

OTHER PRODUCT NAMES
Patient Cable / 10 Lead Cable / ECG Cable / EKG Cable

FREQUENT QUESTIONS
What places do you ship to? We ship to all provinces of Argentina and abroad.

For other questions about the product please contact us.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Bracket for Feas Electrónica LCD multiparametric monitor
Bracket to securely hold the Feas Electronica multiparameter monitor. Allows the equipment to be rotated horizontally to both sides. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Battery pack non-rechargable Li-MnO2 12Vcc/4200mAh for AED Feas Electrónica, Model Heart+ResQ
Non-rechargeable battery for AED Feas Electrónica, model Heart + ResQ NT-381.C
Item code: 19122
Type: Battery
Technology: Li-MnO2
Model: Original
Voltage: 12Vcc
Capacity: 4200mAh
Weight (kg): 0.260

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Bag for AED, Red (indeer use) 28 x 24 x 6 cm, Feas Electrónica
Automatic External Defibrillators (AEDs) bag.
It is intended to contain an automatic defibrillator and its accessories, during transport.
It can be used with various brands of AED Defibrillators and it is easily identifiable.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.