Automatic External Defibrillator (AED) Feas Electrónica, model: Heart+ ResQ NT-381.C
Heart + ResQ NT-381.C is an AED (Automatic External Defibrillator) that provides defibrillation treatments for the rapid resuscitation of the patient in SCA (Sudden Cardiac Arrest). This product is portable, battery operated. It is lightweight and can be operated even by users who have received little or no education / training on the use of the product, through voice prompts that guide the user through the operating sequences.

SCA (Sudden Cardiac Arrest) is the cessation of normal blood circulation due to heart failure. SCA can happen to anyone, anytime, anywhere. Patients with SCA do not show any warning signs or previous symptoms. Some are at higher risk for SCA than others, due to hereditary causes or other reasons.

GENERAL CHARACTERISTICS
Defibrillator
• Waveform: truncated exponential biphasic.
• 150 J (Adult, impedance 50 Ω).
• 50 J (Pediatric, impedance 50 Ω).
Charging time: 9 seconds (± 10 %).
• Shock method: manual button (flashes when ready).
• Mode conversion: Adult/Child toggle button.
(Child Mode delivers 50J Pediatric shock for patients weighing less than 25 Kg, approximately 12 months to 8 years old).

ECG
• ECG record: LEAD II.
• Analysis overview: Patient evaluated to determine whether ECG rhythm represents shockable or non-shockable state. Shockable rhythms are ventricular fibrillation.
• Analysis time: Approximately 7 seconds.

Battery Check
• Battery reserve level:
High: 3 bars.
Medium: 2 bars.
Low: 1 bar, red status led.
Critical: no bars, red status led.
• Battery status audible warnings.
Critical: Voice prompt states “Replace the battery”.

Data
• Stored data: ECG recordings, operation information (whether power is delivered or not), ambient noise, self diagnostic history.
• Memory capacity:
- ECG: Consecutively make records during analysis and CPR (once in every 5 s, up to 5000 s).
- Audio recording: 60 min in total (4 recording files of 15 min).
- Self-diagnosis: 3000 cases and results.
• Storage type: Internal memory.
• Access/search: “NT-ADV” software (for PC), via Bluethooth.

Audible and Visual Instructions
• After the equipment is switched on, the voice instructions will guide the operator through the resuscitation process, including the positioning of the patches, the indication of “Don’t touch the patient” (during the energy analysis and discharge process) and CPR (Cardio-Pulmonary Resuscitation) instructions.
• The CPR instructions tell the operator when to start Cardio-Pulmonary Resuscitation, according to the AHA Guide.

TECHNICAL SPECIFICATIONS
• Dimensions: 220 mm (W) x 282 mm (L) x 80 mm (H).
• Weight: 2 Kg (including battery and pads).
• Internal non-rechargeable Li-MnO2 battery - 12 Vdc/4200 mAh.
• Protection against ingress of liquids: IPX5 according to IEC60529.
• Temperature:
Storage: 15 ºC to 55 ºC.
Operation: 0 ºC to 45 ºC.
• Humidity:
Storage: 0 % to 95 % (without condensation).
Operation: 0 % to 90 % (without condensation).
• Altitude (Storage/Operation): 0 to 5000 meters.
• Drop test: 1.5 m according to IEC 60068-2-32.
• Quality standards:
ISO 13485 (certified).
Available A.N.M.A.T. 3266/2013: B.P.F.
Available A.N.M.A.T. 2319/02.
• Safety standards:
- IEC 60601-1 (Eq. IRAM 4220-1 and IEC 601-1).
- IEC 60601-1-2 (Electromagnetic Compatibility).
- IEC 60601-1-6.
- IEC 60601-1-11.
- IEC 60601-2-4.

ACCESSORIES INCLUDED
- Electrode pads
• Shelf life: 2 (two) years.
• Single use.
• Cable length: 2.1 m (± 1 %).
• Applicable ages: All ages (12 months & older).
• Sealing: Airtight.
• Size: 125 mm x 95 mm.
• Pads placement:
Adult: anterior-lateral.
Pediatric: anterior-posterior (see positioning details on the package label).
- 1 Battery Pack
• Type: non-rechargeable Lithium-Manganese Dioxide (Li-MnO2).
• Voltage: 12 Vdc/4200 mAh.
• Standby mode life: Recommended five (5) years at 25 ºC.
• Capacity: 180 shocks @ 25 ºC, 130 shocks at 0 ºC.
• Measures: 22 mm (H) x 164 mm (W) x 54 mm (D).
• Weight: 260 g (±10 %).
- 1 User manual
- 1 bag
- Event Reading Software

OPTIONAL
USB/Bluetooth adapter.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Assembled battery pack Ni-Mh, 12V-4000mAh
Assembled Ni-Mh battery pack, 12V - 4000mAh.
12 months warranty.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Articulated wall bracket for Feas Electrónica LCD multiparametric monitor
Articulated bracket to securely sustain a Feas Electronica multiparametric monitor. It has several degrees of freedom, since it allows the equipment to be rotated in a horizontal direction, on both sides and inclined anteriorly and posteriorly. It can be fixed to all types of walls. It is provided with all the supplies for its placement.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Analog interconnection cable between CPU and preamplifier of Electrophysiology and Hemodynamics Polygraph / SpO2 / PNI
Analog interconnection cable between CPU and Electrophysiology and Hemodynamics Polygraph preamplifier / SpO2 / PNI
The length of the cable is adaptable to the installation, with lengths of 5, 8, 9 and 10 meters.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
American standard Power cord 110V plug NEMA 5-15p 3 pin Feas Electrónica
Feas Electronica equipment power cable with American plug NEMA 5-15p 3 pin

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Agreggate 4 patient module for central monitoring station
This module allows you to expand your central monitoring station. When incorporated it will display 4 more beds in the same central.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of sidestream capnography module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

SIDESTREAM CAPNOGRAPHY
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 170 1/min.
Accuracy: CO2, ±2 mmHg for CO2 < 5%.
< 10% of reading for CO2 > 5%.
Resolution: CO2, 1mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100mmHg and off.
Respiratory Rate minimum and maximum, 0 to 170 1/min and off.
Two calibration points: zero (room air) and gains (5% or 10%).
Compensation for temperature and atmospheric pressure, O2 y N2O.

ACCESSORIES
""T"" type nozzle for sidestream capnography Feas Electrónica, quantity 2.
Moisture filter for sidestream capnography Feas Electrónica, quantity 2.
Patient line of 2.4 m for sidestream capnography Feas Electrónica, quantity 2.
Filters kit of 13mm for sidestream capnography Feas Electrónica, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of sidestream capnography module + N2O + anesthetic gases for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES MEASUREMENT
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of N2 O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

ACCESSORIES
Tubing straight airway adapter for sidestream capnography Feas Electrónica, quantity 2.
2.4 m CO2 samplig lines for sidestream capnography Feas Electrónica, quantity 2.
Water trap for use in sidestream capnography with anesthetic gases, quantity 2.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of pacemaker module for Desfibrillator 3850B
If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

TRANSCUTANEOUS PACEMAKER
- Pacemaker electrode output: Type CF.
- External stimulation through electrodes.
- Frequency: 40 ppm to 180 ppm. (adjustable in steps of 5 ppm).
- Current: 10 mA to 200 mA (adjustable in steps of 5 mA).
- Mode: Selectable, demand or asynchronous.
- Pulse width: 20 ms ± 5%.
- Frequency Accuracy: Within ±5% of displayed value.
-Pacemaker current accuracy: From 10mA to 45mA is ±5mA.
From 50 mA to 200mA is 10%
-Refractory period: 340 ms for frequencies less than or equal to 80 ppm, 240 ms for frequencies greater than 80 ppm.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of energy test module for monophasic defibrillator 3850B
ENERGY VERIFICATION DELIVERED:
The verification or energy test allows to ensure that the equipment is able to deliver energy on pallets or determine if there is a fault. This information is presented on the display of the device and, if it has a recorder (optional), it will record the information of the test result on paper.

If you are interested in buying, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of blood oxygen saturation module for Desfibrillator 3850B
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
- SpO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
- Pulse rate:
Range: 20 to 300 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

ACCESSORIES
SpO2 sensor, quantity 1.
SpO2 extension cable, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of adictional invasive pressure module (third and fourth channel) for polygraph
The Polygraph for Hemodynamics and Electrophysiology studies allows the monitoring of up to four isolated invasive pressure channels. By adding this module you will get the third and fourth channel.

If you are interested in buying, we suggest you to send us the defibrillator's serial number beforehand to ensure compatibility and verify that your equipment can support the module. When purchasing this module you must send the defibrillator to factory to make the corresponding modifications.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Temperature module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

TEMPERATURE
Up to 2 channels of temperature.
Compatible with Thermistor Series YSI 400.
Measurement of body temperature or injectate temperature during measurement of Cardiac Output, from -5ºC to 45ºC.
Resolution: 0.1ºC. Accuracy: ±0.2ºC.
Temperature Alarm, minimum and maximum: -5ºC to 45ºC and off.

ACCESSORIES
Temperature sensor Feas Electrónica - DB9M/G, quantity 1 or 2 (according to the added channels.).
Derivation box for parameters of Temperature 1 and 2, DB9M connector, quantity 1 (only for two temperature channels installed).


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of SpO2 module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

OXYGEN SATURATION
Plethysmographic waveform, display of oxygen saturation (SpO2).
Measurement signal low perfusion and motion.
- SpO2:
Range: 0% to 100%
Adult precision: 2% from 70% to 100%.
Neonate precision: 3% from 70% to 100%.
Motion precision: 3% from 70% to 100%.
Resolution: 1%.
Alarm: 0% to 100% and off.
Initial alarm: 85%.
- Pulse rate:
Range: 20 to 300 1/min.
Adult precision: ±3 1/min.
Neonate precision: ±3 1/min.
Motion precision: ±5 1/min.
Resolution: 1 1/min.
Alarm: 20 to 300 1/min and off.
Waveform gain adjustment x1/2, x1 and x2.

ACCESSORIES
SpO2 sensor, quantity 1.
SpO2 extension cable, quantity 1.


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Recorder module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

RECORDER
Hotkey to record command.
High resolution thermal array printer.
Recorder speed: 25 mm/s.
Recorded in real time up to 2 selectable waveforms between ECG, RESP, IBP, SpO2 and CO2 waveform.
Prints the table of cardiac output measurement and the waveform of blood temperature, during the injected.
Prints the header with date and time.
Print values of Sweep Speed, Lead, Gain, Respiratory Rate, Heart Rate, Systolic, Diastolic and Mean Pressure, SpO2 and Pulse Rate, EtCO2, FiCO2 and Respiratory Rate (CO2), according recorded waveform.

ACCESSORIE
Roll of Thermal paper of 50mm x 25m, quantity 1.

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Recorder module for Desfibrillator 3850B
RECORDER
- Registration hotkey.
- High resolution thermal array printer.
-Resolution
Y axis: 8 points per mm.
X axis: 16 points per mm.
- Paper: width: 50 mm, maximum diameter: 45 mm.
-Printing width: 48 mm.
- Registration speed: 25 mm/s.
- Records the type of patient, the date, the time and in real time, 1 or 2 curves: electrocardiogram and percentage oxygen saturation or cascade electrocardiogram.
-A 50mm x 25m roll of thermal paper is delivered for the UC50 recorder


The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Non Invasive Blood Pressure module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

NON-INVASIVE BLOOD PRESSURE (NIBP)
Oscilometric method.
Use: ADULT or NEONATE.
Measurement mode: AUTOMATIC or MANUAL.
Measure unit: mmHg.
Resolution:
- Pressure: 1 mmHg.
- Pulse rate: 1 1/min.
Transductor accuracy: ±3 mmHg.
Ranges:
- PEDIATRIC/ADULT
Systolic pressure: 25 to 265 mmHg.
Diastolic pressure: 12 to 220 mmHg.
Mean pressure: 18 to 245 mmHg.
Pulse rate: 40 to 240 1/min.
- NEONATE
Systolic pressure: 25 to 135 mmHg.
Diastolic pressure: 12 to 110 mmHg.
Mean pressure: 18 to 120 mmHg.
Pulse rate: 40 to 240 1/min.
Alarm limits of: Systolic pressure from 20 to 255 mmHg and off.
Diastolic pressure from 5 to 220 mmHg and off.
Display of the last 1440 measurements (48 hours, every 2 minutes).
Print-out of the measurements in table form.
Manual or automatic start of the measurement at programmable intervals of 2, 3, 4, 5, 10, 15, 30, 60 and 90 minutes.
Protections:
Double protection from over-pressure.
Over-pressure of 300 mmHg + 20 mmHg for the Adult mode.
Over-pressure of 150 mmHg + 15 mmHg for the Neonate mode.
Protection for exceeding time of measurement.

ACCESSORIES
Reusable cuff for NIBP (size to choice), quantity 1.
Silicone hose for NIBP,3m long, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Mainstream Capnography module for Multiparameter Patient Monitor LCD
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

MAINSTREAM CAPNOGRAPHY
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: ±2 mmHg from 0 to 40 mmHg.
±5% of reading from 41 to 70 mmHg.
Resolution: 1 mmHg.
Calibration: only zero (room air).
Compensation for temperature and atmospheric pressure, O2 y N2O.
Warm-up time <15s, to start measuring, within 2 minutes to obtain values consistent with the specifications.
Waveform response time: less than 60ms.

ACCESSORIES
Reusable airway adapter for Mainstream Capnography sensor, quantity 1.
Mainstream capnography sensor, quantity 1.
Adapter cable for Mainstream Capnography sensor, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of Invasive Blood Pressure module
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

INVASIVE BLOOD PRESSURE (IBP)
Up to 2 channels of invasive blood pressure.
Simultaneous measurement of Systolic, Diastolic and Mean pressure.
Range: -30 to 300 mmHg.
Mode selection for Pressure Ranges: Automatic or Manual.
Mean Pressure alarm: minimum and maximum limits from -30 to 300 mmHg and off.
Label: ART, AoP, LVP, PAP, CVP, WDG, RAP, RVP, ICP, IAP and IEP.
Measure unit: mmHg.
CVP, ICP, IAP and IEP can measure in mmHg or cmH20.

ACCESSORIES
Pressure transducer adapter cable (DB9/G) to BD transducer, quantity 1 or 2 (according to the added channels.).
Pressure transducer without adaptation B & D DTX plus TNF-R disposable, quantity 1 or 2 (according to the added channels.).
Derivation box for parameters of Pressure 1, Pressure 2 and/or FiO2 with DB9M, quantity 1 (only for two temperature channels installed).

The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.
Aggregate of FiO2 module for LCD Multiparametric Monitor
If you are interested in buying the module, we suggest that you send us the equipment serial number beforehand to ensure compatibility and verify that the module can be added to your equipment. When purchasing this module you must send the equipment to the factory to make the corresponding modifications.

RECORDER
Hotkey to record command.
High resolution thermal array printer.
Recorder speed: 25 mm/s.
Recorded in real time up to 2 selectable waveforms between ECG, RESP, IBP, SpO2 and CO2 waveform.
Prints the table of cardiac output measurement and the waveform of blood temperature, during the injected.
Prints the header with date and time.
Print values of Sweep Speed, Lead, Gain, Respiratory Rate, Heart Rate, Systolic, Diastolic and Mean Pressure, SpO2 and Pulse Rate, EtCO2, FiCO2 and Respiratory Rate (CO2), according recorded waveform.

SIDESTREAM CAPNOGRAPHY WITH ANESTHETIC GASES AND O2 MEASUREMENT
Measurement of EtCO2, FiCO2 and Respiratory Rate.
Range: CO2, from 0 to 100 mmHg (0% to 13%).
Respiratory Rate, 4 to 150 1/min.
Accuracy: CO2, ±3%ABS.
Resolution: CO2, 1 mmHg.
Respiratory Rate, 1 1/min.
Alarm: FiCO2, EtCO2 minimum and maximum, 0 to 100 mmHg and off.
Respiratory Rate minimum and maximum, 0 to 150 1/min and off.
Measurement of expired and inspired O2: from 0% to 100%, Resolution: 1%.
Measurement of N2 O: from 0% to 100%.
Automatic detection and measurement of up two anesthetic gases: Halothane, Enflurane,
Isoflurane, Sevoflurane and Desflurane.
- Range: 0% to 30%.
- Accuracy: ±8%REL.
- Resolution: 0.1%.
Flowrate: 70 to 120 ml/min for neonatal patients.
120 to 250 ml/min for adult patients.

ACCESSORIES
Tubing straight airway adapter for sidestream capnography Feas Electrónica, quantity 2.
2.4 m CO2 samplig lines for sidestream capnography Feas Electrónica, quantity 2.
Water trap for use in sidestream capnography with anesthetic gases, quantity 2.
Galvanix oxygen sensor, quantity 1.
Roll of Thermal paper of 50mm x 25m, quantity 1.



The images shown are for illustrative purposes only and may differ from the actual product. Specifications are subject to change without notice.